Airstream PNEG-343 Control Power Switch, Outside Light, Drying Mode Switch, Load Auger Switch

Page 9

DRYER CONTROL PANEL

CONTROL POWER

SWITCH

The power to the Electronic Moni- toring Control System is turned on or off with this switch.

OUTSIDE LIGHT

The dryer service light is turned on or off here. It also may be set on auto, which turns the light on while the dryer is running and off if a shutdown occurs.

DRYING MODE SWITCH

This is used to select staged batch or continuous flow drying. The switch will light only after the Elec- tronic Monitoring Control System has been turned on, the safety cir- cuit is okay and the reset button on the control panel has been pressed.

LOAD AUGER SWITCH

This is used to select the opera- tion of the fill auger. In both the auto and manual position the load auger will operate if the dryer is low on grain and will automatically shut off when the dryer is full. In the auto position only, the dryer will shut down after a preset period of time set on the out of grain timer, or if grain flow is interrupted to the dryer. The switch will light when- ever the load auger is operating.

(Note: If the load auxiliary mo- tor overload relay is being utilized in the dryer control panel, this switch will also control the opera- tion of the auxiliary equipment).

FAN SWITCHES

Each fan is turned on or off with this switch. The on position oper- ates the fan continuously during staged batch and continuous flow modes. The auto position operates the fan in staged batch during the dry and cool cycle. The switch will light up whenever the airflow switch is sensing airflow and the dryer is full of grain.

HEATER SWITCHES

Each burner is turned on or off with this switch. The auto position op- erates the burner in staged batch during the dry cycle. The on posi- tion will operate the burner only when the fan is running. The switch will light up only when the flame sensor detects the flame.

UNLOAD SWITCH

The unload switch turns the meter- ing rolls and discharge auger on or off, and selects the operation of the metering rolls.

In the 2 speed position if the moisture control switch is on, and the drying mode switch is turned to cont. flow, the metering roll speed will alternate between the high speed metering roll potentiometer setting and the low speedmeteringrollpotentiometerset- ting depending on the control signal from the moisture control thermo- stat. The discharge auger will oper- ate continuously.

In the 1 speed position, if the mois-

ture control switch is on, and the dry ing mode switch is turned to cont. flow, the metering roll speed will op- erate at the high speed metering roll potentiometer setting or turn off de- pending on the control signal from the moisture control thermostat. The discharge auger will operate when ever the metering rolls are operating.

In both the 1 speed or the 2 speed position, if the moisture control switch is off, and the drying mode switch is turned to cont. flow, the metering roll speed can be manu- ally controlled by adjusting the high speed metering roll potenti- ometer. The discharge auger will operate continuously.

If the drying mode switch is turned to staged batch, the unload switch should be set to the 1 speed posi- tion. The discharge auger and metering rolls will only operate during the unload cycle of the staged batch operation, and the speed of the metering rolls is ad-

justed using the high speed me- tering roll potentiometer.

(Note: If the unload auxiliary motor overload relay is being uti- lized in the dryer control panel, this switch will also control the opera- tion of the auxiliary equipment.)

LOW SPEED METERING ROLL POTENTIOMETER

This is used to adjust the low speed of the metering roll when the 2 speed automatic moisture control feature of the dryer is in use.

9

Image 9
Contents Ryer Operation Page Table of Contents Series Dryer Operation and ServiceWarranty Safety Alert Symbol Safety FirstSafety Alert Decals Careful Operator Is the Best Insurance Against AN AccidentSafety Alert Decals Keep the Dryer Clean Do not Allow Fine Safety PrecautionsDryer Control Panel Moisture Control SwitchMoisture Control Thermostat Information regarding dryer operationDrying Mode Switch Control Power SwitchLoad Auger Switch FAN SwitchesDryer Power Stop Switch Dryer Power Start SwitchSetting the OUT Grain Timer Setting the DRY, Cool Batch and Unload TimersElectronic Monitoring Control System Turning on Electronic Monitoring Control SystemSetting the Load Unload Delays Dryer Safety CircuitUtilizing Bushel Counter Safety Circuit Shutdown Messages PRE Season Inspection Dryer PRE Start ChecksLoad Auger TWO Speed OperationONE Speed Operation Metering Roll OperationBurner Test Fire Burner SafetyStaged Batch Check Dryer ShutdownEmergency Turn the control power switch to on Continuous Flow and Continuous Batch Start UP ProcedureDryer Start UP Continuous Flow OperationSeries Continuous Flow Metering Roll Settings Dryer Start UP & OperationFull Heat Dry & Cool Continuous Flow Metering Roll SettingsStaged Batch Operation Matically shut down during the cooling and unloading cycles Staged Batch FAN & Heater Switch SettingsFull Heat Dry & Cool Series Batch Timer SettingsSeries Staged Batch Timer Settings Series Service Guide Service Seasonal Inspection and ServiceLube Procedures Insulation Class Consistency Type Grease Frame Type Suggested LubricantsFAN Propellor Removal and Installation Threaded Bushing HolesClearance Holes FAN Motor Removal and Installation Heater Parts Removal and Installation Main Controls Metering Roll ServicingHOW to Determine a Metering Roll Problem HOW to Clear a Jammed Metering RollService Tool Series Wiring Diagrams INPUT/OUTPUT Board Terminal Identification Series Wiring to Control BOX Series Control Wiring Series Safety Wiring Diagram Series Front Panel Internal Wiring Series Front Panel External Wiring Dryer FAN can Control Wiring Series 220 Volt Single Phase Control Wiring Series 220 Volt 3 Phase Power Wiring Series 440 Volt 3 Phase Power Wiring Problem Possible Cause Trouble Analysis ProcedureDisplay shows Burner 1, 2 or 3 Warning Flame May not be turning. The air switch may need adjustment Problem Possible Cause Trouble Analysis Procedure Press the enter button when desired setting is reached Quick Reference GuideChange the marquee on the LCD dis- play Page