Percent Oxygen Analyzer

Introduction

 

 

 

Set Alarm 2

Sets the concentration at which alarm 2

 

activates upon dropping below the

 

threshold (LO alarm).

Set HI Range Set the high analysis range for the instrument (up to 0-100%).

Set LO Range Set the low analysis range for the instrument (down to 0-1%).

Span

Span calibrate the analyzer.

Data Entry Keys: Two pushbutton membrane switches are used to manually change measurement parameters of the instrument as they are displayed on the LED meter readout:

Up Arrow

Increment values of parameters upwards

 

 

as they are displayed on the LED readout.

Down Arrow

Increment values of parameters

 

 

downwards as they are displayed on the

 

 

LED readout.

Digital LED Readout: The digital display is a LED device that produces large, bright, 7-segment numbers that are legible in any lighting environment. It has two functions:

Meter Readout As the meter readout, it displays the oxygen concentration currently being measured.

Measurement Parameters Readout The parameter readout displays user-defined alarm setpoints, ranges, span calibration point when they are being checked or changed, and probe temperature on demand.

1.4Rear Panel Description

The rear panel contains the electrical input and output connectors. The connectors are described briefly here and in detail in the Installation chapter of this manual.

Teledyne Analytical Instruments

13

Image 13
Contents Teledyne Analytical Instruments Model 9060LCopyright 2005 Teledyne Instruments/ Analytical Instruments Model 9060LPercent Oxygen Analyzer Specific Model InformationSafety Messages Percent Oxygen Analyzer Table of Contents Operation MaintenanceAppendix Index Teledyne Analytical InstrumentsFront Panel List of FiguresList of Tables Combustible GAS Usage Introduction Main Features of the AnalyzerOverview Percent Oxygen Analyzer IntroductionIntroduction Model 9060L Front Panel DescriptionSpan Rear Panel DescriptionRear Panel Introduction Operational TheoryOxygen Probe, Sensor, and Heater Percent Oxygen Analyzer Operational TheoryModel 9060L Oxygen Probe Operational Theory Model 9060LProbe Options Probe ConfigurationInternal Structure of the Zirconia Sensor and Probe Zirconia SensorHeater Sensor Impedance Applications Not at Atmospheric PressureElectronics GeneralSignal Processing Block Diagram Signal ProcessingOperational Theory Model 9060L Control Unit Installation Installation9060L Oxygen Probe Installation Percent Oxygen Analyzer InstallationInstallation Model 9060L Electrical Connections Primary Input PowerAnalog Outputs Alarm RelaysAlarm #2 4Model 9060L Heated Probe Cable Connection Oxygen Probe ConnectionsConnections to Probe Installation ChecklistInstallation Model 9060L Teledyne Analytical Instruments Percent Oxygen Analyzer Operation OperationSetting the Analysis Ranges Using the Function and Data Entry ButtonsOperation Model 9060L Set Alarm 1 HI alarm Setting the Alarm SetpointsHI Range LO RangeSensor Fail Alarm Set Alarm 2 LO alarmSelecting a Fixed Range or Autoranging Span Calibration Oxygen CalibrationOperation Model 9060L Supplementary Information Probe TemperatureAir Calibration Low Temperature Error MessagesOpen Thermocouple Percent Oxygen Analyzer Operation Operation Model 9060L Teledyne Analytical Instruments Percent Oxygen Analyzer Maintenance MaintenanceReplacing the Fuse Maintenance Model 9060L Appendix SpecificationsAppendix Model 9060L Probe SpecificationsEmail asktai@teledyne.com Spare Parts ListAnalytical Instruments Probe or Sensor EMF Tables Reference DrawingZirconia Oxygen Sensor Output mV Percent Oxygen Analyzer Appendix Model 9060L Teledyne Analytical Instruments Index Index Model 9060L Percent Oxygen Analyzer