Basic Installation/Operation
Table 5 (continued)
UW 3 Speed Models
|
| UW35 | UW60 | |||
|
|
|
|
|
| |
Power Consumption |
|
|
|
|
| |
|
|
|
| |||
Average power used per cycle, kWh |
| 0.24 | 0.47 | |||
|
|
|
| |||
Max nominal sound emission, dBA |
| 72 | 81 | |||
|
|
|
|
|
| |
Average HVAC load, Btu/hr (kcal/hr) |
| 625 | (157) | 875 | (220) | |
|
|
|
|
|
| |
Drive Train Information |
|
|
|
|
| |
|
|
|
|
|
| |
Number of motors in drive train |
|
| 2 |
| 2 | |
|
|
|
|
|
| |
Wash/reverse motor power, hp (kW) |
| 0.4 | (0.3) | 0.9 | (0.7) | |
|
|
|
|
|
| |
Distribution motor power, hp (kW) |
| 0.45 | (0.34) | 1.0 | (0.8) | |
|
|
|
|
| ||
High extract motor power, hp (kW) |
| 3 (2.2) | 3.5 | (2.6) | ||
|
|
|
|
| ||
Cylinder Speeds/Centrifugal Force Data |
|
|
|
| ||
|
|
|
| |||
Wash/reverse speed, RPM / g |
| 45 / 0.76 | 42 / 0.80 | |||
|
|
|
| |||
Distribution speed, RPM / g |
| 75 / 2.10 | 67 / 2.04 | |||
|
|
|
| |||
High extract speed, RPM / g |
| 597 / 133 | 561 / 139 | |||
|
|
|
|
|
| |
Balance Detection |
|
|
|
|
| |
|
|
|
| |||
Vibration safety switch installed |
| N/A | STD | |||
|
|
|
| |||
Safety switch gap setting, in. (mm) |
| N/A | 0.006 (0.15) | |||
|
|
|
|
|
| |
Direct Steam Heating (Optional) |
|
|
|
|
| |
|
|
|
| |||
Steam inlet connection size, in. (mm) |
| 1/2 (13) | 1/2 (13) | |||
|
|
|
|
|
| |
Number of steam inlets |
|
| 1 |
| 1 | |
|
|
|
|
|
| |
Steam required to raise bath temperature, | LOW | 2.1 | (1.5) | 3.3 | (2.4) | |
10°F, lb. (10°C, kg) |
|
|
|
|
| |
MED | 2.3 | (1.7) | 3.7 | (2.6) | ||
| ||||||
|
|
|
|
|
| |
| HIGH | 2.7 | (1.9) | 4.1 | (2.9) | |
|
|
|
| |||
Average consumption per cycle, bhp (kg) |
| 1.4 (21.4) | 2.1 (33.4) | |||
|
|
|
|
|
| |
Electrical Heating (Optional) |
|
|
|
|
| |
|
|
|
| |||
Total electrical heating capacity, kW |
| 15.6 | 25.2 | |||
|
|
|
|
|
| |
Number of electrical heating elements |
|
| 6 |
| 6 | |
|
|
|
| |||
Electrical heating element size, kW |
| 2.6 | 4.2 | |||
|
|
|
|
|
| |
Time required to raise bath temperature, | LOW | 2.4 | (3.6) | 2.4 | (3.7) | |
10°F, min. (10°C, min.) |
|
|
|
|
| |
MED | 2.7 | (4.1) | 2.7 | (4.1) | ||
| ||||||
|
|
|
|
|
| |
| HIGH | 3.1 | (4.7) | 3.0 | (4.6) | |
|
|
|
|
|
|
Table 5
16 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F232156 |