Sterling SGFE operating instructions Maintenance schedule

Page 28

Maintenance schedule

After the first 100

hours of operation: Change the oil on the rotary valve pumps Follow the manufacturer’s operating instructions

After 500 hours

of operation:Check oil level and condition of the oil in the gear box of the rotary lobe vacuum pumps

Follow the manufacturer’s operating instructions

After 20,000 hours

of operation:Remove old grease from anti-friction bearing

of side vane vacuum pump and apply fresh grease Follow the manufacturer’s operating instructions

F

The given maintenance intervals are average values.

Check whether in your individual case the maintenance in- tervals must be shortened.

SM4-618

Maintenance 4-4

Image 28
Contents Sterling Material Processing Parts and Service Department Technical service Edition 10/01Sgfe Table of contents Assembly instructions Technical data Spare parts list AccessoriesFunctional description Electrical manualSafety instructions GeneralFor your safety For your safety General For your safety Assembly For your safety Operation For the operating safety of the equipment Concerning these Operating Instructions General InformationConcerning these Operating Instructions Explanations and Definitions Concerning these Operating Instructions Start-up Control system Switching on the control system Key assignment Switching on the control systemSignal times flap B01 Setting the basic parametersChanges only after consultation with Sterling Service Line clearing B09 Setting the basic parameters Conveying time B05Emptying time B14 Setting the basic parameters Blower run on time B17 Error tolerance B22Starting the conveying procedure First conveying operationsViewing Alarm Messages Possible events Fault hopperSwitching off the unit Maintenance General Maintenance schedule Maintenance schedule Checking the direction of rotation of the vacuum generator Testing the conduit system If conditions points 3 + 4 are not fulfilled Adjusting the suction tubeIf the conditions points 3 + 4 are fulfilled Cleaning/replacing the filter cartridge RespServicing the accessories Assembly instructions Transport InstallationMaterial feed Suction pipe Pipework Vacuum generator Installing the accessories Rotary lobe vacuum pump GDKElectrical connection Functional description General Technical data Technical dataDimension sheet Sgfe Dimension sheet GDK 4 kW Dimension sheet GSVDimension sheet GDS Spare parts list Pos ID-No Designation OptionalAccessories Electrical manual