Emerson 3081FG instruction manual Highlights of Changes

Page 3

 

HIGHLIGHTS OF CHANGES

 

Effective June, 1998 Rev. 1.0

 

 

Page

Summary

 

 

Page 2-10

Corrected part numbers in Figure 2-9 for Flowmeter and Ref Air Set.

Page 3-4

Modified Figure 3-5 to reflect selection of additional faults.

Page 3-11

Modified paragraph 3-6a to select additional fault screens.

Page 4-4

Updated menus for O2 value, SV, TV, and 4V values.

Page 8-1

Added in replacement part numbers for Model 3081 Transmitter.

 

 

 

Effective April, 1999 Rev. 1.1

 

 

Page

Summary

 

 

Cover

Added “Model 3081FG” to manual title.

Page 1-2

Deleted 48 in. probe and Mullite probe options from Product Matrix.

Page 1-7

Deleted 48 in. probe and Mullite probe references from specifications.

Page 2-1 through 2-6 Changed probe installation mounting and insertion procedures and

 

requirements.

Page 5-1

Revised PC board stack replacement procedure.

Throughout

Changed all references to “power supply board” to read “analog board”.

 

Reformatted document in accordance with the latest style guide.

 

Effective October, 2000 Rev. 1.2

 

 

Page

Summary

 

 

Throughout

Changed all references of 38 in. (965 mm) probe to 34.625 in.

 

(880 mm).

 

 

 

Effective April, 2001 Rev. 1.3

 

 

Page

Summary

 

 

Page 2-9

Added 1st WARNING to paragraph 2-3.

Page 10-2

Added drawing 1400184.

 

 

 

Effective January, 2002 Rev. 1.4

 

 

Page

Summary

 

 

Page 8-1

Added part number for PC Board Stack Assembly.

 

 

 

Effective September, 2002 Rev. 1.5

 

 

Page

Summary

 

 

Page 1-7

Updated process temperature limits specification.

 

 

Image 3
Contents Model 3081FG Essential Instructions Highlights of Changes Page Model 3081FG Table of ContentsProper Calibration Check Gas Flow Rate List of IllustrationsModel 3081 Transmitter Terminal Block List of TablesModel 3081FG Definitions PrefaceModel 3081FG Component Checklist of Typical System Package Contents Section Description and SpecificationsCode Mounting Adapter Stack Side Product MatrixSystem Description System ConfigurationSystem Overview ScopeSystem Features Handling the Analyzer System Considerations Transmitter Typical System InstallationProbe SpecificationsOperating Load Region Lift OFF Maximum Power Supply VoltageOhms VDCInspect Section InstallationPRE-INSTALLATION Mechanical InstallationSide View Bottom View Front ViewMetal Wall Masonry Wall Stack or Duct Horizontal Probe Installation Adjusting Probe Insertion Depth Model 3081FG Installing Model 3081 Transmitter Mounting Holes Cover LockCircuit Terminal END Block TBElectrical Installation Display Positioning AssemblyModel 3081 Transmitter 4-20 mA and Signal Connections Terminal Block ConduitThermocouple CELL-WH CELL+BK Calibration Check Gas Pneumatic InstallationReference Air Package Instrument Air Reference AirFlow SET MAX Point Knob Mounting Holes Outlet ConnectionOutlet Inlet ConnectionPower UP Section Startup and OperationGeneral Proper Calibration Check Gas Flow Rate Reestablishing Proper Calibration Check GAS Flow RateMenu Tree OperationOverview DisplayProgram DiagnosticsCalcheck MenuNavigation Infrared Remote Control IRCO2 Concentration O2 Concentration Analyzer Access Code Or SecurityAnalyzer Access Code Program MenuCell T HI O2 Concentration Indicator Fault ValueO2 Concentration Upper Cell Temperature Fault Value Upper Range VALSET O2 Filter Time Reset MAX Cell TTo Reset Maximum Cell Temperature O2 Concentration Analyzer Access CodeSET HI Bottle O2 SET LO Bottle O2Concentration Parameter Range Default Model 3081 Transmitter ParametersModel 3081 Transmitter Parameters SET Code Diagnostics Menu Show FaultC mV 24. Previous Slope Previous Constant 23. Cell ImpedanceSW Build Number SW Build DateCalcheck Menu Accept LOW O2 27. in MANUAL?29. Accept LOW O2 Slope Model 3081FG Connections Hart Communicator Signal LineSection HART/AMS OverviewMethod 2, For Load Resistance 250 Ohms Analog Output Device Loop ConnectorsMenu Tree for Hart Communicator TWO-WIRE in Situ Oxygen AnalyzerHart Communicator PC OFF-LINE and ON-LINE OperationsDevice Setup From Sheet Basic Setup Detailed From Sheet Signal Condition Detailed Setup Output Hart Communicator Start CAL- Check Method Model 3081FG PC Board Stack Replacement Section Maintenance and ServiceModel 3081 Electronics Replacement Display Board ReplacementTwo-Wire In Situ Oxygen Analyzer Exploded View Oxygen Probe Replacement Oxygen Probe Terminal Block Section Troubleshooting Probe LifeIMPEDANCE, Ω Fault Indications OfresponseSpeed Thermocouple Identifying and Correcting Fault IndicationsFault 1, Open Thermocouple Fault 3, Shorted Thermocouple Fault 5, O2 Cell Open Fault 6, Cell Impedance Too High Fault 5, O2 Cell Open11. Fault 7, Reversed O2 Cell Fault 7, Reversed O2 CellModel 3081FG Section Return of Material Model 3081FG Index No Part Number Description Replacement PartsReplacement Parts List SectionModel 3081FG Section Index Model 3081FG Model 3081FG Page Section Drawings and Schematics Model 3081FG Warranty Two-Wire In Situ Oxygen Analyzer Serial no Order no