Alliance Laundry Systems P232156R9 manual UW 2 Speed Models

Page 28

Basic Installation/Operation

 

 

1

 

 

 

 

2

 

 

 

3

 

 

 

 

4

 

 

 

 

F

 

 

 

 

 

 

 

E

 

C

 

 

 

 

A (BASE)

 

 

G (BASE)

 

B (OVERALL)

5

 

D (OVERALL)

 

 

 

 

 

 

 

 

6

 

 

 

 

7

 

I

8

 

 

 

 

H

 

 

 

 

 

 

PHM388N

 

 

UW 2 Speed Models

 

 

 

 

 

P032I

1

Supply Valve Box

 

5

Water Inlet Valves

2

Supply Dispenser

 

6

Power Input Area (Inside)

3

Door Handle

 

7

Steam Connection (Optional)

4

Spray Rinse Nozzle (2 Speed, P-Control Models

8

Drain

 

Only)

 

 

 

Figure 6

26

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F232156

Image 28
Contents Washer-Extractors Page Contents Explanation of Safety Messages Important Safety InstructionsBasic Installation/Operation Safety Decals Operator Safety General Specifications Specifications 100 125 150 Overall DimensionsWeight And Shipping Information UW UniLinc and M30 Control ModelsDoor Opening Information Drive Train InformationCylinder Speeds / Centrifugal Force Data Balance DetectionElectrical Heating Optional UW A-Control, Variable-Speed Models Power ConsumptionWater Consumption MED Uwpv Models Specifications 100 125 150 Overall Dimensions UW P-Control, Variable-Speed ModelsWash/reverse, RPM / g Distribution, RPM / g UW 2 Speed Models UW35 UW60 Overall Dimensions Domestic shipping volume, ft.3 m3Cylinder Speeds/Centrifugal Force Data UW 3 Speed Models UW35 UW60 Overall Dimensions UW 3 Speed Models with P-Control or597 561 UniLinc and M30 Control Models Crush hazard100 125 150 911 14 UW150TV Uwav Models Models UW 35 Uwpv Pocket Hardmount Machine Dimensions Refer to and Figure Uwpv Models UW35PV UW125PV UW150PV 55.5 1410 64.5 1638 30.5 775 914 203 15.5 394 43.88 UW 2 Speed Models UW 3 Speed Models with P-Control or S-Control UW 3 Speed Models Operation UW Models With UniLinc ControlFor Technical Service Distributor ABC UW Models With M30 Control Cycle Number Cycle Name PHM784N UW Models with S-Control Cycle is complete when display reads donE Pre-Operating Instructions UW Models with P-ControlOperating Instructions UW150 Models SW025 UW Models with A-Control Basic Installation/Operation UW Models with B-Control Basic Installation/Operation Disposal of Unit