Toro owner manual System Maintenance, SA41 Maintenance, Battery Maintenance

Page 17

SYSTEM MAINTENANCE

To get the optimum performance from your SA41 power inverter, particularly under heavy appliance loads, it is essential that the battery bank and the DC wiring are all in good condition. The small amount of time spent on the suggested maintenance tasks that follow will maximise the reliability of your system.

SA41 MAINTENANCE

Periodic maintenance of the SA41 inverter involves little more than checking for unobstructed operation of the cooling fan, which is located at the rear of the inverter. Note that cooling air is drawn in through vents underneath the inverter.

Suggested inverter maintenance should include:

1.Check for unobstructed fan operation. Clear away any dust or foreign matter from the fan grill using a soft bristled brush. (Do not direct high pressure compressed air at the fan blades)

Note that the fan is designed to come on during heavy power demand.

2.Check between fins of the heatsinks and clean out any accumulated foreign objects, for example, insect nests.

3.Verify that the air flow beneath the chassis is not restricted.

4.Clean external surfaces of the SA41 using a soft, lint free cloth, with polish and wax. e.g. Mr. Sheen.

BATTERY MAINTENANCE

1.Every week, carry out a thorough visual inspection of all battery wiring, taking particular note of the condition of inter-connections between cells.

IMPORTANT:

When working on batteries of such high capacity, it is essential that you wear protective clothing, some form of eye protection and rubber-soled work boots. Please regard your batteries with a great deal of caution, and if in any doubt, entrust this work to your installer.

2.Check that the stainless steel inter-connecting bolts are tight and have minimal corrosion. If corrosion is evident, carefully follow the following procedure.

(a)Disconnect the system battery fuse before working on the battery bank.

(b)Unbolt the stainless steel bolts and nuts of any corroded connections and thoroughly clean the join with a wire brush or file, taking extreme care not to short circuit any battery cells with any tools.

(c)Re-assemble and smear a small amount of Vaseline or similar grease over the surface of the joint to slow down any future corrosion.

3.Every month: measure the specific gravity (SG) of each cell using your hydrometer, to ensure that all cells are performing correctly. Any serious imbalance should be reported to your system designer in case remedial action needs to be taken.

17

Image 17
Contents Selectronic Australia Introduction Warranty CardInstallation Supply Connection of AC and DC WiringRED = Battery Positive + Black = Battery Negative Operation Status Standby Inverter OFF Inverter on Status ResetEnergy Management StatusWhere the Optional 200 AMP Current Shunt is Installed Minimum Charge On with OFF Set Control On with on On with Time Set Control SettingsController Outputs Duration LockoutBuzzer on / OFF More SettingsBuzzer Lockout SET DAYLockout Alarm Inputs AC Volts SettingAlarm Input Current Shunt Settings External ShuntCharge in Battery Battery CapacityMinimum Charge in Battery LOW Charge AlarmOverload Shutdown and Alarms Alarm 1 Active Fault FindingAlarm 2 Active Heatsink TOO HOTInverter Shuts Down with LOW Volts Battery Maintenance System MaintenanceSA41 Maintenance Demand Start Section SA41 Electrical SpecificationsHandy Hint Radio Frequency InterferenceTransformer Temperature Appendix I DiagnosticsHeatsink Temperature Demand Start CurrentAppendix II Flow Diagram for Displays and Settings Diagnostic Displays Switching Between READINGS, Minimum CHARGE, and DiagnosticsMinimum Charge Display Minimum charge DisplaysCO+LAH INV CO, LO A/H orFrom previous SA-SB-01 Interface KIT Appendix III SA Inverter OptionsGeneral SA-SB-01 Interface Connections Alarm Inputs ExamplesExt. Keypad no Set Parameters Installation of SA-KP-01 Optional KeypadAmps 0.0A OUT Battery Installation of SA-S200 Optional Current ShuntExt. Shunt no Set Parameters Zero DC Amps OFF Set ParametersProduct Warranty Conditions Mounting Template for SA-KP-01 Keypad