Miele PT 7136 PLUS Select a program, Select Low temp. and/or Timer, Starting a program

Page 13

Use

3. Select a program

Two program selection possibilities:

￿Select a "Favorite" by pressing the respective direct select button.

or

￿Select from the "Program selection" menu by turning the jog shuttle.

4.Select "Low temp." and/or "Timer"

￿If desired select "Low temp." and/or "Timer" from the respective submenus.

Note:

The displayed duration (remaining time) can vary with every new program selection.

5.Insert coins (if operated by coin mechanism)

￿If a coin mechanism operates the machine, please regard the displayed request to pay.

If the door is opened after the program has started or if the program is canceled the credit is lost.

6. Starting a program

"Start" flashes when the program can be started.

￿Press the "Start" button. The "Start" button lights.

The display shows "Program start" and then "Drying" with the program duration.

The drying levels are displayed, e.g. machine iron, hand iron, etc.

￿Press one of the following buttons during the running program:

Button ￿ "Timer"

The time of day and the approximate program end is displayed.

Button ￿ "Save"

The currently running program can be saved as a "Favorite".

Button ￿ "Cancellation"

To cancel the currently running program.

13

Image 13
Contents Operating and Installation manual Vented Dryer PT 7136 Plus Contents Contents Important Safety Instructions Important Safety Instructions Save These Instructions Control panel Guide to the dryerMain menu Display functionJog shuttle Program selection possibilityMenu Program selection SettingsBasic menu of a drying program Welcome screen Before using for the first time Language Set the time of dayFabric care labels UseDrying tips Load the laundry Sort the laundrySelect a program Select Low temp. and/or TimerInsert coins if operated by coin mechanism Starting a programAt the end of a program Cleaning and care hintsRemaining time Before the end of a programCoin mechanism Canceling a programAdding/removing laundry during a drying program Continue dryingProgram guide Smoothing Woollen handcareCool air Warm airNormal, Hand iron JeansShirts ProofingSelect the submenu Timer TimerStarting the timer function Canceling the timerSelecting/Changing a Favorite FavoritesBasic menu Program Warm air, Cool air Drying level programsOther programs Saving a Favorite Low tempAssigning a direct select button Cleaning the lint filter Cleaning and CareRemoving the lint filter Disassembling the lint filterClean the lint filters wet Clean the lint filters dryInserting the lint filter Cleaning the exterior and the control panelCheck and fault messages in the display Frequently asked questionsWhat if Possible cause Solution Program What if Possible cause Solution At the end of aAppears Other faults Condensed water What if Possible fault Solution What if there isDrum? Items madeStart indicator What if Possible cause Solution Program cannotBe started, Display remainsChanging the light bulb Optional accessories After sales serviceInstallation Instructions Important Safety Instructions Save These Instructions Front view InstallationSide view Rear view Top view Washer/ Dryer Stack Installation on a cement base Coin mechanism Transporting the dryer to the installation site InstallationLevel the dryer Electrical connection General notes Installation of exhaust ventingHow to calculate the effective duct length Tips about the ductwork Additional duct lengths 4 rigid pipe only Length Changing the position of the exhaust connection Determining the position of the exhaust connectionWall connection with rigid pipe Window connectionChimney connection Dryer top view Direct wall connectionCollective exhaust duct Technical Data Disposal of the packing materials Caring for the environmentDisposal of an appliance Menu Settings To adjust standard settings Opening the menu Settings SettingsSelecting Settings Leaving the Settings menuAnti-crease Time of day LanguageOff NormalDelivery status 0 minutes normal cooling down phase Not during current program default settingContrast/Brightness StandbyEntering the code Settings Supervisor levelSupervisor level Sort languagesLanguage entry Drying levels TimerNormal Factory default Light Cleaning the airways Cleaning the lint filtersDisplay the residual moisture as a percentage Cool air freePage Page Page All rights reserved Nr 975 240