Baldor MIN1853 manual General Specifications, Vac, Vdc, Protection & Indicators Description

Page 97

General Specifications

Description

 

 

Unit

LX1P1A07F9

 

LX1P1A03F9

 

LX1P2A03F9

 

 

 

 

 

 

 

 

 

Input Voltage Range

Nominal

VAC

 

115

 

230

 

Minimum

 

 

92

 

184

 

Maximum

 

 

132

 

265

 

 

 

 

 

 

 

 

Input Frequency

 

 

Hz

 

50/60 ± 5%

 

 

 

 

 

 

 

 

 

 

Nominal Output Bus

Nominal

VDC

 

160

 

320

(@ 115 / 230 input)

Minimum

 

 

88

 

176

 

Maximum

 

 

220

 

440

Adjustable in 0.1A increments

 

 

 

 

 

 

ARMS

0.1 – 7.9

 

0.1 – 3.0

 

0.1 – 3.9

Resolution

 

 

in (mm)

 

5.5 x 10–5(1.02 x 10–3)

 

Efficiency

 

 

%

 

85

 

 

 

 

 

 

 

 

 

Motor Inductance

 

 

mH

 

2 – 60

 

8 – 240

 

 

 

 

 

 

 

 

Switching Frequency

 

 

kHz

 

20

 

 

 

 

 

 

 

Encoder

 

 

Optically Isolated, differential line driver, 5VDC, 500 KHz

 

 

 

 

Max (2 MHz post quadrature)

 

 

 

 

 

 

 

Inputs

 

 

8 – Programmable + 2 Limit and 1 Home inputs.

(24VDC

 

 

 

 

maximum – optically isolated 3mA sink current at 0.7Volts)

 

 

 

 

 

 

Output Power

 

 

12VDC @ 250mA (Pull–ups)

 

 

 

 

 

5VDC @ 200mA (encoder)

 

 

 

 

 

Programmable Outputs

8 – Open collector (100mA maximum sink current).

 

 

 

 

 

 

Programming

 

 

Keypad or Serial communications

 

 

 

 

 

Operating Temperature

° F 〈° C)

32 to 100 (0 to 40); 122 (50) Maximum

 

 

 

 

 

 

 

Operating Altitude

 

 

ft (m)

 

8300 (2540) Maximum

 

 

 

 

 

 

 

 

Storage Temperature

 

 

° F 〈° C)

 

–13 to 158 (–25 to 70)

 

 

 

 

 

 

 

 

Humidity (non–condensing)

%

 

 

10–90

 

 

 

 

 

 

Shock

 

 

 

10G (according to DIN IEC 68–2–6/29)

 

 

 

 

 

Vibration

 

 

 

1G @ 10 – 150 Hz (according to DIN IEC 68–2–6/29)

 

 

 

 

 

 

 

Protection & Indicators

 

Description

 

 

 

 

 

 

 

 

LED Indications

 

 

Green – Normal operation; Red – Fault condition; Amber – FLASH

 

 

 

fault Protection

 

 

 

 

 

 

 

 

Short Circuit

 

 

Disable on phase–to–phase, or phase–to–ground detected

 

 

 

 

 

Undervoltage

 

 

Disable if supply drops below 90 VAC

 

 

 

 

 

 

 

 

 

Over Temperature

 

 

Disable if heatsink > 70 ° C

 

 

 

 

 

 

 

 

 

Interlock

 

 

Disable if interlock connection broken

 

 

 

 

 

Regen/Overvoltage

 

 

Disable if bus voltage exceeds 220 VAC on 115 VAC units, 440 VAC

 

 

 

on 230 VAC unit

 

 

 

 

 

 

 

 

 

 

 

 

 

8-2 Specifications & Product Data

MN1853

Image 97
Contents LinStep+ Single-Axis Microstepping Indexer/Driver Table of Contents POS ProgProg To PAD From Troubleshooting Iv Table of Contents MN1853 Section General Information Limited WarrantyCE Compliance Could result in injury or death Product Notice Intended useCould result in damage to property Connection before you first ensure that power has been Do not touch any circuit board, power device or electricalDo not apply AC power before you ensure that grounds are Voltages that are conducted to its power input terminals.Instead, we recommend using a four wire Wye Extend more than 0.2 5 into keypad assemblyPower is removed from the drive Driver should have specifications compatible to the driveOverview Section Product OverviewMotors Product Overview MN1853 Power Dissipation Section Receiving and InstallationMechanical Installation Receiving & InspectionRecommended System Grounding for UL Recommended System Grounding 1 phase for CESystem Grounding Ungrounded Distribution System Input Power ConditioningDelay a Wire Size and Protection DevicesEurope BaldorConnection Locations 115VAC, 1 Axis Tools Required Keypad Nullmodem ConnectionsRS-232 PC Connections 9 & 25 Pin RS-232 Cable Connections for UL InstallationsRules for Daisy Chain Operation Daisy Chain ConnectionsWhere are these resistors placed? What is a termination resistor?RS485 PC Connections How many resistors should my system have?13 RS485 4 Wire Multi-Drop for UL Installations Limits Connections Discrete I/O ConnectionsET± Encoder Color Code Encoder Signal PVS100 Danaher 9-Pin D+5VDC AY0165A00 Leadwire Connection 9 pin to flying leads Motor ConnectorInterlock Intlk Ground GND21 Opto Racks PNP Converter DB25 Pin to Screw Terminal ConverterPNP Power Off Checks Start-Up ProcedurePower On Checks Action Display CommentsOverview Section Keypad OperationF1, F2, F3 Main Menu Menu KeyJOG F2 MenusComma Decimal PointAlpha New Program Edit MenuEdit an existing program Save the programExample of Naming a Program Naming a programUse the =O keys for additional alpha characters Entering Characters with the Alpha Key In edit modeSubmenu Setup Parameter Description of Setup Parameter Edit, Setup SubmenuPress EDIT, POS F3 Press YES F1 or no F3 Pressing Help in Menus and Sub-Menus Pressing Help in the Main MenuPressing Help In the Program Edit function Sequentially Eeprom message disappearsCOPY, to PAD Submenu Keypad Operation MN1853 Procedure Format Definition Section SetupValue Range AR unloaded + 12.987 x log + log 155 Tm * JrValue High Fine-Tuning OffsetsValue OFF Value Range N/AApplication Notes Configuring Encoder Resolution ERi Configure Your Application Mechanics Value inch Char Keypad Display Input Character Description Configure the I/ONo additional interrupts will be seen By one-half Fault AMP FaultBrake Over CurrentConfigure the Output States Configure the Optional Lxopto 44/88Configure JOG Parameters Configure End of Travel Switch PolarityConfigure Home Parameters Configuring Home Edge HEi Configure Power-up Program Value Enabled Range Enabled, Disabled Configure Serial CommunicationsData Type Description of Display Data Type Configure Miscellaneous Setup ParametersPOS1 VEL1Password Type Description Gives access to these menus General Password RulesSetup MN1853 Section Keypad Programming Keypad Program Command ListValue Units ExamplesExample Value Units RangeAC2 DE.5 VE12 DA3 GO DA3 GO DA3 GO DC Distance to Change Examples of DC move profiles, AC = seconds, VE=ips Example Distance to ChangeAC.1 VE60 DI2 GO DI1 GO DI-4 GO LP2 DI3 GO EB Value Units Range N/AIF2,1 EN EB DI2 GO =26 =27 =28 =12 =13 =17 =18 =22 =23RUN Edit Copy DELExample 3-Screen Menu Program GH Start Home Value N/A Units N/A Range N/A Units Range N/A Value N/A Units N/A Range i=1-16IF10 Gtpart a EB =1-400, name = any legal program nameIFPARTS=25 GS20 EB Units RangeLppieces IV12,LENGTHDilength Value Units N/A Range N/A Syntax MC+ MC Move Continuous Move Continuous MS27,COUNT Gthome Powerup ONL,GTON EOTMain VE5 DA20 GO= starting output number Syntax RGr RG Registration Value N/A Units N/A SQRESULT=0 SQ27.96,SQRESULTST1 AC1 DE1 VE25 DA6 GO VE50 DA0 GO EN Value N/A Units secondsSyntax VEr VE Velocity Helpful Hints Programming your application Summary of Expressions, Operators and FunctionsProgramming Overview Variables Example of Hosted ModeProgram Variable NamesVariable Name Description of Built-in Variable Type Built-in VariablesUsing Built-in Variable Arowrel Parts Non-Volatile VariablesLpnumber Arithmetic Operands and Equations AO15=VOLTAGE + ErrorBoolean Operators Increment/Decrement Variables Logical OperatorsExpressions Other Programming Samples WTAI12MAX TempCreate a Message and Read an Input Variable Setting an Output=On on-the-flyReading an Analog Input Value Read a 4 Digit BCD number, 2 Digits at a timeGET 4 Bcds Digit BCD=4 Digit BCD+2TW1Operating Mode Indications, 1 Axis Section TroubleshootingAdditional Information General Additional Information Serial Communications Problems Troubleshooting MN1853 Identification Section Specifications & Product DataLinStep+ LX 1 P 1 A- 0xF9 Protection & Indicators Description General SpecificationsVAC VDCDimensions Specifications & Product Data MN1853 Section CE Guidelines Wiring of Shielded Screened CablesCE Declaration of Conformity EMC Conformity and CE MarkingGrounding Earth EMC Wiring TechniqueCable Screens Grounding EMC Installation InstructionsSimulated Encoder Output Cable Grounding Input Signal Cable GroundingEncoder Cable Grounding Programming Template Appendix aAppendix MN1853 MN1853 Appendix A-3 Remote Keypad Mounting Template Baldor Electric Company MN1853 01 C&J Baldor Electric CompanyLinStep+ Single-Axis Microstepping Indexer/Driver