Tanita WB-110MA, WB-100MA RS-232C Communication Specifications Troubleshooting, Possible Problems

Page 7

WB-100MA-取説/04.01.27 04.1.28 9:12 AM ページ12

4. RS-232C Communication Specifications

5.Troubleshooting

GB

■Specifications

Communication standard

EIA RS-232C

 

 

Communication method

Asynchronous method

 

 

Signal speed

2,400 baud

 

 

Data bit length

7 bit

 

 

Parity

EVEN

 

 

Stop bit

1 bit

 

 

■Names and connection methods for signal lines

Terminal no.

Signal name

 

 

1

 

2

TXD

3

RXD

4

 

5

GND

6

 

7

 

8

 

9

 

 

 

WPossible Problems

 

 

GB

If problems occur, please refer to the following instructions. If the problem persists contact your nearest Tanita sales or

repair center.

 

 

 

 

 

 

 

 

Problem

Solution

 

 

 

 

The unit does not turn on when the

•When Using with the AC Adapter

 

key is pressed.

Ensure that the AC Adapter cable is properly connected with the Display Unit. Ensure

 

 

that the AC Adapter is correctly inserted in the mains DC jack.

 

 

•Using dry cell batteries

 

 

The batteries may have run out. Confirm that the equipment is working by using the

 

m• An RS-232C connector (D sub 9 pin female) is attached to the side of the display box.

When connecting the display box with a personal computer, etc., please use an RS-232C straight cable.

Use the RS232C cable ahorter than 3m long.

■Weighing Mode

When receiving 4 bytes of data as indicated in 1-1 while using the scale in weighing mode, weight data will be output in 14 bytes, as indicated in 1-2.

1-1

Reception data

 

 

 

 

 

 

 

 

 

Details of Weighing Mode Transmission Data

 

1

2

3

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Byte nos. 1-2

Header

2 bytes fixed

SD: Unstable S_: Stable

 

 

 

D

R

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SI: Overload, etc.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-2

Transmission data

 

 

 

 

 

 

 

 

 

Byte nos. 3-4

Separator

2 bytes fixed

2 spaces

 

 

 

 

 

 

 

 

 

 

Byte nos. 5-10

Weight data

6 bytes fixed

Right-aligned

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4 5 6 7

8

9

10

11

12

13 14

 

 

Byte nos. 11-12

Measurement units

2 bytes fixed

Kg:kg

 

 

 

S

D

 

 

 

 

7

5

.

0

k

g

CR

LF

 

 

Byte nos. 13-14

Terminator

2 bytes fixed

CR+LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

■BMI Mode

While the scale is used in BMI mode, the output data will vary depending on the form of the received data.

aWhen receiving 4 bytes of data, as indicated in 1-1, the scale will calculate your BMI using the currently input height figure, and 26 bytes

of data will be output, as indicated in 2-1 or 2-2, depending on the measurement unit.

bWhen receiving 11 bytes of data, including measurement units and height figures, in the form indicated in 1-2 or 1-3, the scale will calculate your BMI using these figures, and 26 bytes of data will be output, as indicated in 2-1 or 2-2, depending on the measurement unit.

 

 

 

AC Adapter or new batteries.

 

 

Measurement is not correct.

•Please confirm that all the adjustable feet are resting on a level surface.

 

 

Measurement does not become stable.

•Measurement may be impossible in the case of excessive vibration. Use the equipment

Display turns on and off.

in another place.

 

 

 

 

 

 

is displayed.

•It is possible that the maximum weight capacity has been exceeded. Please stop

 

 

 

 

measuring.

 

 

 

 

 

 

 

 

 

is displayed.

•Do not stand on or put objects on the Platform before starting measurement. Start

 

 

 

 

measurement after confirming there is nothing on the Platform.

 

 

 

1-1 Reception data

1 2 3 4

DR CR LF

1-2 Reception data (height data when using kg)

1

2

3

4

5

6

7

8

9

10

11

D

H

k

g

 

 

1

8

0

CR

LF

 

 

 

 

 

 

 

 

 

 

 

*Please input 90-99cm height data as 090-099.

2-1 Transmission data (kg/cm)

Details of BMI mode transmission data

Byte nos. 1-2

Header

2 bytes fixed

SD: Unstable S_: Stable

 

 

 

SI: Overload, etc.

Byte nos. 3-4

Separator

2 bytes fixed

2 spaces

Byte nos. 5-10

Weight data

6 bytes fixed

Right-aligned

Byte nos. 11-12

Measurement units

2 bytes fixed

Kg:kg

Byte nos. 13

Separator

1 byte fixed

1 comma

Byte nos. 14-18

Height data

5 bytes fixed

Right-aligned

Byte nos. 19

Separator

1 byte fixed

1 comma

Byte nos. 20-24

BMI data

5 bytes fixed

Right-aligned

Byte nos. 25-26

Terminator

2 bytes fixed

CR+LF

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

S

D

 

 

 

 

7

5

.

0

k

g

,

 

 

1

8

0

,

 

2

3

.

1

CR

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

13

Image 7
Contents WB-100MA-取説/04.01.27 04.1.28 912 AM ページ1 Electronic ScaleTable of Contents Value Range Safety NotesTemperature Range for Use 0C / +35C Relative Humidity ApplicationsAdjustable Feet Symbols and their Meanings Product Assembly and ComponentsAdjustable Feet Battery Compartment Display Box AccessoriesWhen using dry cell batteries Level Adjustment Prepare Power SourceInstallation of the Equipment Remote Display Version When using the AC AdapterGuidelines based on NIH/WHO BMI Operating InstructionsPossible Problems RS-232C Communication Specifications TroubleshootingModell Remote Display Säulengestützte Version SpecificationsWB-100MA-取説/04.01.27 04.1.28 912 AM ページ14 RS-232C Kommunikationsspezifikationen Signalleitungen und VerbindungsmethodenInhaltsverzeichnis Modell Remote DisplayAnwendungen WarnsymboleSicherheitshinweise Einstellbare Füße Symbole und ihre BedeutungProduktaufbau und Komponenten BedienungsfeldVerwendung eines AC-Adapters Vorbereitungen vor GebrauchHöheneinstellung Vorbereiten der Stromquelle Aufbau des Geräts Modell Remote DisplayAbschalten der Eigengewichtsfunktion BetriebsanleitungenNormales Wiegen Bestimmen des Eigengewichts BMI-BerechnungRS-232C Kommunikationsspezifikationen Mögliche ProblemeFehlersuche Version Avec Téléaffichage Version à colonne montée SpezifikationenWB-100MA-取説/04.01.27 04.1.28 912 AM ページ28 Suppression de la fonction de pesée avec tare38 Liste et signification des symboles utilisésTable des matières Version Avec TéléaffichageRemarques sur la sécurité Symboles d’avertissementAssemblage du produit et composants Lors de lutilisation de ladaptateur CA Installation de lappareil Version Avec TéléaffichageAvant lutilisation Réglage du niveau BranchementBasé sur les directives NIH/WHO BMI IMC FonctionnementProblèmes possibles Mode de peséeMode BMI Mode IMC Caractéristiques pour commutation RS-232C DépannageTipo Con Display Separato Versione con montaggio a colonna CaractéristiquesWB-100MA-取説/04.01.27 04.1.28 912 AM ページ42 Caratteristiche tecniche Copertina posteriore IndiceTipo Con Display Separato Nomi e metodi di connessione per le linee di segnale54Range valore ApplicazioniSimboli di attenzione Range temperatura per l’uso 0C / +35C Umidità relativaPannello di controllo Montaggio prodotto e componentiSimboli e significati relativi Quando si utilizzano batterie Installazione dell’apparecchio Tipo Con Display SeparatoPreparazione per l’uso Quando si usa l’adattatore CACalcolo dell’Indice di Massa Corporea IMC Cancellazione della funzione peso della taraIstruzioni per il funzionamento Procedura di pesatura standardProblemi possibili Dettagli comunicazione RS-232C Risoluzione di problemiVersión de Indicación Remota Versión montada en la columna Caratteristiche tecnicheWB-100MA-取説/04.01.27 04.1.28 912 AM ページ56 WB-100MA-取説/04.01.27 04.1.28 912 AM ページ58 Cancelación de la función de pesado de taraÍndice Especificaciones del sistema de comunicación RS-232C68Humedad relativa FuncionesMedidas de seguridad Margen de temperatura funcional 0C / 35CMontaje de la báscula y componentes Cuando vaya a utilizar el adaptador de CA Preparación para el uso de la básculaNivelación Preparación de la fuente de alimentación Instalación de la báscula Versión de Indicación RemotaPesado BMI Cancelación de la función de pesado de taraInstrucciones de funcionamiento Procedimientos de pesado estándarEspecificaciones del sistema de comunicación RS-232C Posibles problemasIdentificación y solución de fallos WB-100MA-取説/04.01.27 04.1.28 912 AM ページ70 WB-100MA-取説/04.01.27 04.1.28 912 AM ページ72 Especificaciones