Kenmore 110.8509# 1I31,J1 o*I, I1 31,/21o, Minimum installation spacing for cabinet installation

Page 7

Closet installation - Dryer only

t. 71:1t_1111

I I

24in,2

 

 

(7,6 cm)

I 1"I'_31,J_1' o'*I

+

(2.5cm) (80cm)

(0cm)

 

A

A. Side view - closet or confined area

B. Closet door with vents

*Side or bottom venting - additional spacing recommended Recessed or closet installation - Dryer on pedestal

Iit Iq ll,,,m.

 

OO

 

H

 

©

 

 

 

 

 

v

 

 

0"*_

27"

.<-- 0"*

I1"_ 31,/2"1o....

(0cm)

(6&6 cm)

(0 cm)

(2.5 ore)(80 cm)(0 ore)

 

A

 

B

A. Recessed area

B. Side view - closet or confined area

*Additional spacing recommended

**Side or bottom venting - additional spacing recommended

Minimum installation spacing for cabinet installation

The dimensions shown are for the minimum spacing allowed.

F; reCab_sn?tnithsttlolat iofn_hWitchadot rarmirni_uUlmdventilati on

rn) _ 7.8 crn)

(22.9 cra)

0"* 31W' 1"

0 ** 27

0 **

(0 crn) (80.0 crn) (2.5 cm) (0 crn) (68.6 crn) (0 crn)

Recommended installation spacing for recessed or closet installation, with stacked washer and dryer

The dimensions shown are for the recommended spacing.

48ir_.2 *

{310 crn 2)

3" (7.6cm)

o

3" (7.6

cm)

24 in._ *

1"(25cm)

(155cm_)

 

*Min. top and bottom air openings for closet door

6" (_=2 cm)

t

//

-_,

I

_ii i

78"

- _- (19:}cm)

5V_"** _ _- 1"*'1 ==}_

(14 cm)

(2.5cm)

8.8 cm) r

2.5cm

**External exhaust elbow requires additional space.

***Wall, door and floor molding may require additional spacing.

Mobile home - additional installation requirements

This dryer is suitable for mobile home installations.

The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).

Mobile home installations require:

Metal exhaust system hardware, which is available for purchase from your local Sears store or Sears Service Center.

Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.

*Additional spacing recommended

**Side or bottom venting - additional spacing recommended

Image 7
Contents 8576658 Sears Roebuck and Co., Hoffman Estates, IL 60179 U.S.AProtection Agreements Table of ContentsPedestal Option Warranty WarrantyElectrical Parts INSTRUCTiONS Dryer SafetyPedestal Color Part Height Number Parts suppliedParts needed MY-HOM EYou will need Dryer DimensionsInstallation clearances Custom undercounter installation Dryer only1I31,J1 o*I Minimum installation spacing for cabinet installationI1 31,/21o Electrical Connection To contact a qualified electrical installerIf connecting by direct wire It is your responsibilityPower Supply Cord Direct Wire Wire connection Power supply cord Style 2 Direct wire strain reliefWire connection Direct wire Page Page Flexible metal vent If using an existing vent systemIf this is a new vent system Vent material Rigid metal ventAlternate installations for close clearances Optional exhaust installationsBiscuit Hoods Special provisions for mobile home installationsVent system chart Number Type Box or Angled Turns VentReverse the hinge and hinge cover Door handle Hole plugs Reverse the door handleIf the dryer will not start, check the following To use an Auto Dry Cycle Dryer USETo make changes during an Auto Dry Cycle To pause the dryer at any time Cycle tips Dry most loads using the preset cycle settingsHow Auto Dry works To use a Manual CycleControl Locked Control Locked light glows when this option is enabledWrinkle Guard Express DRY TM Heavy DutyTimed DRY BULKY/BEDDINGType of Load Time When using Air DryEnd of Cycle Signal Air DryDryer Care To change the drum light To clean dryer drumMoving care For power supply cord-connected dryers From Inside the Dryer CabinetTroubleshooting Is the dryer being used for the first time? Has an air dry cycle been selected?Cycle time too short Lint on load Is the lint screen clogged?Page Solucion ProteccionSeguridad InstruccionesGarantia Completa DE UN Aiio Para LAS Piezas Garantia DE LA Opcion DE PedestalSu seguridad y la seguridad de los demis es muy importante Seguridad DE LA SecadoraGuarde Estas iNSTRUCCiONES Piezas para adquirir Piezas suministradasPieza Dimensiones de la secadora Espacio minimo para la instalacibn en un armario Instalaci6n en el cl6set S61o secadoraConexibn elctrica Usted es responsable dePonerse en contacto con un instalador electrico calificado Las instalaciones en casas rodantes necesitanSi emplea un cable de suministro elctrico Instrucciones Para LA CONEXt6N AtierraPeligro de Incendie Cable de suministro elctrico Cable directoEstilo Con Estilo 2 Protector de cables para cable directoConexibn de 4 hilos Cable de suministro elctrico Conexi6n de 4 hilos Cable directo Page Page Abrazaderas Si usa un sistema de ventilacibn existenteDucto de escape de metal rigido Ducto de escape de metal flexibleGrafito Bisque Seleccione su tipo de instalacibn de ventilacibnInstalaciones recomendadas de escape Instalaciones opcionales de escapeAngulares Metal Instalaciones alternas para espacios limitadosDeterminacibn de la via del ducto de escape Cuadro del sistema de ventilaci6nDesmontaje de la puerta Inversibn de la manija de la puerta Inversibn de la bisagra y de la tapa de la bisagraSi la secadora no funciona, revise Io siguiente Reinstalacibn de la puertaLavarJo USO DE LA SecadoraPara usar un ciclo de secado automatico Para detener su secadora en cualquier momento Para hacer cambios durante un ciclo de secado automaticoC6mo funciona el secado automatico Auto Dry Para usar un ciclo manualMojado Wet Luces indicadoras Indicator LightsSugerencias de secado Sugerencias de ciclosTouch UP NormalCasual TimedTipo de carga Tiempo Sehal de secado htmedo Damp Dry SignalProtector antiarrugas Wrin KLE Guard Secado con aire Air DryArticulos Sugeridos para Ajuste Tiempo Seffal de fin de ciclo End of Cycle SignalImportante Cuidado DE LA SecadoraPara secadoras con cableado directo Cuidado para las vacacionesCuidado para la mudanza Para secadoras conectadas al cable de suministro elctricoLas prendas estan enredadas o hechas un ovillo? Solucion DE ProblemasEsta el filtro de Pelusa obstruido Con pelusa? Es el suministro de energia el correcto?Se est usando la secadora por primera vez? Pelusa en la ropa Esta obstruido el filtro de pelusa?Page Wv,v.sears.com Your Home