Teledyne Percent Oxygen Analyzer, 9060L operating instructions Oxygen Probe Connections

Page 28

Installation

Model 9060L

 

 

 

3.4.1 Oxygen Probe Connections

The receptacle for the probe cable is located in the lower left-hand corner of the rear panel. The 6-pin polarized connector is keyed to fit only one way into the receptacle. Do not force it in. The other end of the cable connects to the probe assembly. See Figure 3-5. Connect the probe lead as shown in Figure 3-4 . The heater connector is on the right-hand corner of the rear panel. Six foot long cables are provided for the remote probe and the heater. Their Teledyne Analytical Instruments part numbers are listed on the spare parts list located in the appendix.

Figure 3-4:Model 9060L Heated Probe Cable Connection

Teledyne Analytical Instruments

28

Image 28
Contents Model 9060L Teledyne Analytical InstrumentsModel 9060L Copyright 2005 Teledyne Instruments/ Analytical InstrumentsSpecific Model Information Percent Oxygen AnalyzerSafety Messages Percent Oxygen Analyzer Table of Contents Maintenance OperationAppendix Index Teledyne Analytical InstrumentsList of Figures Front PanelList of Tables Combustible GAS Usage Main Features of the Analyzer IntroductionOverview Percent Oxygen Analyzer IntroductionFront Panel Description Introduction Model 9060LRear Panel Description SpanRear Panel Operational Theory IntroductionOxygen Probe, Sensor, and Heater Percent Oxygen Analyzer Operational TheoryOperational Theory Model 9060L Model 9060L Oxygen ProbeProbe Configuration Probe OptionsZirconia Sensor Internal Structure of the Zirconia Sensor and ProbeHeater Applications Not at Atmospheric Pressure Sensor ImpedanceElectronics GeneralSignal Processing Signal Processing Block DiagramOperational Theory Model 9060L Installation Control Unit Installation9060L Oxygen Probe Installation Percent Oxygen Analyzer InstallationInstallation Model 9060L Primary Input Power Electrical ConnectionsAlarm Relays Analog OutputsAlarm #2 Oxygen Probe Connections 4Model 9060L Heated Probe Cable ConnectionInstallation Checklist Connections to ProbeInstallation Model 9060L Teledyne Analytical Instruments Operation Percent Oxygen Analyzer OperationSetting the Analysis Ranges Using the Function and Data Entry ButtonsOperation Model 9060L Setting the Alarm Setpoints Set Alarm 1 HI alarmHI Range LO RangeSensor Fail Alarm Set Alarm 2 LO alarmSelecting a Fixed Range or Autoranging Oxygen Calibration Span CalibrationOperation Model 9060L Supplementary Information Probe TemperatureAir Calibration Low Temperature Error MessagesOpen Thermocouple Percent Oxygen Analyzer Operation Operation Model 9060L Teledyne Analytical Instruments Percent Oxygen Analyzer Maintenance MaintenanceReplacing the Fuse Maintenance Model 9060L Specifications AppendixProbe Specifications Appendix Model 9060LEmail asktai@teledyne.com Spare Parts ListAnalytical Instruments Probe or Sensor EMF Tables Reference DrawingZirconia Oxygen Sensor Output mV Percent Oxygen Analyzer Appendix Model 9060L Teledyne Analytical Instruments Index Index Model 9060L Percent Oxygen Analyzer