3.3Rear Panel Connections

Figure 3-3 shows the Model BDS 3960 rear panel. There are ports for gas inlet and outlet, power, communication, and analog concentration output.

Figure 3-3: Rear Panel of the Model BDS 3960

3.3.1Gas Connections

The unit is manufactured with 1/4 inch VCR fittings with the exception of instrument air fitting. All of the gas connections are located on the rear of the analyzer. For all VCR fittings, insert a gasket (TAI PN G284) between the fittings and tighten the female and male nuts until fingertight; then by holding the male nut with a wrench, tighten the female nut with a second wrench an additional 1/6 turn.

SAMPLE IN: The gas of interest connections are made at the SAMPLE

IN andconnections. For zero calibration, the sample gas is rerouted through an oxygen scrubber to supply oxygen-free zero cal gas. A VCR fitting is provided for the inlet connection.

The inlet gas pressure should be regulated to pressures between 5 to 50 psig so that the internal regulator can be adjusted to maintain a flow between 0.5 to 1.0 SLPM. If pressure is too low, the flow will drop below 0.5 SLPM which is below the threshold to which the sensor is sensitive (see Section 2.2.2). If pressure is too high, it will force gas into the electrolyte and cause damage to the sensor. The internal pressure regulator is helpful if the sample pressure varies.

Teledyne Analytical Instruments

32

Image 32
Contents Oxygen Analyzer Teledyne Analytical InstrumentsBDS Copyright 2002 Teledyne Analytical InstrumentsSpecific Model Information IiiSafety Messages Oxygen Analyzer Table of Contents Operation ViiMaintenance AppendixIndex Teledyne Analytical Instruments ViiiList of Figures BDS-3960 Front PanelVacuum Degassing for the BDS Oxygen Sensor List of Tables Combustible GAS Usage XiiMain Features of the Analyzer IntroductionOverview Typical ApplicationsFront Panel Operator Interface BDS-3960 Front Panel Rear Panel Equipment Interface Analog OutputsRemote Probe Range ID ContactsModel BDS 3960 Rear Panel Operational Theory IntroductionBDS Sensor Principles of OperationOxygen Analyzer Operational Theory Cross Section of the BDS Oxygen Sensor Gas Flow Rate BDS sensor output at different gas flow rateGas Pressure Temperature effectRecovery from High Level Oxygen Exposure Background Gas Compatibility Typical Purge-down Curve After Air SaturationMaintenance StabilitySample System Electronics and Signal Processing Flow DiagramOxygen Analyzer Operational Theory BDS 3960 Electronics Block Diagram Page Mounting the Analyzer InstallationUnpacking the Analyzer Oxygen Analyzer Installation Model BDS 3960 Front PanelRear Panel Connections Gas ConnectionsElectrical Connections Equipment Interface Connector Pin Arrangement Threshold Alarm Pin FunctionSystem Alarm Pin ContactCal Contact Installation Electrolyte Refill of BDS Sensor Testing the System Adding Electrolyte to the BDS SensorPowering Up the System Operation Auto Ranging onOxygen Analyzer Maintenance Analyzer applicationSystem Screen Communication Information and Calibration ParametersSetting Software Parameters Filter, Gas Factor, Tmp. Coeff Gas Factor Parameter Selection BoxTemperature Coefficient Parameter Default Values Calibration of the Analyzer Zero CalSpan Cal Alarms Function Maintenance Setting the Analog Output Ranges Range FunctionRange Options List Box Signal Output Fixed Range AnalysisSwitching The Program Back To Front Oxygen Analyzer Maintenance Maintenance Routine Maintenance Adding Water to the BDS SensorFuse Replacement Adding Water into the BDS sensorBattery Backup Replacement Removing Fuse Block from HousingReinstalling Application software to PPC Click startProgramsexplorer Click showMy DeviceCleaning TroubleshootingSymptoms Possible causes and Solutions Major Internal ComponentsCauses and solution keys Vacuum Degassing for the BDS Oxygen Sensor Oxygen Analyzer Maintenance Teledyne Analytical Instruments Specifications AppendixOperating Temperature 5-40 C Oxygen Analyzer AppendixRecommended 2-Year Spare Parts List Qty Part Number DescriptionDrawing List 19-inch Relay Rack Panel MountApplication notes Section II Physical and Chemical Data Material Safety Data SheetSection I Product Identification Section III -Physical Hazards Section IV Health Hazard DataSection VI Handling Information Alarms IndexOxygen Analyzer Index MsdsZero