Teledyne Percent Oxygen Analyzer, 9060L operating instructions Table of Contents

Page 6

Model 9060L

Table of Contents

List of Figures

viii

List of Tables

ix

Introduction

11

1.1

Overview

11

1.2

Main Features of the Analyzer

11

1.3

Front Panel Description

12

1.4

Rear Panel Description

13

Operational Theory

15

2.1

Introduction

15

2.2

Oxygen Probe, Sensor, and Heater

15

2.2.1 Probe Configuration

17

2.2.2 The Zirconia Sensor

18

2.2.3 Heater

19

2.3

Applications Not at Atmospheric Pressure

20

2.4

Sensor Impedance

20

2.5

Electronics

20

2.5.1 General

20

2.5.2 Signal Processing

21

Installation

23

3.1

Unpacking the Analyzer

23

3.2

Control Unit Installation

23

3.3

9060L Oxygen Probe Installation

23

3.4

Electrical Connections

25

3.4.1 Primary Input Power

25

3.4.2 Analog Outputs

26

3.4.3 Alarm Relays

26

Teledyne Analytical Instruments

vi

Image 6
Contents Model 9060L Teledyne Analytical InstrumentsModel 9060L Copyright 2005 Teledyne Instruments/ Analytical InstrumentsSpecific Model Information Percent Oxygen AnalyzerSafety Messages Percent Oxygen Analyzer Table of Contents Appendix MaintenanceOperation Index Teledyne Analytical InstrumentsList of Figures Front PanelList of Tables Combustible GAS Usage Overview Main Features of the AnalyzerIntroduction Percent Oxygen Analyzer IntroductionFront Panel Description Introduction Model 9060LRear Panel Description SpanRear Panel Oxygen Probe, Sensor, and Heater Operational TheoryIntroduction Percent Oxygen Analyzer Operational TheoryOperational Theory Model 9060L Model 9060L Oxygen ProbeProbe Configuration Probe OptionsZirconia Sensor Internal Structure of the Zirconia Sensor and ProbeHeater Electronics Applications Not at Atmospheric PressureSensor Impedance GeneralSignal Processing Signal Processing Block DiagramOperational Theory Model 9060L 9060L Oxygen Probe Installation InstallationControl Unit Installation Percent Oxygen Analyzer InstallationInstallation Model 9060L Primary Input Power Electrical ConnectionsAlarm Relays Analog OutputsAlarm #2 Oxygen Probe Connections 4Model 9060L Heated Probe Cable ConnectionInstallation Checklist Connections to ProbeInstallation Model 9060L Teledyne Analytical Instruments Operation Percent Oxygen Analyzer OperationUsing the Function and Data Entry Buttons Setting the Analysis RangesOperation Model 9060L HI Range Setting the Alarm SetpointsSet Alarm 1 HI alarm LO RangeSet Alarm 2 LO alarm Sensor Fail AlarmSelecting a Fixed Range or Autoranging Oxygen Calibration Span CalibrationOperation Model 9060L Probe Temperature Supplementary InformationAir Calibration Error Messages Low TemperatureOpen Thermocouple Percent Oxygen Analyzer Operation Operation Model 9060L Teledyne Analytical Instruments Maintenance Percent Oxygen Analyzer MaintenanceReplacing the Fuse Maintenance Model 9060L Specifications AppendixProbe Specifications Appendix Model 9060LSpare Parts List Email asktai@teledyne.comAnalytical Instruments Reference Drawing Probe or Sensor EMF TablesZirconia Oxygen Sensor Output mV Percent Oxygen Analyzer Appendix Model 9060L Teledyne Analytical Instruments Index Index Model 9060L Percent Oxygen Analyzer