Basic Installation/Operation
Table 3 (continued)
UWPV Models
Specifications | 35 | 60 | 80 | 100 | 125 | 150 | ||
|
|
|
|
|
|
| ||
Cylinder Speeds / Centrifugal Force Data |
|
|
|
| ||||
|
|
|
|
|
|
| ||
1/2 Wash/reverse, RPM / g | 26 / .25 | 26 / .31 | 26 / .35 | 26 / .35 | 26 / .40 | 23 / .31 | ||
|
|
|
|
|
|
|
| |
Wash/reverse, RPM / g |
| 42 / .66 | 40 / .73 | 40 / .82 | 40 / .82 | 37 / .82 | 36 / 0.8 | |
|
|
|
|
|
|
|
| |
Distribution, RPM / g |
| 83 / 2.57 | 71 / 2.29 | 73 / 2.57 | 70 / 2.50 | 62 / 2.29 | 61 / 2.29 | |
|
|
|
|
|
|
|
| |
Medium extract, RPM / g |
| 325 / 39 | 305 / 42 | 325 / 54 | 325 / 54 | 260 / 40 | 262 / 42 | |
|
|
|
|
|
|
|
| |
High extract l, RPM / g |
| 474 / 84 | 435 / 86 | 408 / 85 | 408 / 85 | 380 / 86 | 417 / 106 | |
*Design U6 models |
|
|
|
|
|
|
| |
| 533 / 106 | 483 / 106 | 456 / 106 | 456 / 106 | N/A | 417 / 106 | ||
|
| |||||||
|
|
|
|
|
|
|
| |
High extract 2, RPM / g |
| 610 / 139 | 555 / 140 | 523 / 140 | 523 / 140 | 485 / 140 | 512 / 160 | |
|
|
|
|
|
|
|
| |
High extract 3, RPM / g |
| 795 / 235 | 720 / 235 | 671 / 230 | 601 / 184 | 534 / 170 | 573 / 200 | |
*Design U6 models |
|
|
|
|
|
|
| |
| 897 / 308 | 813 / 300 | 767 / 300 | 767 / 300 | 580 / 200 | 701 / 300 | ||
|
| |||||||
|
|
|
|
|
|
| ||
Balance Detection |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
Vibration switch installed |
| STD | STD | STD | STD | STD | STD | |
|
|
|
|
|
|
| ||
Switch gap setting, in. (mm)** | .20 (.008) | .25 (.010) | .25 (.010) | .25 (.010) | .20 (.008) | .30 (.014) | ||
|
| .15 (.006) GO | .20 (.008) GO | .20 (.008) GO | .20 (.008) GO | .15 (.006) GO | .33 (.013) GO | |
Direct Steam Heating (Optional) |
|
|
|
|
| |||
|
|
|
|
|
|
| ||
Steam inlet connection size, | 1/2 (13) | 1/2 (13) | 1/2 (13) | 1/2 (13) | 3/4 (19) | 3/4 (19) | ||
in. (mm) |
| |||||||
|
|
|
|
|
|
| ||
Number of steam inlets |
| 1 | 1 | 1 | 1 | 1 | 1 | |
|
|
|
|
|
|
|
| |
Steam required to | LOW | 2.1 (1.5) | 3.3 (2.4) | 4.6 (3.3) | 5.7 (4.1) | 6.7 (4.9) | 8.3 (6.0) | |
raise bath temperature, |
|
|
|
|
|
|
| |
MED | 2.3 (1.7) | 3.7 (2.6) | 5.2 (3.8) | 6.5 (4.7) | 7.8 (5.6) | 9.5 (6.9) | ||
10°F, lb. (10°C, kg) | ||||||||
| HIGH | 2.7 (1.9) | 4.1 (2.9) | 6.1 (4.4) | 7.6 (5.5) | 9.1 (6.6) | 11.1 (8.0) | |
|
|
|
|
|
|
|
| |
Average consumption per cycle, | 1.4 (21.4) | 2.1 (33.4) | 3.1 (48.4) | 3.8 (60.4) | 4.6 (72.0) | 5.8 (91.0) | ||
bhp (kg) |
| |||||||
|
|
|
|
|
|
| ||
Electrical Heating (Optional) |
|
|
|
|
| |||
|
|
|
|
|
|
| ||
Total electrical heating capacity, | 15.6 | 25.2 | 37.8 | 37.8 | 50.4 | N/A | ||
kW |
| |||||||
|
|
|
|
|
|
| ||
Number of electrical heating | 6 | 6 | 9 | 9 | 12 | N/A | ||
elements |
| |||||||
|
|
|
|
|
|
| ||
Electrical heating element size, | 2.6 | 4.2 | 4.2 | 4.2 | 4.2 | N/A | ||
kW |
| |||||||
|
|
|
|
|
|
| ||
Time required to | LOW | 2.4 (3.6) | 2.4 (3.7) | 2.2 (3.4) | 2.8 (4.2) | 2.5 (3.8) | N/A | |
raise bath temperature, |
|
|
|
|
|
|
| |
MED | 2.7 (4.1) | 2.7 (4.1) | 2.5 (3.9) | 3.2 (4.8) | 2.9 (4.4) | N/A | ||
10°F, min. (5°C, min.) | ||||||||
| HIGH | 3.1 (4.7) | 3.0 (4.6) | 3.0 (4.5) | 3.7 (5.6) | 3.4 (5.1) | N/A | |
|
|
|
|
|
|
|
|
*Refer to Figure 4 and Figure 5, and serial number decal on machine to determine design series.
**Gap setting should be made with
N/A = Not Applicable
Table 3
12 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232156 |