Teledyne 9060L, Percent Oxygen Analyzer Introduction, Overview, Main Features of the Analyzer

Page 11

Percent Oxygen Analyzer

Introduction

 

 

 

Introduction

1.1 Overview

The Teledyne Instruments/ Analytical Instruments (TI/AI) Model 9060L is a microprocessor-based percent oxygen analyzer for real-time measurement of the percent of oxygen in inert gases, or in a wide variety of gas mixtures. It features simple operation, fast response, and a compact, rugged construction. Typical applications of the Model 9060L are monitoring kilns, boilers, and flue gas at temperature from ambient up to 1400°C (2550°F).

1.2 Main Features of the Analyzer

The main features of the analyzer include:

High resolution, accurate readings of oxygen content from 0-1 % through 0-100 % O2. Large, bright, light-emitting-diode meter readout.

Simple pushbutton controls.

State of the art zirconia sensor.

Longer life probes with greater resistance to thermal shock and mechanical damage during installation and start-up.

Fast response and recovery time.

Microprocessor based electronics: 8-bit CMOS microprocessor with on-board RAM and 16 KB ROM.

Two user selectable ranges (from 0-1% through 0-100%) allow best match to user’s process and equipment.

Air-calibration range for convenient spanning at 20.9 %.

Operator can select autoranging, which allows the analyzer to automatically select the proper preset range for a given measurement, or lock the analyzer onto a single range.

Teledyne Analytical Instruments

11

Image 11
Contents Teledyne Analytical Instruments Model 9060LCopyright 2005 Teledyne Instruments/ Analytical Instruments Model 9060LPercent Oxygen Analyzer Specific Model InformationSafety Messages Percent Oxygen Analyzer Table of Contents Index Teledyne Analytical Instruments MaintenanceOperation AppendixFront Panel List of FiguresList of Tables Combustible GAS Usage Percent Oxygen Analyzer Introduction Main Features of the AnalyzerIntroduction OverviewIntroduction Model 9060L Front Panel DescriptionSpan Rear Panel DescriptionRear Panel Percent Oxygen Analyzer Operational Theory Operational TheoryIntroduction Oxygen Probe, Sensor, and HeaterModel 9060L Oxygen Probe Operational Theory Model 9060LProbe Options Probe ConfigurationInternal Structure of the Zirconia Sensor and Probe Zirconia SensorHeater General Applications Not at Atmospheric PressureSensor Impedance ElectronicsSignal Processing Block Diagram Signal ProcessingOperational Theory Model 9060L Percent Oxygen Analyzer Installation InstallationControl Unit Installation 9060L Oxygen Probe InstallationInstallation Model 9060L Electrical Connections Primary Input PowerAnalog Outputs Alarm RelaysAlarm #2 4Model 9060L Heated Probe Cable Connection Oxygen Probe ConnectionsConnections to Probe Installation ChecklistInstallation Model 9060L Teledyne Analytical Instruments Percent Oxygen Analyzer Operation OperationOperation Model 9060L Using the Function and Data Entry ButtonsSetting the Analysis Ranges LO Range Setting the Alarm SetpointsSet Alarm 1 HI alarm HI RangeSelecting a Fixed Range or Autoranging Set Alarm 2 LO alarmSensor Fail Alarm Span Calibration Oxygen CalibrationOperation Model 9060L Air Calibration Probe TemperatureSupplementary Information Open Thermocouple Error MessagesLow Temperature Percent Oxygen Analyzer Operation Operation Model 9060L Teledyne Analytical Instruments Replacing the Fuse MaintenancePercent Oxygen Analyzer Maintenance Maintenance Model 9060L Appendix SpecificationsAppendix Model 9060L Probe SpecificationsAnalytical Instruments Spare Parts ListEmail asktai@teledyne.com Zirconia Oxygen Sensor Output mV Reference DrawingProbe or Sensor EMF Tables Percent Oxygen Analyzer Appendix Model 9060L Teledyne Analytical Instruments Index Index Model 9060L Percent Oxygen Analyzer