KitchenAid KBSS271T installation instructions Gas Supply Requirements, Gas Connection Requirements

Page 8

Gas Supply Requirements

WARNING

Explosion Hazard

Use a new CSA International approved “outdoor” gas supply line.

Securely tighten all gas connections.

If connected to LP, have a qualified person make sure gas pressure does not exceed 11” (28 cm) water column.

Examples of a qualified person include:

licensed heating personnel,

authorized gas company personnel, and authorized service personnel.

Failure to do so can result in death, explosion, or fire.

Observe all governing codes and ordinances.

IMPORTANT: The installation of this grill must conform with local codes or, in the absence of local codes, with either the National Fuel Gas Code, ANSI Z223.1/NPFA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code, B149.2.

IMPORTANT: Grill must be connected to a regulated gas supply.

Refer to the model/serial rating plate for information on the type of gas that can be used. If this information does not agree with the type of gas available, check with your local gas supplier.

Gas Conversion:

No attempt shall be made to convert the grill from the gas specified on the model/serial rating plate for use with a different gas type without consulting the serving gas supplier. The conversion kits specified by the manufacturer must be used.

Gas Pressure Regulator

The gas pressure regulator supplied with this grill must be used. The inlet (supply) pressure to the regulator should be as follows for proper operation:

LP Gas:

Set pressure: 11" (27.9 cm) WCP

Inlet (supply) pressure: 11" to 14" (27.9 cm to 35.5 cm) WCP

Natural Gas:

Set pressure: 4" (10.2 cm) WCP

Inlet (supply) pressure: 7" to 14" (17.8 cm to 35.5 cm) WCP maximum.

Contact local gas supplier if you are not sure about the inlet (supply) pressure.

Burner Requirements for High Altitude

Input ratings shown on the model//serial rating plate are for elevations up to 2,000 ft (609.6 m).

For elevations above 2,000 ft (609.6 m), ratings are reduced at a rate of 4% for each 1,000 ft (304.8 m) above sea level. Orifice conversion is required for elevations above 2,000 ft (609.6 m). See “Assistance or Service” section to order High Altitude Conversion Kit.

Gas Supply Line Pressure Testing

Testing above ½ psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge):

The grill and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than ½ psig (3.5 kPa).

Testing below ½ psi (3.5 kPa) or 14" (35.5 cm) WCP (gauge) or lower:

The grill must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.5 kPa).

Gas Connection Requirements

Natural Gas

Built-in grill models are equipped for use with Natural gas. They are design-certified by CSA International for LP (propane) gases with appropriate conversion.

Built-in models are set for Natural gas use and have a pressure regulator with ½" female pipe threads.

A

 

 

B

D

C

 

A. Grill gas pipe

B. New CSA International approved “outdoor” flexible gas supply line

C. Rear of grill

D. To Natural gas supply

The supply line shall be equipped with an approved shutoff valve. This valve should be located in the same area as the grill and should be in a location that allows ease of opening and closing.

8

Image 8
Contents Outdoor Grills W10138384Table of Contents Table DES MatièresOutdoor Grill Safety Your safety and the safety of others are very importantImportant Safety Instructions Location Requirements Installation RequirementsToolsand Parts Built-In Outdoor Grill Enclosure Product DimensionsCabinet CutoutDimensions Recommended Ground Method Electrical RequirementsBuilt-in Outdoor Grill Enclosure Ventilation for LP Gas Gas Supply Requirements Gas Connection RequirementsInstallation Instructions LP Gas Conversion Using a Local LP Gas SupplyLP Gas Conversion Using a 20 lb LP Gas Fuel Tank Unpack GrillNatural Gas Use Make Gas ConnectionPlug in Grill To Install the 20 lb LP Gas Fuel Tank Conversion to LPGasCheck and Adjustthe Burners Burner Flame CharacteristicsLow Flame Adjustment To AdjustUsing YourOutdoor Grill Outdoor Grill USEControl Panel Prepare the Gas SupplyUsingYourInfrared SearBurner Turn the Gas Supply OnLighting the Grill and Infrared Sear Burner Manually Lighting Main Grill and Infrared Sear BurnersLighting the Rotisserie Burner UsingYourRotisserieTo Use Trussing Poultry for the Rotisserie RotisserieCooking TipsManually Lighting the Rotisserie Burner Using YourSmokerBox Tips for Outdoor GrillingHood Lights To Refill the Smoker Box During UseGrillingChart Cooking MethodsTotal minutes Pork ChickenFish and Seafood TurkeyGeneralCleaning Outdoor Grill CareChanging theLight Bulb Stainless SteelGrill Grates Warming ShelfExterior InteriorTroubleshooting Drip TrayKnobs and Flange Area around Knobs Control Panel GraphicsAssistance or Service AccessoriesTheU.S.A CanadaKitchenaid Outdoor Product Warranty ONE Year Limited WarrantyItems Kitchenaid will not PAY for Disclaimer of Implied Warranties Limitation of RemediesSécurité DU Gril Dextérieur Votre sécurité et celle des autres est très importanteConservez CES Instructions Outillageetpièces Exigences DinstallationExigences demplacement Enceinte du grildextérieurencastré Dimensionsdu produitDimensionsduplacard Méthode recommandée de mise à la terre Spécifications électriquesSpécifications delalimentation en gaz Exigences concernantleraccordement au gazÉlimination des matériaux demballage à lintérieur du gril Instructions ’INSTALLATIONDéballage du gril Raccordementau gaz Alimentation au gaz naturelConversionpourlalimentation Installation de la bouteille de propane de 20 lbBranchement dugril Processus de réglage Contrôle et réglagedes brûleursCaractéristiques des flammes sur les brûleurs Réglage pour le débit thermique minimum Tableau de commandeUtilisation DU Gril Dextérieur Utilisation du grildextérieur Ouvrir larrivée de gazAllumage du brûleur du gril et du brûleur à infrarouge Préparation de la source de gazUtilisation dubrûleur à infrarouge Utilisation du tournebrocheUtilisation Allumage du brûleur du tournebrocheTroussage de la volaille pour utilisation du tournebroche Conseils de cuisson à l’aide du tournebrocheAllumage manuel du brûleur du tournebroche Utilisation du fumoir Lampes sous le capotPour remplir le fumoir lors de la cuisson Tableau Dutilisation DU TournebrocheMéthodesdecuisson Tableau decuissonau grilMinutes au DU BrûleurTotal Bœuf PouletLégumes frais Total Poisson et fruits de merDinde Nettoyagegénéral Entretien DU Gril DextérieurChangement delampoule déclairage Intérieur Brûleurs EN Forme DE UBrûleurs À Infrarouge Plateau DégouttementAssistance OU Service DépannageAccessoires Garantie DES Produits Pour Usage Extérieur KitchenaidW10138384