Kenmore 110.8586# manual It is your responsibility, To contact a qualified electrical installer

Page 8

It is your responsibility

To contact a qualified electrical installer.

To be sure that the electrical connection is adequate and in conformance with the National Electrical Code, ANSl/NFPA 70-latest edition and all local codes and ordinances.

The National Electric Code requires a 4-wire supply connection for homes built after 1996, dryer circuits involved in remodeling after 1996, and all mobile home installations.

A copy of the above code standards can be obtained from: National Fire Protection Association, One Batterymarch Park, Quincy, MA 02269.

To supply the required 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.

Do not use an extension cord.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Electrical Connection

To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground wire is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the external ground conductor screw (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground wire is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.

If local codes do not permit the connection of a neutral ground wire to the neutral wire, see "Optional 3-wire connection" section.

A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations, (2) mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:

A UL listed 30-amp power supply cord, rated

120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.

A UL listed strain relief.

If your outlet looks like this:

4-wire receptacle (14-30R)

Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type

14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.

If your outlet looks like this:

3-wire receptacle (10-30R)

Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) and be:

Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.

10-gauge solid copper wire (do not use aluminum).

At least 5 ft (1.52 m) long.

GROUNDING INSTRUCTIONS

m For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for eiectric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

m For a permanently connected dryer:

This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer.

WARNING : Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it wilI not fit the outlet, have a proper outlet installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

Image 8
Contents Sears Roebuck and Co., Hoffman Estates, IL 60179 U.S.A 8576658Table of Contents Protection AgreementsElectrical Parts WarrantyPedestal Option Warranty Dryer Safety INSTRUCTiONSParts supplied Parts neededMY-HOM E Pedestal Color Part Height NumberDryer Dimensions Installation clearancesCustom undercounter installation Dryer only You will needI1 31,/21o Minimum installation spacing for cabinet installation1I31,J1 o*I To contact a qualified electrical installer If connecting by direct wireIt is your responsibility Electrical ConnectionPower Supply Cord Direct Wire Style 2 Direct wire strain relief Wire connection Power supply cordWire connection Direct wire Page Page If using an existing vent system If this is a new vent system Vent materialRigid metal vent Flexible metal ventBiscuit Optional exhaust installationsAlternate installations for close clearances Special provisions for mobile home installations Vent system chartNumber Type Box or Angled Turns Vent HoodsReverse the hinge and hinge cover Reverse the door handle Door handle Hole plugsIf the dryer will not start, check the following To make changes during an Auto Dry Cycle Dryer USETo use an Auto Dry Cycle Cycle tips Dry most loads using the preset cycle settings How Auto Dry worksTo use a Manual Cycle To pause the dryer at any timeWrinkle Guard Control Locked light glows when this option is enabledControl Locked Heavy Duty Timed DRYBULKY/BEDDING Express DRY TMWhen using Air Dry End of Cycle SignalAir Dry Type of Load TimeDryer Care To clean dryer drum Moving care For power supply cord-connected dryersFrom Inside the Dryer Cabinet To change the drum lightTroubleshooting Has an air dry cycle been selected? Cycle time too shortLint on load Is the lint screen clogged? Is the dryer being used for the first time?Page Proteccion SeguridadInstrucciones SolucionGarantia DE LA Opcion DE Pedestal Garantia Completa DE UN Aiio Para LAS PiezasGuarde Estas iNSTRUCCiONES Seguridad DE LA SecadoraSu seguridad y la seguridad de los demis es muy importante Pieza Piezas suministradasPiezas para adquirir Dimensiones de la secadora Instalaci6n en el cl6set S61o secadora Espacio minimo para la instalacibn en un armarioUsted es responsable de Ponerse en contacto con un instalador electrico calificadoLas instalaciones en casas rodantes necesitan Conexibn elctricaInstrucciones Para LA CONEXt6N Atierra Si emplea un cable de suministro elctricoEstilo Cable de suministro elctrico Cable directoPeligro de Incendie Conexibn de 4 hilos Cable de suministro elctrico Estilo 2 Protector de cables para cable directoCon Conexi6n de 4 hilos Cable directo Page Page Si usa un sistema de ventilacibn existente Ducto de escape de metal rigidoDucto de escape de metal flexible AbrazaderasSeleccione su tipo de instalacibn de ventilacibn Instalaciones recomendadas de escapeInstalaciones opcionales de escape Grafito BisqueInstalaciones alternas para espacios limitados Determinacibn de la via del ducto de escapeCuadro del sistema de ventilaci6n Angulares MetalDesmontaje de la puerta Inversibn de la bisagra y de la tapa de la bisagra Inversibn de la manija de la puertaReinstalacibn de la puerta Si la secadora no funciona, revise Io siguientePara usar un ciclo de secado automatico USO DE LA SecadoraLavarJo Para hacer cambios durante un ciclo de secado automatico C6mo funciona el secado automatico Auto DryPara usar un ciclo manual Para detener su secadora en cualquier momentoLuces indicadoras Indicator Lights Sugerencias de secadoSugerencias de ciclos Mojado WetNormal CasualTimed Touch UPSehal de secado htmedo Damp Dry Signal Protector antiarrugas Wrin KLE GuardSecado con aire Air Dry Tipo de carga TiempoSeffal de fin de ciclo End of Cycle Signal Articulos Sugeridos para Ajuste TiempoCuidado DE LA Secadora ImportanteCuidado para las vacaciones Cuidado para la mudanzaPara secadoras conectadas al cable de suministro elctrico Para secadoras con cableado directoSolucion DE Problemas Esta el filtro de Pelusa obstruido Con pelusa?Es el suministro de energia el correcto? Las prendas estan enredadas o hechas un ovillo?Pelusa en la ropa Esta obstruido el filtro de pelusa? Se est usando la secadora por primera vez?Page Your Home Wv,v.sears.com