Teledyne Percent Oxygen Analyzer, 9060L operating instructions Rear Panel

Page 14

Introduction

Model 9060L

 

 

 

Figure 1-2 Rear Panel

Power Connection 110 VAC at 50/60 Hz. The connector housing includes the fuse holder and the power switch. (220VAC is optional via setting an internal switch).

Fuse Holder: Replacing the fuse is described in Chapter 5, Maintenance. I/O Power Switch: Turns the instrument power ON (1) or OFF (0).

Analog Outputs 0–10 VDC concentration output.

0–10 VDC range ID (or optional overrange) output.

4–20 mA DC concentration output, negative ground.

Alarm Connections Alarm 1 (HI alarm), Alarm 2 (LO alarm), and Probe Failure Alarm connections.

Sensor Connector For connecting the probe’s Oxygen sensor.

Heater Connector For connecting the probe’s heater

Teledyne Analytical Instruments

14

Image 14
Contents Model 9060L Teledyne Analytical InstrumentsModel 9060L Copyright 2005 Teledyne Instruments/ Analytical InstrumentsSpecific Model Information Percent Oxygen AnalyzerSafety Messages Percent Oxygen Analyzer Table of Contents Appendix MaintenanceOperation Index Teledyne Analytical InstrumentsList of Figures Front PanelList of Tables Combustible GAS Usage Overview Main Features of the AnalyzerIntroduction Percent Oxygen Analyzer IntroductionFront Panel Description Introduction Model 9060LRear Panel Description SpanRear Panel Oxygen Probe, Sensor, and Heater Operational TheoryIntroduction Percent Oxygen Analyzer Operational TheoryOperational Theory Model 9060L Model 9060L Oxygen ProbeProbe Configuration Probe OptionsZirconia Sensor Internal Structure of the Zirconia Sensor and ProbeHeater Electronics Applications Not at Atmospheric PressureSensor Impedance GeneralSignal Processing Signal Processing Block DiagramOperational Theory Model 9060L 9060L Oxygen Probe Installation InstallationControl Unit Installation Percent Oxygen Analyzer InstallationInstallation Model 9060L Primary Input Power Electrical ConnectionsAlarm Relays Analog OutputsAlarm #2 Oxygen Probe Connections 4Model 9060L Heated Probe Cable ConnectionInstallation Checklist Connections to ProbeInstallation Model 9060L Teledyne Analytical Instruments Operation Percent Oxygen Analyzer OperationOperation Model 9060L Using the Function and Data Entry ButtonsSetting the Analysis Ranges HI Range Setting the Alarm SetpointsSet Alarm 1 HI alarm LO RangeSelecting a Fixed Range or Autoranging Set Alarm 2 LO alarmSensor Fail Alarm Oxygen Calibration Span CalibrationOperation Model 9060L Air Calibration Probe TemperatureSupplementary Information Open Thermocouple Error MessagesLow Temperature Percent Oxygen Analyzer Operation Operation Model 9060L Teledyne Analytical Instruments Replacing the Fuse MaintenancePercent Oxygen Analyzer Maintenance Maintenance Model 9060L Specifications AppendixProbe Specifications Appendix Model 9060LAnalytical Instruments Spare Parts ListEmail asktai@teledyne.com Zirconia Oxygen Sensor Output mV Reference DrawingProbe or Sensor EMF Tables Percent Oxygen Analyzer Appendix Model 9060L Teledyne Analytical Instruments Index Index Model 9060L Percent Oxygen Analyzer