Miele G 7835 operating instructions Grounding the machine, Re-assembling the service panel

Page 48

Electrical connection

Grounding the machine

The machine must only be operated with the voltage, frequency and fusing shown on the data plate located on the rear of the machine, and on the plinth (behind the service panel).

The conversion diagram and the wiring diagram is secured to the inner side of the service panel.

Remove the service panel and plinth

,Disconnect the machine from the main electrical supply.

^Remove the fixing screws, a, from the service panel.

^Take hold of the service panel at both sides and pull upwards.

^Unscrew plinth facing (screws b).

^Remove plastic protective cap.

Re-assembling the service panel

^Replace the plastic protective cap, plinth facing and service panel in the reverse order.

^See the supplied installation diagram.

48

Image 48
Contents Laboratory glassware washer G Contents Contents Important Safety Instructions UseImportant Safety Instructions Important Safety Instructions Using accessories Disposal of an old applianceGuide to the machine Electronic controlsDoor switch h Start button DisplayOn/Off button Cursor left Cursor rightGuide to the machine Opening and closing the door Electric door lockOpening the door To close the doorWater softener Setting the water softener Select UnitEnter Water Hardness Softener CapacityFilling the salt reservoir Salt indicator Automatic mobile unit recognition AWK Mobile unit codingSetting mobile unit coding Mobile unit coding stripSet the program place coding Preparing the items for cleaning ApplicationsLoading the machine Removing excess soilsApplications Height adjustable top basket To adjust the upper basketSpring adapter water connection Example upper basket O 190/1 and lower basket ULaboratory glassware LG Injector unit 1/1 With connection to TAAdding of liquid detergents and neutralizers Preparing the DOS dispensersAdditional DOS modules optional Filling the containers with liquid cleaning agents Dispensing system maintenance Priming the liquid dispensing systemsExternal Dispensing systems OptionalPower switch OperationTurning on To change the operating levelStarting a program Fixed programFree program selection Program sequence Turning offAutomatic mobile unit recognition AWK To change or cancel a program Operating levels B or DOperating levels a or C Cancelling a program Serial interface Cleaning and Care Cleaning the filters in the wash cabinetCleaning the coarse filter Cleaning the fine, flat and micro-fine filters Cleaning the drain pump and non-return valve Tilt the locking clamp to the sideCleaning the water inlet filters Cleaning the control panelCleaning the exterior Cleaning the filterDrying unit TA Cleaning and care Changing the coarse filterOpen the door of the storage cabinet Replacing the HEPA-Filter Frequently asked questions After sales service Page Installation Instructions Caring for the environment Disposal of the packing materialsDisposal of an old appliance Installation Leveling the legsRemoving the lid if necessary Protecting the countertop depending on modelPlumbing Water inletDI-Water connection Drainage Electrical connection This Appliance Must be GroundedRe-assembling the service panel Grounding the machineTechnical Data English MetricPage Page All rights reserved/3404