Settings ￿

Contrast/Brightness

Display contrast and brightness can be adjusted in 10 levels.

The bar shows the selected level.

Standby

The display goes into standby mode after 10 minutes and the "Start" button flashes slowly to save energy.

on

Standby is turned on:

when no program is selected.

after pressing the "Start" button.

at the end of a program.

not during current program (default setting)

Standby is turned on:

– when no program is selected.

Pressing any button or turning the jog shuttle turns the display on again.

off

The display stays turned on.

Lengthening the cooling time

The cooling phase can be lengthened before the program is started. The laundry will be cooled.

The bar shows the selected level.

Delivery status: 0 minutes (normal cooling down phase).

The program duration is extended respectively.

The cooling time cannot be extended in the programs "Warm air, Cool air, Woollen handcare, Smoothing".

56

Image 56
Contents Operating and Installation manual Vented Dryer PT 7136 Plus Contents Contents Important Safety Instructions Important Safety Instructions Save These Instructions Guide to the dryer Control panelDisplay function Main menuJog shuttle Program selection possibilityBasic menu of a drying program SettingsMenu Program selection Before using for the first time Welcome screenLanguage Set the time of dayDrying tips UseFabric care labels Sort the laundry Load the laundrySelect Low temp. and/or Timer Select a programInsert coins if operated by coin mechanism Starting a programCleaning and care hints At the end of a programRemaining time Before the end of a programCanceling a program Coin mechanismAdding/removing laundry during a drying program Continue dryingProgram guide Woollen handcare SmoothingCool air Warm airJeans Normal, Hand ironShirts ProofingTimer Select the submenu TimerStarting the timer function Canceling the timerBasic menu FavoritesSelecting/Changing a Favorite Other programs Drying level programsProgram Warm air, Cool air Assigning a direct select button Low tempSaving a Favorite Cleaning and Care Cleaning the lint filterRemoving the lint filter Disassembling the lint filterClean the lint filters dry Clean the lint filters wetCleaning the exterior and the control panel Inserting the lint filterWhat if Possible cause Solution Frequently asked questionsCheck and fault messages in the display Appears What if Possible cause Solution At the end of aProgram Other faults What if Possible fault Solution What if there is Condensed waterDrum? Items madeWhat if Possible cause Solution Program cannot Start indicatorBe started, Display remainsChanging the light bulb After sales service Optional accessoriesInstallation Instructions Important Safety Instructions Save These Instructions Installation Front viewSide view Rear view Top view Washer/ Dryer Stack Installation on a cement base Coin mechanism Level the dryer InstallationTransporting the dryer to the installation site Electrical connection Installation of exhaust venting General notesHow to calculate the effective duct length Tips about the ductwork Additional duct lengths 4 rigid pipe only Length Determining the position of the exhaust connection Changing the position of the exhaust connectionWindow connection Wall connection with rigid pipeChimney connection Direct wall connection Dryer top viewCollective exhaust duct Technical Data Disposal of an appliance Caring for the environmentDisposal of the packing materials Menu Settings To adjust standard settings Settings Opening the menu SettingsSelecting Settings Leaving the Settings menuLanguage Anti-crease Time of dayOff NormalNot during current program default setting Delivery status 0 minutes normal cooling down phaseContrast/Brightness StandbySettings Supervisor level Entering the codeSort languages Supervisor levelTimer Language entry Drying levelsCleaning the airways Cleaning the lint filters Normal Factory default LightDisplay the residual moisture as a percentage Cool air freePage Page Page All rights reserved Nr 975 240