Strip 5" (12.7 cm) of outer covering from end of cable, leaving bare ground wire at 5"

(12.7 cm). Cut 11/2" (3.8 cm) from 3 remaining wires. Strip insulation back 1" (2.5 cm). Shape ends of wires into a hook shape.

1" .5cm) (2

3.Connect ground wire (green or bare) of direct wire cable to external ground conductor screw. Tighten screw.

A

D

 

5"

(12.7

cm)

 

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw, as shown.

E

B

F

C

1.Remove center silver-colored terminal block screw.

2.Remove neutral ground wire from external ground conductor screw. Connect neutral ground wire and place the hooked end (hook facing right) of the neutral wire (white or center wire) of direct wire cable under the center screw of the terminal block. Squeeze hooked ends together. Tighten screw.

B

A

C

D

E

A. External ground conductor screw - Dotted line shows position of NEUTRAL ground wire before being moved to center silver-colored terminal block screw.

B. Center silver-colored terminal block screw C. Neutral ground wire

D. Neutral wire (white or center wire) E. ¾" (1.9 cm) UL listed strain relief

A. External ground conductor screw

B. Ground wire (green or bare) of power supply cable

C. ¾" (1.9 cm) UL listed strain relief

D. Center silver-colored terminal block screw

E. Neutral ground wire

F. Neutral wire (white or center wire)

4.Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.

5.Tighten strain relief screw.

6.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold- down screw.

7.You have completed your electrical connection. Now go to “Venting Requirements.”

13

Image 13
Contents W10057349A Sécheuse ÉlectriqueÍndice Table of ContentsYour safety and the safety of others are very important Dryer SafetyOptional Pedestal Installation InstructionsDryer Dimensions Installation clearancesLocation Requirements You will needCloset installation Dryer only Recommended installation spacing for cabinet installationMobile home installations require Mobile home Additional installation requirementsElectrical Requirements U.S.A. Only It is your responsibilityIf connecting by direct wire If using a power supply cordIf your outlet looks like this Electrical Requirements Canada Only Style 1 Power supply cord strain relief Power Supply Cord Direct Wire Electrical Connection U.S.A. Only Style 2 Direct wire strain relief Wire connection Direct wire Wire connection Power supply cord12.7 BDE CG F Page Venting Requirements If using an existing vent systemIf this is a new vent system Vent material Exhaust Optional exhaust installationsSpecial provisions for mobile home installations Alternate installations for close clearancesDetermine vent path Install Leveling Legs Install Vent SystemVent system chart Connect Vent Complete InstallationU.S.A CanadaStarting Your Dryer Dryer USETo use a Sensor Cycle How Sensor Cycles Work Air DryTo use a Timed Cycle Type of Load Time MinutesStopping Your Dryer Pausing or RestartingControl Lock Drying and Cycle TipsCycles Status IndicatorOptional Features Drying Rack Option Changing Cycles, Options and ModifiersCleaning the Lint Screen Cleaning the Dryer LocationEvery load cleaning As needed cleaningRemoving Accumulated Lint Cleaning the Dryer InteriorVacation and Moving Care Changing the Drum LightDryer Operation TroubleshootingCycle time too short Dryer ResultsLint on load For further assistance CanadaOur consultants provide assistance with This limited warranty does not cover Maytag Major Appliance WarrantyVotre sécurité et celle des autres est très importante Sécurité DE LA SécheusePièces fournies Instructions DinstallationPièces nécessaires Piédestal facultatif Exigences demplacementInstallation dans un placard Sécheuse seulement Dimensions de la sécheuseDégagements de séparation à respecter Linstallation dans une maison mobile exige Espacement recommandé pour linstallation dans un placardSpécifications électriques ’est à l’utilisateur qu’incombe la responsabilité deEn cas dutilisation du système dévacuation existant Exigences concernant lévacuationConduit métallique flexible Conduit métallique rigideCoudes Brides de serrageAutres installations où le dégagement est réduit Installations d’évacuation facultativesPlanification du système d’évacuation Tableau des systèmes dévacuation Déterminer litinéraire dacheminement du conduitMise à niveau de la sécheuse Installation des pieds de nivellementSi la sécheuse ne démarre pas, vérifier ce qui suit Utilisation dun programme de détection Utilisation DE LA SécheuseComment fonctionnent les programmes de détection Utilisation dun programme minutéArrêt de la sécheuse Verrouillage des commandesPause ou remise en marche Conseils pour les programmesProgrammes Témoins lumineuxCaractéristiques supplémentaires Changement des programmes, options et Modificateurs Cycle signal signal de programmeGrille de séchage RetoucheJouets rembourrés ou oreillers Séchage sur grille Réglage Temp Durée Chandails en laineChaussures de tennis ou de toile Entretien DE LA Sécheuse Nettoyage de lemplacement de La sécheuseNettoyage du filtre à charpie Nettoyage de l’intérieur de la sécheuseDéménagement Retrait de la charpie accumuléeChangement de l’ampoule d’éclairage Du tambour Fonctionnement de la sécheuse DépannageLa sécheuse ne fonctionne pas Absence de chaleur La sécheuse affiche un message codéRésultats de la sécheuse „ La sécheuse est-elle installée dans un placard?„ Le conduit dévacuation a-t-il la longueur appropriée? Temps de programme trop courtPour plus d’assistance Pour plus dassistanceNos consultants fournissent de lassistance pour Nos consultants vous renseigneront sur les sujets suivantsLa présente garantie limitée ne couvre pas Garantie DES Gros Appareils Ménagers MaytagW10057349A