Toro SA41 owner manual Minimum Charge

Page 7

NETT AMP HOURS TODAY

Net AH : 69 IN

- - - Today - - -

BATTERY CHARGE

Charge : 87%

- - - In Battery - - -

This reading gives a nett figure of Amp Hours since midnight last night. A nett AH reading of IN indicates more Amp Hours have gone into the battery than have been used. The opposite applies for a Net AH reading of OUT.

1 Amp Hour = 1 amp for 1 hour, or 2 amps for ½ hour, etc.

This reading shows the amount of charge present in you battery bank at any given time. i.e. 100% means a fully charged battery.

MINIMUM CHARGE

With the optional current shunt (SA-S200) installed, the minimum charge in your batteries today, this week or for a number of weeks or days can be logged (Minimum daily discharge). Minimum charge readings are accessed by pressing the UP and DOWN keys together for 1 second.

These vital readings give you the information you need to maximise your battery life. This is done by managing your loads to maximise this figure, e.g. using heavier loads later in the day or at other times when the battery charge is high.

MINIMUM CHARGE TODAY

MIN CHARGE : 76%

- - - In Batt Today - - -

The minimum charge in the battery since midnight last.

MINIMUM CHARGE THIS WEEK

MIN CHARGE : 76%

- - - In Batt This Wk - - -

The minimum charge in the battery since midnight last Saturday.

MINIMUM CHARGE WEEKLY LOG

Weeks ago : 1

Min Charge : 76%

This displays a log of the minimum weekly charge in the battery for up to 52 weeks. The logged weeks may be stepped through by pressing the UP or DOWN key. The weeks that have not logged AH as yet will display 255%.

MINIMUM CHARGE DAILY LOG

Days ago : 1

Min Charge : 76%

This displays a log of minimum daily charge in the battery for up to 30 days. The logged days may be stepped though by pressing the UP or DOWN key. The days that have not logged AH as yet will display 255%.

7

Image 7
Contents Selectronic Australia Installation Warranty CardIntroduction Supply Connection of AC and DC WiringRED = Battery Positive + Black = Battery Negative Status Status Standby Inverter OFF Inverter on Status ResetOperation Energy ManagementWhere the Optional 200 AMP Current Shunt is Installed Minimum Charge Controller Outputs SettingsOn with OFF Set Control On with on On with Time Set Control Duration LockoutSET DAY More SettingsBuzzer on / OFF Buzzer LockoutLockout Current Shunt Settings External Shunt AC Volts SettingAlarm Inputs Alarm InputLOW Charge Alarm Battery CapacityCharge in Battery Minimum Charge in BatteryOverload Shutdown and Alarms Heatsink TOO HOT Fault FindingAlarm 1 Active Alarm 2 ActiveInverter Shuts Down with LOW Volts SA41 Maintenance System MaintenanceBattery Maintenance Demand Start Section SA41 Electrical SpecificationsHandy Hint Radio Frequency InterferenceDemand Start Current Appendix I DiagnosticsTransformer Temperature Heatsink TemperatureAppendix II Flow Diagram for Displays and Settings Minimum charge Displays Switching Between READINGS, Minimum CHARGE, and DiagnosticsDiagnostic Displays Minimum Charge DisplayCO+LAH INV CO, LO A/H orFrom previous General Appendix III SA Inverter OptionsSA-SB-01 Interface KIT SA-SB-01 Interface Connections Alarm Inputs ExamplesExt. Keypad no Set Parameters Installation of SA-KP-01 Optional KeypadZero DC Amps OFF Set Parameters Installation of SA-S200 Optional Current ShuntAmps 0.0A OUT Battery Ext. Shunt no Set ParametersProduct Warranty Conditions Mounting Template for SA-KP-01 Keypad