Teledyne BDS-3960 Recommended 2-Year Spare Parts List, Qty Part Number Description

Page 68

Appendix

BDS 3960

 

 

 

A-2 Recommended 2-Year Spare Parts List

Qty.

Part Number Description

1C65507B Back Panel Board

1C72914A Front Panel Board

1C72000A Preamplifier Board (Instruction)

1B71997A Main Computer Board

2

F1296

Fuse, 2A, 250V 5x20mm (European)

 

 

Slow Blow

1CP1798 50 pin D-sub interface connector

50

CP1799

Pins for CP1798 connector

1

B597

125ml wash bottle for DI water

1

B598

125ml electrolyte bottle

1

P1076

Pipet

1B72098 BDS sensor recovery kit

1

CP2237

PDA cradle

1C58750 Oxygen Scrubber

Note: Orders for replacement parts should include the part number (if available) and the model and serial number of the instrument for which the parts are intended.

Orders should be sent to:

TELEDYNE Analytical Instruments

16830 Chestnut Street

City of Industry, CA 91749-1580

Phone (626) 934-1500, Fax (626) 961-2538

Web: www.teledyne-ai.com or your local representative.

Teledyne Analytical Instruments

68

Image 68
Contents Oxygen Analyzer Teledyne Analytical InstrumentsBDS Copyright 2002 Teledyne Analytical InstrumentsSpecific Model Information IiiSafety Messages Oxygen Analyzer Table of Contents Operation ViiMaintenance AppendixIndex Teledyne Analytical Instruments ViiiList of Figures BDS-3960 Front PanelVacuum Degassing for the BDS Oxygen Sensor List of Tables Combustible GAS Usage XiiMain Features of the Analyzer IntroductionOverview Typical ApplicationsFront Panel Operator Interface BDS-3960 Front Panel Rear Panel Equipment Interface Analog OutputsRemote Probe Range ID ContactsModel BDS 3960 Rear Panel Operational Theory IntroductionBDS Sensor Principles of OperationOxygen Analyzer Operational Theory Cross Section of the BDS Oxygen Sensor Gas Flow Rate BDS sensor output at different gas flow rateGas Pressure Temperature effectRecovery from High Level Oxygen Exposure Background Gas Compatibility Typical Purge-down Curve After Air SaturationMaintenance StabilitySample System Electronics and Signal Processing Flow DiagramOxygen Analyzer Operational Theory BDS 3960 Electronics Block Diagram Page Mounting the Analyzer InstallationUnpacking the Analyzer Oxygen Analyzer Installation Model BDS 3960 Front PanelRear Panel Connections Gas ConnectionsElectrical Connections Equipment Interface Connector Pin Arrangement Threshold Alarm Pin FunctionSystem Alarm Pin ContactCal Contact Installation Electrolyte Refill of BDS Sensor Testing the System Adding Electrolyte to the BDS SensorPowering Up the System Operation Auto Ranging onOxygen Analyzer Maintenance Analyzer applicationSystem Screen Communication Information and Calibration ParametersSetting Software Parameters Filter, Gas Factor, Tmp. Coeff Gas Factor Parameter Selection BoxTemperature Coefficient Parameter Default Values Calibration of the Analyzer Zero CalSpan Cal Alarms Function Maintenance Setting the Analog Output Ranges Range FunctionRange Options List Box Signal Output Fixed Range AnalysisSwitching The Program Back To Front Oxygen Analyzer Maintenance Maintenance Routine Maintenance Adding Water to the BDS SensorFuse Replacement Adding Water into the BDS sensorBattery Backup Replacement Removing Fuse Block from HousingReinstalling Application software to PPC Click startProgramsexplorer Click showMy DeviceCleaning TroubleshootingSymptoms Possible causes and Solutions Major Internal ComponentsCauses and solution keys Vacuum Degassing for the BDS Oxygen Sensor Oxygen Analyzer Maintenance Teledyne Analytical Instruments Specifications AppendixOperating Temperature 5-40 C Oxygen Analyzer AppendixRecommended 2-Year Spare Parts List Qty Part Number DescriptionDrawing List 19-inch Relay Rack Panel MountApplication notes Section II Physical and Chemical Data Material Safety Data SheetSection I Product Identification Section III -Physical Hazards Section IV Health Hazard DataSection VI Handling Information Alarms IndexOxygen Analyzer Index MsdsZero