Strip 5" (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5"

(12.7 cm). Cut 1¹⁄₂" (3.8 cm) from 3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends of wires into a hook shape.

1" .5cm) (2

5"

(12.7

cm)

 

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.

1.Remove center silver-colored terminal block screw.

2.Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.

A B

C

E

D

A. External ground conductor screw - Dotted line shows position of NEUTRAL ground wire before being moved to center silver-colored terminal block screw.

B. Center silver-colored terminal block screw C. Neutral wire (white or center wire)

D. ¾" (1.9 cm) UL listed strain relief E. Neutral ground wire

3.Connect ground wire (green or bare) of power supply cable to external ground conductor screw. Tighten screw.

A B

C

F

E

D

A.External ground conductor screw

B.Center silver-colored terminal block screw

C.Neutral wire (white or center wire)

D.¾" (1.9 cm) UL listed strain relief

E. Ground wire (green or bare) of power supply cable F. Neutral ground wire

4.Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.

5.Tighten strain relief screws.

6.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold- down screw.

7.You have completed your electrical connections. Now go to “Venting Requirements.”

11

Image 11
Contents W10150622A Sécheuse ÉlectriqueTable DES Matières Table of ContentsYour safety and the safety of others are very important Dryer SafetyLocation Requirements Installation InstructionsTools and Parts Electrical Requirements U.S.A. Only If your outlet looks like this If connecting by direct wireElectrical Requirements Canada Only Electrical Connection U.S.A. Only Power Supply Cord Direct WireStyle 1 Power supply cord strain relief Style 2 Direct wire strain relief Wire connection Direct Wire Wire connection Power Supply Cord12.7 BDE CG F Optional 3-wire connection If this is a new vent system Vent material If using an existing vent systemVenting Requirements Clamps Plan Vent SystemSpecial provisions for mobile home installations Install Vent SystemAlternate installations for close clearances Vent system chartLevel Dryer Install Leveling LegsConnect Vent Reverse the strike Remove the door assemblyReinstall the door Reverse Door SwingIf the dryer will not start, check the following Complete InstallationU.S.A CanadaStarting Your Dryer To use a Sensor Dry Cycle Press PowerDryer USE To restart the dryer Stopping, Pausing or RestartingDrying and Cycle Tips To stop or pause your dryer at any timeCycles Status LightsModifiers Changing Cycles, Modifiers Options End of Cycle SignalOptions To use the drying rack Changing the Preset Dryness Level SettingsDrying Rack Option Changing Modifiers and Options after pressing StartDryer Care Cleaning the Dryer LocationCleaning the Lint Screen Cleaning the Dryer InteriorDryer Operation TroubleshootingVacation and Moving Care Changing the Drum LightDryer displaying code message Dryer ResultsUnusual sounds Loads are wrinkled Cycle time too shortLint on load Stains on load or drumCanada Assistance or ServiceAccessories U.S.AONE Year Limited Warranty Maytag Corporation Major Appliance WarrantyVotre sécurité et celle des autres est très importante Sécurité DE LA SécheusePièces nécessaires Instructions D’INSTALLATIONOutillage et pièces Pièces fourniesDégagements de séparation à respecter Exigences d’emplacementDimensions de la sécheuse Il vous faudra’est à l’utilisateur qu’incombe la responsabilité de Linstallation dans une maison mobile exigeEn cas de nouveau système dévacuation Exigences concernant lévacuationEn cas dutilisation du système dévacuation existant Évacuation Planification du système d’évacuationBrides de serrage Tableau des systèmes dévacuation Autres installations où le dégagement est réduitDéterminer litinéraire dacheminement du conduit Réglage de laplomb de la sécheuse Installation du système d’évacuationInstallation des pieds de nivellement Raccordement du conduit d’évacuationInversion de la gâche Inversion du sens douverture de la porteDépose de la porte Réinstallation de la porte Si la sécheuse ne démarre pas, vérifier ce qui suit Achever linstallationMise en marche de la sécheuse Utilisation DE LA SécheusePour remettre la sécheuse en marche Arrêt, pause ou remise en marchePour mettre la sécheuse en pause ou larrêter à tout moment Témoins lumineux Conseils pour le séchage et les programmesProgrammes Modificateurs Changement des programmes après avoir appuyé sur Start Signal de fin de programmeSignal de fin de programme Damp Dry Chime sonnerie indiquant un séchage humideJouets rembourrés ou oreillers Option de grille de séchageUtilisation de la grille de séchage Séchage sur grille Réglage Temp Durée Chandails en laineNettoyage de l’intérieur de la sécheuse Nettoyage de lemplacement de la sécheuseEntretien DE LA Sécheuse Nettoyage du filtre à charpieChangement de l’ampoule d’éclairage Du tambour Retrait de la charpie accumuléeDéménagement Sons inhabituels DépannageFonctionnement de la sécheuse Absence de chaleurLe filtre à charpie est-il obstrué de charpie? La sécheuse est-elle installée dans un placard?Résultats de la sécheuse Temps de programme trop courtAu Canada Assistance OU ServiceAccessoires Garantie DES Gros Appareils Ménagers Maytag Corporation W10150622A SP PN W10150623A