APPENDIX I: DIAGNOSTICS

The "Diagnostics" is a special set of displays that give additional information about the SA41. These are normally only used when advanced troubleshooting is undertaken. The "Diagnostics" section displays the transformer and heatsink temperature, demand start current and software version information.

"Diagnostics" is accessed by holding both UP and DOWN buttons together twice, for at least 1 second each time, during the display of any "Readings" screen with the exception of "Status". The NEXT DISPLAY key takes you through the "Diagnostics" displays, eventually returning to the "Readings" display. See page 22 for more information.

TRANSFORMER TEMPERATURE

TX Temp : 75C

* * Diagnostics * *

This display is the operating temperature of the transformer inside the SA41 in degrees Celsius.

HEATSINK TEMPERATURE

HS1 Temp : 34C * * Diagnostics * *

This displays the operating temperature of the left heatsink.

HS2 Temp : 34C * * Diagnostics * *

This displays the operating temperature of the right heatsink.

DEMAND START CURRENT

D/S Current : 48

* * Diagnostics * *

SOFTWARE VERSION

SELECTRONIC C

SA41 1.00 1996

This gives a reading of the value read by the demand start sense circuit and can be useful during advanced demand start troubleshooting.

This displays the revision of the software running your SA41.

Please note that this software is Copyright to SELECTRONIC AUSTRALIA P/L and it is an offence to copy or duplicate any part of this program. This is the last screen in the "Diagnostics" and pressing the NEXT DISPLAY key once more will return you to the readings.

20

Image 20
Contents Selectronic Australia Introduction Warranty CardInstallation Connection of AC and DC Wiring SupplyRED = Battery Positive + Black = Battery Negative Status Standby Inverter OFF Inverter on Status Reset OperationEnergy Management StatusWhere the Optional 200 AMP Current Shunt is Installed Minimum Charge On with OFF Set Control On with on On with Time Set Control SettingsController Outputs Lockout DurationMore Settings Buzzer on / OFFBuzzer Lockout SET DAYLockout AC Volts Setting Alarm InputsAlarm Input Current Shunt Settings External ShuntBattery Capacity Charge in BatteryMinimum Charge in Battery LOW Charge AlarmOverload Shutdown and Alarms Fault Finding Alarm 1 ActiveAlarm 2 Active Heatsink TOO HOTInverter Shuts Down with LOW Volts Battery Maintenance System MaintenanceSA41 Maintenance SA41 Electrical Specifications Demand Start SectionRadio Frequency Interference Handy HintAppendix I Diagnostics Transformer TemperatureHeatsink Temperature Demand Start CurrentAppendix II Flow Diagram for Displays and Settings Switching Between READINGS, Minimum CHARGE, and Diagnostics Diagnostic DisplaysMinimum Charge Display Minimum charge DisplaysINV CO, LO A/H or CO+LAHFrom previous SA-SB-01 Interface KIT Appendix III SA Inverter OptionsGeneral Alarm Inputs Examples SA-SB-01 Interface ConnectionsInstallation of SA-KP-01 Optional Keypad Ext. Keypad no Set ParametersInstallation of SA-S200 Optional Current Shunt Amps 0.0A OUT BatteryExt. Shunt no Set Parameters Zero DC Amps OFF Set ParametersProduct Warranty Conditions Mounting Template for SA-KP-01 Keypad