Bosch Appliances D9112 installation manual System Wiring Diagram, Issue a

Page 65

74-06144-000-C 2/96

D122 DUAL

BATTERY HARNESS

-

+

-

+

 

 

D8004

 

 

TRANSFORMER

16 VAC

 

ENCLOSURE

 

 

 

40 VA

 

 

ARMING STATION

 

 

60 HZ

 

 

 

TRANSFORMER

 

 

PARALLEL

PRINTER

D9131 PARALLEL

PRINTER

D9112

AS REQUIRED

D8132

BATTERY

CHARGER

D126

BATTERY 12V 7Ah

D126

BATTERY 12V 7Ah

 

 

 

 

 

D1255

 

 

 

 

 

UP TO EIGHT

D1640

 

 

D9112

17-05823-000

SUPERVISED

 

 

 

Operation Monitor

P

P

LEDs Off When Normal

Digital Alarm Communicator Transmitter

Pulses When Normal

 

 

 

 

 

Flickers When Ringing GRN

P

S

YEL

Charging Status

 

Solid When Held In Reset

 

 

 

 

P

 

 

 

 

Reset Pin

 

RED Low Battery

 

P

 

 

 

 

Disable All Except Battery

 

 

 

Reference Manual #74-06144-000 figure #19 For Wiring Diagram

Charging And Local Programming

 

 

 

Reference Document #73-06143-000 for Compatible Smoke Detectors

 

 

 

1

 

 

32

 

 

2

 

 

31

 

 

 

 

 

INTERFACE

 

 

 

 

 

 

 

UP TO 63

 

 

 

 

 

 

D8126 U/T OR

 

 

 

 

 

 

D8127 U/T

 

 

 

 

 

 

POPITS

D8125 POPEX 1

 

 

 

 

 

IN

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Page

Operation &

65

Installation

D126

BATTERY 12V 7Ah

D126

BATTERY 12V 7Ah

LISTED

AUDIBLE SIGNALING DEVICES RATED AT 10.2 TO 13.8 VDC (DO NOT USE VIBRATING TYPE HORNS)

D192A

AUX PWR

ALARM TRIG

COM

SUPV IN

ALARM CKT

P +

- P

SS

J 3 P

S

D128

 

P

S

P

 

S

 

TO RJ31X FOR

PRIMARY

PHONE LINE

P

3

 

 

 

 

30

 

 

 

4

 

 

 

 

29

 

 

 

5

 

 

 

 

28

P S

 

 

6

 

 

 

 

27

P

S

 

 

 

 

 

 

 

 

7

 

 

 

 

26

P

S

 

8

 

 

 

 

25

 

P S

 

 

 

 

 

 

 

 

9

 

 

 

 

24

P

 

 

10

 

 

 

 

23

P

 

 

LINE SNIFFER SELECT

 

 

 

 

 

 

 

 

Loop Start

 

 

 

 

 

 

 

 

Ground Start

 

 

 

PROG

 

 

 

 

 

 

 

 

CONN

 

 

 

TELCO

GROUND

RED PHONE

 

 

 

 

 

 

CORD

START

LED

 

 

EXP

 

 

 

 

Requires

 

 

 

 

 

 

 

Relay

 

 

 

PORT

 

 

 

MODEL No.

#D136

ON WHEN

11

12

13 14 15 16 17 18 19 20 21 22

 

 

 

COMMUNICATING

 

 

 

D161

In J5

OFF WHEN IDLE

 

 

 

 

 

 

 

 

D105 FL

EOL DEVICE

(FOR TYPICAL BURGLAR ALARM APPLICATIONS)

 

GND AUX OUT

+

 

 

 

 

 

CONNECT UP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO EIGHT

 

 

 

 

 

 

 

 

 

 

 

 

OCTORELAYS

 

 

 

 

 

 

DATA AUX GND

 

OR D811 ARM STATUS RELAY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UP TO 63

 

 

 

 

 

 

 

D8129

 

 

 

 

 

 

 

 

D8126 U/T OR

 

 

 

 

 

 

OCTORELAY

 

D8127 U/T

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POPITS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN OUT AUX GND

-

 

 

 

 

 

 

 

 

 

 

 

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D8125 POPEX 2

 

 

 

 

 

 

 

CONNECT UP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO EIGHT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OCTORELAYS

 

 

 

 

 

 

 

 

AUX GND

DATA

Manual

© 1993-1996 Radionics

ECL DEVICE 15-03130-001

TO RJ31X FOR

SECONDARY

PHONE LINE

P= POWER LIMITED

S= SUPERVISED

1 10 3 4 2 or 5

D125

P - + - + P

SS

LOOP B

6 7 5 8 9

1

2

3D129

4

10 11 12 13

L

O

O

P

A

 

TYPICAL INITIATING DEVICES ARE

D105 FL EOL

DOOR CONTACTS NO/NC, FLOOR

MATS, MOTION SENSORS, GLASS

DEVICE

BREAK DETECTORS, ETC.

 

SUITABLE FOR VALVE TAMPER

AND OTHER TYPES OF

EXTINGUISHING SYSTEM

SUPERVISION.

D129 PROVIDES OPTIONAL WATERFLOW ALARM RETARD FEATURE. NOT SUITABLE FOR 2-WIRE SMOKE DETECTORS. NOTE: USE ZERO RETARD EXCEPT FOR WATERFLOW.

D8128A OCTORELAY

OR D811 ARM STATUS RELAY

System Wiring Diagram, Issue A

Image 65
Contents D I O N I C S Part FCC Notices74-06144-000-C 2/96 Table of Contents Installation Guide for UL and Fire Applications Programmer and Accessory ConnectionsCurrent Rating Chart for Standby Battery Calculation forFigures and Tables D8128A OctoPOPIT Switch SettingsPoints IntroductionKeyswitch D1255 Alpha III Command CenterAreas and Accounts CommunicatorEvent Log Event MemoryEMI/Lightning Transient Protection ProgrammingOther Features D9112 Assembly D9112 Control/Communicator AssemblyOrdered Separately Literature PackFire Listings and ApprovalsBurglary Factory Mutual FMBeginning the Installation InstallationBefore You Begin Enclosure OptionsInstalling the D9112 Assembly Connecting Earth Ground TerminalPremises Wiring Lock the Reset Pin Now Locking the Reset PinCharge the Battery as You Finish Finishing the InstallationInstall and Wire Detection Devices Install Modules and RelaysConnect the On-Board Points and Command Centers Install the Point Chart LabelPower Up Programming the PanelTesting the System Primary Power Terminals Power SupplyPrimary AC Power Circuit Installing the TransformerSecondary DC Power Secondary Power TerminalsInstalling the Battery Battery SupervisionBattery Discharge/Recharge Schedule No AC Power Battery Charging CircuitFloat Charge Discharge CycleCharging Status LED Yellow Charging Status and Low Battery LEDsLow Battery LED Red Circuit Protection Power OutputsAvailable Power Accessory Connector J2 Continuous Power Outputs TerminalsContinuous Current Draw Expansion Port J4Relay Installation Programmable Power Outputs TerminalsProgramming Optional Relays RequiredVerification/Reset Relay Available PowerTerminals 6 TerminalRegistration Telephone ConnectionsNotification LocationPhone LED Red Phone Cord ConnectionOperation Monitor LED Green Dialing FormatGround Start Relay InstallationGround Start Jumper D128 Dual Phone Line SwitcherDescription OperationPrimary Phone Lines, Primary Phone Numbers Watchdog FeatureInstalling the D128 D128 Status LEDs AC Power LEDPrimary Fail LED Secondary Fail LEDPoint Sensor Loops On-Board PointsDescription Terminals 11 to Point Response Time Point ParametersD8125 Popex Module D8127 Popit Modules Off-Board PointsPoint Zonex Buss Terminals 23 to Wiring the D8125 to the D9112 Installing the D8125 Popex ModuleListings MountingD8125 D9112Zonex +UP to 63 Point PointsData Expansion Loop Wire Specifications Wiring POPITs to the Data Expansion LoopPopit Sensor Loops Wiring Data Expansion Loops to Popex ModulesD9112 Program Record Sheet Point AssignmentsPopit Labels Vertical Grid for Popex #1Listing Installing the OctoPOPITD8128A OctoPOPIT Module D8128A OctoPOPITs Wiring OctoPOPITs to the D9112Line Termination OctoPOPIT Sensor Loops Sensor Loop SwitchesPoint Assignment Switches Sensor Loop D9112 Point #Testing Off-board Points Off-board Relays Configuring the D8129 OctoRelayD8129 OctoRelay Relay OutputsD8129 Switch Settings Wiring Connections InstallationRelay Output D811 Arm Status Relay ModuleD811 Module Wiring D1255 Address Settings D1255 Command Centers Terminals 29 toArming Devices DescriptionD1255 Connections D9112 Command Center Terminal Function Wire ColorD9112 Power at Command CentersMaintained Contact Keyswitch OperationMomentary Contact Silencing the BellProgrammer Connector J7 Programmer and Accessory ConnectionsExpansion Port J4 Accessory Connector J2Programmer Access Reports D9112 Terminal Name Description Quick Reference Terminal DescriptionInstallation Guide for UL and Fire Applications Optional Compatible Equipment IntroductionBurglary Applications Fire ApplicationsFire Applications Enclosures D129 Class a System ChartSystem Wiring Diagram, Issue a Currents shown in milliamperes 1 ampere=1000 milliamperes Current Rating Chart for Standby Battery CalculationsTotal a = Total B = Total C 1 = Central Station or Local Fire Alarm Standby Battery RequirementsRemote Station or Auxiliary Fire Alarm Household Burglary and Commercial BurglaryCentral Station or Local Systems Current Chart FirstHousehold Fire Ampere-Hour Calculation Formula Remote Station or Auxiliary SystemsSelf Diagnostics Troubleshooting GuideCall for Service Trouble at Command Center Panel Broken Hardware, Software FailedServc Batt LOW Battery Voltage Low Servc AC Fail AC Power FailedServc Batt Msing Battery Missing, Shorted, or Reversed Servc Keypad Supervised Command Center MissingPhone Line Trouble Symptom Diagnosis RemedyCommunications Failure Zonex BUS Problems Programming the PanelSee Problems with Data Expansion Loop Problems with PointsSymptom Diagnosis Remedy Symptom Diagnosis Remedy Metering the Loops Problems with the D8125 Popex Data Expansion LoopsChecking Shielded Cable EMI on Long Wire RunsNCI #1, #40 Problems with Command CentersRunaway Reports to the Receiver Battery and Power ReportsWatchdog Reset Reports Overloaded Power Supply Service Walk Test Service Walk ? Press Command 5 Command 5 7 Toggles Default Idle TextCommand 5 9 Shows Firmware Revision Specifications SDI Bus Compatible AccessoriesTelephone Connections Environmental