Sterling SGFE operating instructions Suction pipe

Page 36

Suction pipe

Please observe that the length of the hose should not exceed 3 m (9.84 ft.) Push the free pipe end into the flexible line to a depth of approx. 4-5 cm (1.67-1.97 in.) Connect both parts by means of a hose clamp.

5.4. Suction pipe

The suction pipe consists of an inner (A) and an outer pipe (B) which can be offset against each other.

Push the free pipe end into the flexible line to a depth of approx. 4-5 cm (1.67-1.97 in.)

Connect both parts by means of a hose clamp.

Please observe that the length of the hose should not exceed 3 m (9.84 ft.)

Please check that the outer pipe is not covered as it provides for unhindered ac- cess of ambient air.

Fcontainers, a suction box with 1-3 suction pipes is required.When conveying from silos, material hoppers and storage

B

A

 

MV

SM4-618

Assembly instructions 5-3

Image 36
Contents Sterling Material Processing Parts and Service Department Technical service Edition 10/01Sgfe Table of contents Assembly instructions Technical data Spare parts list AccessoriesFunctional description Electrical manualSafety instructions GeneralFor your safety For your safety General For your safety Assembly For your safety Operation For the operating safety of the equipment Concerning these Operating Instructions General InformationConcerning these Operating Instructions Explanations and Definitions Concerning these Operating Instructions Start-up Control system Switching on the control system Key assignment Switching on the control systemSetting the basic parameters Signal times flap B01Changes only after consultation with Sterling Service Setting the basic parameters Conveying time B05 Line clearing B09Emptying time B14 Setting the basic parameters Blower run on time B17 Error tolerance B22Starting the conveying procedure First conveying operationsViewing Alarm Messages Possible events Fault hopperSwitching off the unit Maintenance General Maintenance schedule Maintenance schedule Checking the direction of rotation of the vacuum generator Testing the conduit system Adjusting the suction tube If conditions points 3 + 4 are not fulfilledIf the conditions points 3 + 4 are fulfilled Cleaning/replacing the filter cartridge RespServicing the accessories Assembly instructions Installation TransportMaterial feed Suction pipe Pipework Vacuum generator Installing the accessories Rotary lobe vacuum pump GDKElectrical connection Functional description General Technical data Technical dataDimension sheet Sgfe Dimension sheet GDK 4 kW Dimension sheet GSVDimension sheet GDS Spare parts list Pos ID-No Designation OptionalAccessories Electrical manual