Miele G 7835 Operation, Power switch, Turning on, To change the operating level

Page 26

Operation

Power switch

(with "emergency cut-off function") set to I-ON.

When switching on, selecting or changing the operating level there are four operating levels available:

A = Fixed program / Programs with free access

B = Free program selection

C = AWK – Automatic mobile unit recognition (program selection via mobile unit coding)

D = Programming / free program selection / change code (see "Programming manual")

Turning on

^Open the water valves (if turned off).

^Press the ON/OFF I-0button.

In operating levels A, B and D the most recently selected PROGRAM NAME appears and in operating level C "AUTOMATIC MOBILE UNIT RECOGNITION" is displayed.

To change the operating level

^Press 1 and 2 at the same time. Operating levels A B C D will appear in the display.

^Select the operating level you want using the 1 or 2 keys.

^Press 6 to confirm selection.

^Enter code when requested by the display.

The code is set by default to >0000<.

^Press the "Start" button 6. [0000] appears.

^Enter numbers using the 4 and 3 keys.

^Select number position with the 1 or 2 key.

^To confirm code press 6.

If you enter it incorrectly: FALSE CODE, ENTER AGAIN will appear in the display.

^Close the door.

Selecting or changing your own code

The factory set code can be changed (see "Programming Manual

-System function"). Code 1 for levels ABC Code 2 for levels ABCD

26

Image 26
Contents Laboratory glassware washer G Contents Contents Important Safety Instructions UseImportant Safety Instructions Important Safety Instructions Using accessories Disposal of an old applianceGuide to the machine Electronic controlsOn/Off button Cursor left Door switch h Start buttonDisplay Cursor rightGuide to the machine Opening the door Opening and closing the doorElectric door lock To close the doorWater softener Enter Water Hardness Setting the water softenerSelect Unit Softener CapacityFilling the salt reservoir Salt indicator Automatic mobile unit recognition AWK Mobile unit codingSetting mobile unit coding Mobile unit coding stripSet the program place coding Loading the machine Preparing the items for cleaningApplications Removing excess soilsApplications Spring adapter water connection Height adjustable top basketTo adjust the upper basket Example upper basket O 190/1 and lower basket ULaboratory glassware LG Injector unit 1/1 With connection to TAAdditional DOS modules optional Adding of liquid detergents and neutralizersPreparing the DOS dispensers Filling the containers with liquid cleaning agents External Dispensing systems Dispensing system maintenancePriming the liquid dispensing systems OptionalTurning on Power switchOperation To change the operating levelFree program selection Starting a programFixed program Automatic mobile unit recognition AWK Program sequenceTurning off Operating levels a or C To change or cancel a programOperating levels B or D Cancelling a program Serial interface Cleaning the coarse filter Cleaning and CareCleaning the filters in the wash cabinet Cleaning the fine, flat and micro-fine filters Cleaning the drain pump and non-return valve Tilt the locking clamp to the sideCleaning the exterior Cleaning the water inlet filtersCleaning the control panel Cleaning the filterOpen the door of the storage cabinet Drying unit TA Cleaning and careChanging the coarse filter Replacing the HEPA-Filter Frequently asked questions After sales service Page Installation Instructions Disposal of an old appliance Caring for the environmentDisposal of the packing materials Removing the lid if necessary InstallationLeveling the legs Protecting the countertop depending on modelPlumbing Water inletDI-Water connection Drainage Electrical connection This Appliance Must be GroundedRe-assembling the service panel Grounding the machineTechnical Data English MetricPage Page All rights reserved/3404