WARNING

THE OUTPUT VOLTAGE FROM AN INVERTER IS AS LETHAL AS

LANDLINE POWER.

It is therefore absolutely necessary for your safety to ensure that all Remote Area power installations meet and comply with the relevant provisions and requirements of wiring standards.

It is imperative that you ensure that only Electrical contractors are permitted to install any AC wiring in your system.

PRODUCT WARRANTY CONDITIONS

Selectronic Australia Pty Ltd warrants your SA41 inverter to be free from defects in materials and workmanship under normal use and service, for two (2) years.

This warranty is applicable from the date of original purchase. All parts will be replaced or repaired free of charge within this period. Travelling time for field service personnel is not covered under this warranty. The unit shall be returned at no cost to the owner, if no authorised field service personnel are available.

After you have completed our post-installation questionnaire, you will receive a lifetime warranty, applicable to the original purchaser only.

The provision of this warranty shall not apply if the unit has been subject to misuse, neglect, accidental damage, damage from external influences e.g. corrosion, used for a purpose it is not intended, acts of God or has not been installed in accordance with the manufacturers latest installation requirements. (Any installation updates will be mailed to your last known address.) Lifetime warranty is dependant on the supply of raw materials from suppliers, above and beyond Selectronic Australia’s legal obligation.

Freight charges to the point of purchase and the cost of any repairs resulting from damages occurring during this freighting will be borne by the owner.

Any alterations or repairs by unauthorised parties will void your warranty.

To ensure fast efficient handling of any warranty claims, please complete and return your reply paid warranty card within 30 days from date of purchase. If service is required, please return your inverter in its original carton with proof of purchase and a brief description of the fault, to your point of service or any of the following service centres:

Selectronic Australia

Burley TV Service

Reid Technology Ltd

RF Analysis

25 Holloway Drive

278 Edmondson Ave

3-5 Auburn Street

Harness Cask Road

Bayswater

Austral

Takapuna

 

Dorrigo

Victoria 3153

NSW 2171

North Shore City

NSW 2453

Australia

Australia

Auckland

NZ

Australia

Ph: 03 9762 4822

Ph: 02 606-0279

Ph: 9 489-8100

Ph: 066 57 8003

Fax: 03 9762 9646

 

Fax: 9 489-8585

Fax: 066 57 8002

29

Image 29
Contents Selectronic Australia Introduction Warranty CardInstallation Supply Connection of AC and DC WiringRED = Battery Positive + Black = Battery Negative Operation Status Standby Inverter OFF Inverter on Status ResetEnergy Management StatusWhere the Optional 200 AMP Current Shunt is Installed Minimum Charge On with OFF Set Control On with on On with Time Set Control SettingsController Outputs Duration LockoutBuzzer on / OFF More SettingsBuzzer Lockout SET DAYLockout Alarm Inputs AC Volts SettingAlarm Input Current Shunt Settings External ShuntCharge in Battery Battery CapacityMinimum Charge in Battery LOW Charge AlarmOverload Shutdown and Alarms Alarm 1 Active Fault FindingAlarm 2 Active Heatsink TOO HOTInverter Shuts Down with LOW Volts Battery Maintenance System MaintenanceSA41 Maintenance Demand Start Section SA41 Electrical SpecificationsHandy Hint Radio Frequency InterferenceTransformer Temperature Appendix I DiagnosticsHeatsink Temperature Demand Start CurrentAppendix II Flow Diagram for Displays and Settings Diagnostic Displays Switching Between READINGS, Minimum CHARGE, and DiagnosticsMinimum Charge Display Minimum charge DisplaysCO+LAH INV CO, LO A/H orFrom previous SA-SB-01 Interface KIT Appendix III SA Inverter OptionsGeneral SA-SB-01 Interface Connections Alarm Inputs ExamplesExt. Keypad no Set Parameters Installation of SA-KP-01 Optional KeypadAmps 0.0A OUT Battery Installation of SA-S200 Optional Current ShuntExt. Shunt no Set Parameters Zero DC Amps OFF Set ParametersProduct Warranty Conditions Mounting Template for SA-KP-01 Keypad