Graco 3A1214B important safety instructions Fire and Explosion Hazard

Page 3

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

+

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

Use equipment only in well ventilated area.

Do not fill fuel tank while engine is running or hot; shut off engine and let it cool. Fuel is flammable and can ignite or explode if spilled on hot surface.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

Ground all equipment in the work area. See Grounding instructions.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

SKIN INJECTION HAZARD

High-pressure fluid from dispensing device, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate SURGICAL TREATMENT.

Keep clear of fluid outlet and leaks.

Use guns, hoses and other components with pressure ratings equal to or higher than the pump rating.

Follow the Pressure Relief Procedure before servicing or cleaning.

Do not point dispensing device at anyone or at any part of the body.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Tighten all fluid connections before operating the equipment.

Check hoses and couplings daily. Replace worn or damaged parts immediately.

MOVING PARTS HAZARD

Moving parts can pinch, cut or amputate fingers and other body parts.

Keep clear of moving parts.

Do not operate equipment with protective guards or covers removed.

Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure and disconnect all power sources.

3A1214B

3

Image 3
Contents List of Models see Important Safety InstructionsComplete Assemblies ModelsFire and Explosion Hazard Equipment Misuse Hazard Introduction and General Information IntroductionGeneral Information Component Identification Component Function Charge Battery SetupSingle Hitch Mounting Bracket 24G626 Installation Option Gun Arm Bracket MountFilter Orientation Narrow Orientation RoadPak Mounting Bracket 24G627 Installation Option21 in. 25 Cm 63 cm Wide Orientation Gun Arm Installation 24G628, 24G629 Slide Beam Installation 24G630705 Hose Routing to Pumps and Tanks Hose Connection Hose RoutingElectrical Cable Connections Install Winch Kit Optional Install Front Pointer InstructionsInstall and Align Front Mechanical Guidance System Optional Install and Align Video Guidance System OptionalBead System Pressure Relief Pressure Relief ProcedureOperation RPS 2900 Pump Fluid Pressure ReliefPrepare System to Paint Set Up Slide Beam and Gun ArmInitial Settings Load Reflecting MaterialsSafe Range cold Select/Prime Pumps Start EngineBegin to Spray Prime GunsTurn on Bead System Flushing the System Perform Pressure Relief Procedure, seeOperation RoadLazer in Storage Position Securing Gun Arm for TransportationTechnical Data Graco Information Graco Standard Warranty