Teledyne BDS-3960 Rear Panel Equipment Interface, Analog Outputs, Remote Probe, Range ID Contacts

Page 16

Introduction

BDS 3960

 

 

 

 

 

 

Access Drawer: For access to the BDS Sensor And pressure regulator. The front panel slides out when the four thumb screws are loosened. Opening the interior gives access to most circuit boards too.

1.5Rear Panel (Equipment Interface)

The rear panel, shown in Figure 1-2, contains the gas and electrical connectors for external inlets and outlets. The connectors are described briefly here and in detail in Chapter 3 Installation. Except for gas, AC power, and RS-232 communications I/O, all user connections for analog output, alarms, calibration and remote probe contacts are available through the 50 pin equipment interface connector. User connections made at the rear panel include:

Power Connection 110 VAC power source (220 VAC

optional.

Gas Inlet and Outlet One inlet and one exhaust out.

Moisture By-passAdditional vent line for condensate

Analog Outputs

0–1 VDC oxygen concentration plus

 

0-1 VDC range ID, and isolated

 

4–20 mA DC oxygen concentration

 

plus 4-20 mA DC range ID.

Alarm Connections 2 concentration alarms and 1 system alarm.

Remote Probe

Used in the BDS 3960 for

 

controlling external solenoid

 

valves only.

Remote Span/Zero Digital inputs allow external control of analyzer calibration.

Calibration Contact To notify external equipment that instrument is being calibrated and readings are not monitoring sample.•

Range ID Contacts

Four separate, dedicated, range

 

relay contacts. Low, Medium,

 

High, Cal.

Teledyne Analytical Instruments

16

Image 16
Contents Oxygen Analyzer Teledyne Analytical InstrumentsBDS Copyright 2002 Teledyne Analytical InstrumentsSpecific Model Information IiiSafety Messages Oxygen Analyzer Table of Contents Operation ViiMaintenance AppendixIndex Teledyne Analytical Instruments ViiiList of Figures BDS-3960 Front PanelVacuum Degassing for the BDS Oxygen Sensor List of Tables Combustible GAS Usage XiiMain Features of the Analyzer IntroductionOverview Typical ApplicationsFront Panel Operator Interface BDS-3960 Front Panel Rear Panel Equipment Interface Analog OutputsRemote Probe Range ID ContactsModel BDS 3960 Rear Panel Operational Theory IntroductionBDS Sensor Principles of OperationOxygen Analyzer Operational Theory Cross Section of the BDS Oxygen Sensor Gas Flow Rate BDS sensor output at different gas flow rateRecovery from High Level Oxygen Exposure Temperature effectGas Pressure Background Gas Compatibility Typical Purge-down Curve After Air SaturationMaintenance StabilitySample System Electronics and Signal Processing Flow DiagramOxygen Analyzer Operational Theory BDS 3960 Electronics Block Diagram Page Unpacking the Analyzer InstallationMounting the Analyzer Oxygen Analyzer Installation Model BDS 3960 Front PanelRear Panel Connections Gas ConnectionsElectrical Connections Equipment Interface Connector Pin Arrangement Threshold Alarm Pin FunctionSystem Alarm Pin ContactCal Contact Installation Electrolyte Refill of BDS Sensor Testing the System Adding Electrolyte to the BDS SensorPowering Up the System Operation Auto Ranging onOxygen Analyzer Maintenance Analyzer applicationSystem Screen Communication Information and Calibration ParametersSetting Software Parameters Filter, Gas Factor, Tmp. Coeff Gas Factor Parameter Selection BoxTemperature Coefficient Parameter Default Values Calibration of the Analyzer Zero CalSpan Cal Alarms Function Maintenance Setting the Analog Output Ranges Range FunctionRange Options List Box Signal Output Fixed Range AnalysisSwitching The Program Back To Front Oxygen Analyzer Maintenance Maintenance Routine Maintenance Adding Water to the BDS SensorFuse Replacement Adding Water into the BDS sensorBattery Backup Replacement Removing Fuse Block from HousingReinstalling Application software to PPC Click startProgramsexplorer Click showMy DeviceCleaning TroubleshootingSymptoms Possible causes and Solutions Major Internal ComponentsCauses and solution keys Vacuum Degassing for the BDS Oxygen Sensor Oxygen Analyzer Maintenance Teledyne Analytical Instruments Specifications AppendixOperating Temperature 5-40 C Oxygen Analyzer AppendixRecommended 2-Year Spare Parts List Qty Part Number DescriptionDrawing List 19-inch Relay Rack Panel MountApplication notes Section I Product Identification Material Safety Data SheetSection II Physical and Chemical Data Section III -Physical Hazards Section IV Health Hazard DataSection VI Handling Information Alarms IndexOxygen Analyzer Index MsdsZero