Miele PT 7136 PLUS installation manual Additional duct lengths 4 rigid pipe only

Page 44

Installation of exhaust venting

Additional duct lengths (4" rigid pipe only)

Type of bend

 

Radius

Additional duct length

 

 

 

 

 

 

ft

 

cm

ft

 

cm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flexible metal duct

 

 

 

 

 

 

– 3’ 3" (1 m) straight

 

 

 

5’ 11"

 

180

45° angle

 

 

10"

 

25

4’ 11"

 

150

90° angle

 

 

10"

 

25

8’ 2"

 

250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Smooth metal duct

 

 

 

 

 

 

– 3’ 3" (1 m) straight

 

 

 

3’ 3"

 

100

45° angle

 

 

 

 

10"

 

25

1’ 11"

 

60

90° angle

 

 

 

 

10"

 

25

2’ 7"

 

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Elbow 90° sharp

 

 

 

 

 

7’ 6"

 

230

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Concertina bend

 

 

 

 

 

 

 

 

90° angle

 

 

8"

 

20

2’ 4"

 

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wall vent or window vent

 

 

 

 

 

 

with louvers

 

 

 

12’ 5"

 

380

with flap

 

 

 

4’ 11"

 

150

 

 

 

 

 

 

 

 

 

 

 

Exhaust connection

 

 

 

 

 

 

– left or right side

 

 

 

3’ 3"

 

100

 

 

 

 

 

 

 

 

 

 

 

 

44

Image 44
Contents Operating and Installation manual Vented Dryer PT 7136 Plus Contents Contents Important Safety Instructions Important Safety Instructions Save These Instructions Guide to the dryer Control panelDisplay function Main menuJog shuttle Program selection possibilityBasic menu of a drying program SettingsMenu Program selection Before using for the first time Welcome screenLanguage Set the time of dayDrying tips UseFabric care labels Sort the laundry Load the laundrySelect Low temp. and/or Timer Select a programInsert coins if operated by coin mechanism Starting a programCleaning and care hints At the end of a programRemaining time Before the end of a programCanceling a program Coin mechanismAdding/removing laundry during a drying program Continue dryingProgram guide Woollen handcare SmoothingCool air Warm airJeans Normal, Hand ironShirts ProofingTimer Select the submenu TimerStarting the timer function Canceling the timerBasic menu FavoritesSelecting/Changing a Favorite Other programs Drying level programsProgram Warm air, Cool air Assigning a direct select button Low tempSaving a Favorite Cleaning and Care Cleaning the lint filterRemoving the lint filter Disassembling the lint filterClean the lint filters dry Clean the lint filters wetCleaning the exterior and the control panel Inserting the lint filterWhat if Possible cause Solution Frequently asked questionsCheck and fault messages in the display Appears What if Possible cause Solution At the end of aProgram Other faults What if Possible fault Solution What if there is Condensed waterDrum? Items madeWhat if Possible cause Solution Program cannot Start indicatorBe started, Display remainsChanging the light bulb After sales service Optional accessoriesInstallation Instructions Important Safety Instructions Save These Instructions Installation Front viewSide view Rear view Top view Washer/ Dryer Stack Installation on a cement base Coin mechanism Level the dryer InstallationTransporting the dryer to the installation site Electrical connection Installation of exhaust venting General notesHow to calculate the effective duct length Tips about the ductwork Additional duct lengths 4 rigid pipe only Length Determining the position of the exhaust connection Changing the position of the exhaust connectionWindow connection Wall connection with rigid pipeChimney connection Direct wall connection Dryer top viewCollective exhaust duct Technical Data Disposal of an appliance Caring for the environmentDisposal of the packing materials Menu Settings To adjust standard settings Settings Opening the menu SettingsSelecting Settings Leaving the Settings menuLanguage Anti-crease Time of dayOff NormalNot during current program default setting Delivery status 0 minutes normal cooling down phaseContrast/Brightness StandbySettings Supervisor level Entering the codeSort languages Supervisor levelTimer Language entry Drying levelsCleaning the airways Cleaning the lint filters Normal Factory default LightDisplay the residual moisture as a percentage Cool air freePage Page Page All rights reserved Nr 975 240