Alliance Laundry Systems P232156R9 manual UW 2 Speed Models UW35 UW60 Overall Dimensions

Page 15

Basic Installation/Operation

UW 2 Speed Models with P-Control,

.

 

S-Control, Mechanical Timer or B-Control

 

 

Refer to Table 4.

 

 

 

 

 

 

 

 

 

UW 2 Speed Models

 

 

 

 

 

 

 

 

 

UW35

UW60

 

 

 

 

 

Overall Dimensions

 

 

 

 

 

 

 

 

 

Overall width, in. (mm)

 

 

32-1/2 (826)

36-5/8 (930)

 

 

 

 

 

Overall height, in. (mm)

 

 

55-1/2 (1410)

64-1/2 (1638)

 

 

 

 

 

Overall depth, in. (mm)

 

 

38-1/4 (972)

45 (1143)

 

 

 

 

 

Weight and Shipping Information

 

 

 

 

 

 

 

 

 

Net weight, lb. (kg)

 

 

750 (341)

1136 (515)

 

 

 

 

 

Basket/shaft weight, lb. (kg)

 

 

74 (34)

200 (92)

 

 

 

 

 

Domestic shipping weight, lb. (kg)

 

 

810 (367)

1175 (533)

 

 

 

 

 

Domestic shipping volume, ft.3 (m3)

 

 

66 (1.9)

84 (2.4)

Domestic shipping dimensions W x D x H, mm (in.)

 

 

38 x 47 x 64

40 x 49 x 74-1/2

 

 

 

(970 x 1200 x 1630)

(1016 x 1245 x 1892)

Export shipping weight, lb. (kg)

 

 

910 (413)

1300 (590)

 

 

 

 

 

Export shipping volume, ft.3 (m3)

 

 

78 (2.2)

96 (2.7)

Export shipping dimensions W x D x H, in. (mm)

 

 

41 x 50 x 65-1/2

43 x 52-1/8 x 74-1/2

 

 

 

(1050 x 1280 x 1670)

(1092 x 1324 x 1892)

Wash Cylinder Information

 

 

 

 

 

 

 

 

 

Cylinder diameter, in. (mm)

 

 

26-1/4 667

32 (813)

 

 

 

 

 

Cylinder depth, in. (mm)

 

 

18-3/8 (467)

20 (508)

 

 

 

 

 

Cylinder volume, ft.3 (l)

 

 

5.76 (163)

9.31 (264)

Perforation size, in. (mm)

 

 

3/16 (4.8)

3/16 (4.8)

 

 

 

 

 

Perforation open area, %

 

 

18

22

 

 

 

 

 

Door Opening Information

 

 

 

 

 

 

 

 

 

Door opening size, in. (mm)

 

 

14-11/32 (364)

17-1/2 (445)

 

 

 

 

 

Height of door bottom above floor, in. (mm)

 

 

23-3/4 (603)

28-1/4 (718)

 

 

 

 

 

Water Consumption*

 

 

 

 

Average water consumption per cycle, gal. (l)

HOT

 

45 (170)

61 (231)

 

 

 

 

 

 

COLD

 

24 (91)

29 (110)

 

 

 

 

 

Average hot water used per hour, gal. (l)

 

 

78 (295)

102 (386)

 

 

 

 

 

Power Consumption

 

 

 

 

 

 

 

 

 

Average power used per cycle, kWh

 

 

0.3

0.47

 

 

 

 

 

Max. nominal sound emission, dBA

 

 

72

81

 

 

 

 

 

Average HVAC load, Btu/hr (kcal/hr)

 

 

600 (151)

875 (220)

 

 

 

 

 

*For P and S controls only. M control has no spray rinse.

Table 4 (continued)

F232156

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

13

Image 15
Contents Washer-Extractors Page Contents Important Safety Instructions Explanation of Safety MessagesBasic Installation/Operation Safety Decals Operator Safety UW UniLinc and M30 Control Models General SpecificationsSpecifications 100 125 150 Overall Dimensions Weight And Shipping InformationBalance Detection Door Opening InformationDrive Train Information Cylinder Speeds / Centrifugal Force DataElectrical Heating Optional Power Consumption UW A-Control, Variable-Speed ModelsWater Consumption MED UW P-Control, Variable-Speed Models Uwpv Models Specifications 100 125 150 Overall DimensionsWash/reverse, RPM / g Distribution, RPM / g Domestic shipping volume, ft.3 m3 UW 2 Speed Models UW35 UW60 Overall DimensionsCylinder Speeds/Centrifugal Force Data UW 3 Speed Models with P-Control or UW 3 Speed Models UW35 UW60 Overall Dimensions597 561 Crush hazard UniLinc and M30 Control Models100 125 150 911 14 UW150TV Uwav Models Models UW 35 Uwpv Models Uwpv Pocket Hardmount Machine Dimensions Refer to and FigureUW35PV UW125PV UW150PV 55.5 1410 64.5 1638 30.5 775 914 203 15.5 394 43.88 UW 2 Speed Models UW 3 Speed Models with P-Control or S-Control UW 3 Speed Models UW Models With UniLinc Control OperationFor Technical Service Distributor ABC UW Models With M30 Control Cycle Number Cycle Name PHM784N UW Models with S-Control Cycle is complete when display reads donE UW Models with P-Control Pre-Operating InstructionsOperating Instructions UW150 Models SW025 UW Models with A-Control Basic Installation/Operation UW Models with B-Control Basic Installation/Operation Disposal of Unit