Graco 3A1214B important safety instructions Electrical Cable Connections

Page 17

5. Install air hose to quick connect fitting on air tank.

ti16914a

Electrical Cable Connections

1.Connect gun arm cable to the junction box. Fasten cable to cable clamp for strain relief (S) on the con- nection.

ti16596a

S

Setup

2.Connect control cable to the junction box. Fasten cable to cable clamp for strain relief (S) on the con- nection.

ti16595a S

3.Route the control cable to the cab of the vehicle without pinching the cable. Connect the cable to the control box. Route cable through the cable clamp for strain relief on the connection.

ti16601a

3A1214B

17

Image 17
Contents List of Models see Important Safety InstructionsComplete Assemblies ModelsFire and Explosion Hazard Equipment Misuse Hazard General Information Introduction and General InformationIntroduction Component Identification Component Function Charge Battery SetupFilter Orientation Single Hitch Mounting Bracket 24G626 Installation OptionGun Arm Bracket Mount Narrow Orientation RoadPak Mounting Bracket 24G627 Installation Option21 in. 25 Cm 63 cm Wide Orientation Gun Arm Installation 24G628, 24G629 Slide Beam Installation 24G630705 Hose Routing to Pumps and Tanks Hose Connection Hose RoutingElectrical Cable Connections Install and Align Front Mechanical Guidance System Optional Install Front Pointer InstructionsInstall and Align Video Guidance System Optional Install Winch Kit OptionalOperation Pressure Relief ProcedureRPS 2900 Pump Fluid Pressure Relief Bead System Pressure ReliefInitial Settings Set Up Slide Beam and Gun ArmLoad Reflecting Materials Prepare System to PaintSafe Range cold Select/Prime Pumps Start EngineTurn on Bead System Begin to SprayPrime Guns Flushing the System Perform Pressure Relief Procedure, seeOperation RoadLazer in Storage Position Securing Gun Arm for TransportationTechnical Data Graco Information Graco Standard Warranty