Bosch Appliances installation manual Point Assignments, D9112 Program Record Sheet

Page 40

Figure 14: D9112 Program Record Sheet

Point Assignments

Six switches on each POPIT assign the module to a point number. POPIT switch settings are found in the Point Assignment section of the D9112 Program Sheet. See Figure 14.

D9112 Program Record Sheet

The first column on the program record sheet contains the switch settings for the POPITs. Switches are numbered 1 to 6, left to right. Set switches whose number appears in the setting to the ON position. Set switches with a dash (-) in the switch position in the setting to the OFF position. See Figure 14.

The second column contains the translation of the point number into the D8112 ZONEX format. See Point User Flag in the Panel Wide Parameters module of the D9112 Program Entry Guide (74-06145-000) for an explanation of this feature.

The third column contains the point number as it is displayed at command centers. The fourth column contains the point index. See the Point Index Parameters module in the D9112 Program Entry Guide (74-06145-000) for an explanation of the point index.

The fifth column of the record sheet shows the area the point is assigned to. The sixth column shows the Debounce Count for the point. See Debounce Count in the Point Assignments module in the D9112 Program Entry Guide (74-06145-000).

The seventh column shows the BFSK report code. It is the point number reported for this point when the panel is using the BFSK format. The eighth column contains the text displayed at command centers for the point. The text is transmitted to the receiver when the panel is using the Modem II format.

 

D9112 Operation & Installation Manual

 

74-06144-000-C 2/96

Page 40

© 1993-1996 Radionics

Image 40
Contents D I O N I C S FCC Notices Part74-06144-000-C 2/96 Table of Contents Programmer and Accessory Connections Installation Guide for UL and Fire ApplicationsCurrent Rating Chart for Standby Battery Calculation forD8128A OctoPOPIT Switch Settings Figures and TablesIntroduction PointsD1255 Alpha III Command Center KeyswitchAreas and Accounts CommunicatorEvent Memory Event LogEMI/Lightning Transient Protection ProgrammingOther Features D9112 Control/Communicator Assembly D9112 AssemblyOrdered Separately Literature PackListings and Approvals FireBurglary Factory Mutual FMInstallation Beginning the InstallationBefore You Begin Enclosure OptionsPremises Wiring Connecting Earth Ground TerminalInstalling the D9112 Assembly Locking the Reset Pin Lock the Reset Pin NowFinishing the Installation Charge the Battery as You FinishInstall and Wire Detection Devices Install Modules and RelaysInstall the Point Chart Label Connect the On-Board Points and Command CentersPower Up Programming the PanelTesting the System Power Supply Primary Power TerminalsPrimary AC Power Circuit Installing the TransformerSecondary Power Terminals Secondary DC PowerInstalling the Battery Battery SupervisionBattery Charging Circuit Battery Discharge/Recharge Schedule No AC PowerFloat Charge Discharge CycleLow Battery LED Red Charging Status and Low Battery LEDsCharging Status LED Yellow Available Power Power OutputsCircuit Protection Continuous Power Outputs Terminals Accessory Connector J2Continuous Current Draw Expansion Port J4Programmable Power Outputs Terminals Relay InstallationProgramming Optional Relays RequiredAvailable Power Verification/Reset RelayTerminals 6 TerminalTelephone Connections RegistrationNotification LocationPhone Cord Connection Phone LED RedOperation Monitor LED Green Dialing FormatRelay Installation Ground StartD128 Dual Phone Line Switcher Ground Start JumperDescription OperationInstalling the D128 Watchdog FeaturePrimary Phone Lines, Primary Phone Numbers AC Power LED D128 Status LEDsPrimary Fail LED Secondary Fail LEDDescription Terminals 11 to On-Board PointsPoint Sensor Loops Point Parameters Point Response TimePoint Zonex Buss Terminals 23 to Off-Board PointsD8125 Popex Module D8127 Popit Modules Installing the D8125 Popex Module Wiring the D8125 to the D9112Listings MountingD9112 D8125Zonex +UP to 63 Point PointsWiring POPITs to the Data Expansion Loop Data Expansion Loop Wire SpecificationsWiring Data Expansion Loops to Popex Modules Popit Sensor LoopsPoint Assignments D9112 Program Record SheetVertical Grid for Popex #1 Popit LabelsD8128A OctoPOPIT Module Installing the OctoPOPITListing Wiring OctoPOPITs to the D9112 D8128A OctoPOPITsLine Termination Point Assignment Switches Sensor Loop SwitchesOctoPOPIT Sensor Loops D9112 Point # Sensor LoopTesting Off-board Points Configuring the D8129 OctoRelay Off-board RelaysD8129 OctoRelay Relay OutputsD8129 Switch Settings Installation Wiring ConnectionsD811 Arm Status Relay Module Relay OutputD811 Module Wiring D1255 Command Centers Terminals 29 to D1255 Address SettingsArming Devices DescriptionD9112 Command Center Terminal Function Wire Color D1255 ConnectionsPower at Command Centers D9112Keyswitch Operation Maintained ContactMomentary Contact Silencing the BellProgrammer and Accessory Connections Programmer Connector J7Programmer Access Reports Accessory Connector J2Expansion Port J4 D9112 Quick Reference Terminal Description Terminal Name DescriptionInstallation Guide for UL and Fire Applications Introduction Optional Compatible EquipmentBurglary Applications Fire ApplicationsFire Applications Enclosures System Chart D129 Class aSystem Wiring Diagram, Issue a Total a = Total B = Total C 1 = Current Rating Chart for Standby Battery CalculationsCurrents shown in milliamperes 1 ampere=1000 milliamperes Standby Battery Requirements Central Station or Local Fire AlarmRemote Station or Auxiliary Fire Alarm Household Burglary and Commercial BurglaryCurrent Chart First Central Station or Local SystemsRemote Station or Auxiliary Systems Household Fire Ampere-Hour Calculation FormulaTroubleshooting Guide Self DiagnosticsCall for Service Trouble at Command Center Panel Broken Hardware, Software FailedServc AC Fail AC Power Failed Servc Batt LOW Battery Voltage LowServc Batt Msing Battery Missing, Shorted, or Reversed Servc Keypad Supervised Command Center MissingSymptom Diagnosis Remedy Phone Line TroubleCommunications Failure Problems Programming the Panel Zonex BUSProblems with Points See Problems with Data Expansion LoopSymptom Diagnosis Remedy Symptom Diagnosis Remedy Problems with the D8125 Popex Data Expansion Loops Metering the LoopsEMI on Long Wire Runs Checking Shielded CableProblems with Command Centers NCI #1, #40Watchdog Reset Reports Battery and Power ReportsRunaway Reports to the Receiver Overloaded Power Supply Service Walk Test Service Walk ? Command 5 9 Shows Firmware Revision Command 5 7 Toggles Default Idle TextPress Command 5 Specifications Compatible Accessories SDI BusTelephone Connections Environmental