Basic Installation/Operation
Table 2 (continued)
UWAV Pocket Hardmount General Specifications
Specifications |
|
| 35 | 60 | 80 | 100 | 125 | |
|
|
|
|
|
|
| ||
Drive Train Information |
|
|
|
|
| |||
|
|
|
|
|
| |||
Number of motors in drive train |
| 1 | 1 | 1 | 1 | 1 | ||
|
|
|
|
|
|
|
| |
Drive motor power, hp (kW) |
|
| 2.3 (1.7) | 2.9 (2.2) | 5.0 (3.7) | 5.0 (3.7) | 7.5 (5.6) | |
|
|
|
|
|
| |||
Cylinder Speeds / Centrifugal Force Data |
|
|
|
| ||||
|
|
|
|
|
|
|
| |
1/2 Wash/reverse, RPM / g |
|
| 26 / .25 | 26 / .31 | 26 / .35 | 26 / .35 | 26 / .40 | |
|
|
|
|
|
|
|
| |
Wash/reverse, RPM / g |
|
| 42 / .66 | 40 / .73 | 40 / .82 | 40 / .82 | 37 / .82 | |
|
|
|
|
|
|
|
| |
Distribution, RPM / g |
|
| 83 / 2.57 | 71 / 2.29 | 73 / 2.57 | 70 / 2.50 | 62 / 2.29 | |
|
|
|
|
|
|
|
| |
High extract 1, RPM / g |
|
| 329 / 40 | 297 / 40 | 280 / 40 | 280 / 40 | 260 / 40 | |
|
|
|
|
|
|
|
| |
High extract 2, RPM / g |
|
| 534 / 106 | 483 / 106 | 456 / 106 | 456 / 106 | 422 / 106 | |
|
|
|
|
|
|
|
| |
High extract 3, RPM / g |
|
| 656 / 160 | 594 / 160 | 560 / 160 | 560 / 160 | 518/ 160 | |
|
|
|
|
|
|
|
| |
Balance Detection |
|
|
|
|
|
|
| |
|
|
|
|
|
| |||
Vibration safety switch installed |
| N/A | STD | STD | STD | STD | ||
|
|
|
|
|
|
| ||
Safety switch gap setting, in. (mm)* |
| N/A | .25 (.010) | .25 (.010) | .25 (.010) | .20 (.008) | ||
|
|
|
| .20 (.008) GO | .20 (.008) GO | .20 (.008) GO | .15 (.006) GO | |
|
|
|
|
| ||||
Direct Steam Heating (Optional) |
|
|
|
| ||||
|
|
|
|
|
| |||
Steam inlet connection size, in. (mm) |
| .5 (13) | .5 (13) | .5 (13) | .5 (13) | .75 (19) | ||
|
|
|
|
|
|
|
| |
Number of steam inlets |
|
| 1 | 1 | 1 | 1 | 1 | |
|
|
|
|
|
|
|
| |
Steam required to raise bath |
| LOW |
| 2.1 (1.5) | 3.3 (2.4) | 4.6 (3.3) | 5.7 (4.1) | 6.7 (4.9) |
temperature, |
|
|
|
|
|
|
|
|
| MED |
| 2.3 (1.7) | 3.7 (2.6) | 5.2 (3.8) | 6.5 (4.7) | 7.8 (5.6) | |
10°F, lb. (10°C, kg) |
|
| ||||||
|
| HIGH |
| 2.7 (1.9) | 4.1 (2.9) | 6.1 (4.4) | 7.6 (5.5) | 9.1 (6.6) |
|
|
|
|
|
|
|
| |
Average consumption per cycle, bhp |
| 1.4 (21.4) | 2.1 (33.4) | 3.1 (48.4) | 3.8 (60.4) | 4.6 (72.0) | ||
(kg) |
|
|
|
|
|
|
| |
Electrical Heating (Optional) |
|
|
|
|
| |||
|
|
|
|
|
| |||
Total electrical heating capacity, kW |
| 15.6 | 25.2 | 37.8 | 37.8 | 50.4 | ||
|
|
|
|
|
|
| ||
Number of electrical heating elements |
| 6 | 6 | 9 | 9 | 12 | ||
|
|
|
|
|
|
| ||
Electrical heating element size, kW |
| 2.6 | 4.2 | 4.2 | 4.2 | 4.2 | ||
|
|
|
|
|
|
|
| |
Time required to raise bath |
| LOW |
| 2.4 (3.6) | 2.4 (3.7) | 2.2 (3.4) | 2.8 (4.2) | 2.5 (3.8) |
temperature, |
|
|
|
|
|
|
|
|
| MED |
| 2.7 (4.1) | 2.7 (4.1) | 2.5 (3.9) | 3.2 (4.8) | 2.9 (4.4) | |
10°F, min. (10°C, min.) |
|
| ||||||
|
| HIGH |
| 3.1 (4.7) | 3.0 (4.6) | 3.0 (4.5) | 3.7 (5.6) | 3.4 (5.1) |
|
|
|
|
|
|
|
|
|
* Gap setting should be made with
Table 2
10 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232156 |