Graco 3A1214B Operation, Pressure Relief Procedure, RPS 2900 Pump Fluid Pressure Relief

Page 19

Operation

Operation

Pressure Relief Procedure

INJECTION HAZARD

The system pressure must be manually relieved to pre- vent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:

are instructed to relieve the pressure

stop spraying

check or service any of the system equipment

install or clean the spray tip

FIRE AND EXPLOSION HAZARD

When Flushing system, always connect grounding cord.

RPS 2900 Pump Fluid Pressure Relief

1. Set hydraulic valve to OFF position.

4.Relieve hose pressure through guns. Use Program- mable Skipline Controller to trigger each gun for at least 3 seconds each.

NOTE: Always relieve pressure with the guns--not with the filter drain valves.

5.Close paint gun ball valves.

ti15953a

6.Open all drain valves, one at a time.

7.Close valves immediately to prevent paint from dry- ing in system.

NOTE: If you suspect that the spray gun or hose is com- pletely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the hose end coupling, and relieve pressure gradually. Then loosen it completely. Then clear the valve or hose.

Bead System Pressure Relief

1.Relieve air pressure in bead tank by turning bead system valve to OFF position.

 

ti15838a

 

2.

Run engine at half throttle.

 

3.

Place empty pail under paint guns to catch drain-

 

 

age.

ti16550a

3A1214B

19

Image 19
Contents List of Models see Important Safety InstructionsComplete Assemblies ModelsFire and Explosion Hazard Equipment Misuse Hazard Introduction Introduction and General InformationGeneral Information Component Identification Component Function Charge Battery SetupGun Arm Bracket Mount Single Hitch Mounting Bracket 24G626 Installation OptionFilter Orientation Narrow Orientation RoadPak Mounting Bracket 24G627 Installation Option21 in. 25 Cm 63 cm Wide Orientation Gun Arm Installation 24G628, 24G629 Slide Beam Installation 24G630705 Hose Routing to Pumps and Tanks Hose Connection Hose RoutingElectrical Cable Connections Install Winch Kit Optional Install Front Pointer InstructionsInstall and Align Front Mechanical Guidance System Optional Install and Align Video Guidance System OptionalBead System Pressure Relief Pressure Relief ProcedureOperation RPS 2900 Pump Fluid Pressure ReliefPrepare System to Paint Set Up Slide Beam and Gun ArmInitial Settings Load Reflecting MaterialsSafe Range cold Select/Prime Pumps Start EnginePrime Guns Begin to SprayTurn on Bead System Flushing the System Perform Pressure Relief Procedure, seeOperation RoadLazer in Storage Position Securing Gun Arm for TransportationTechnical Data Graco Information Graco Standard Warranty