Instruction Manual |
|
|
|
|
|
|
|
| |
|
|
|
|
| Model 3081FG | ||||
September 2002 |
|
|
|
|
|
| |||
ON STARTUP | PROCESS DISPLAY |
| ON EXIT FROM |
|
|
| 1 - USER ENTERS DISPLAY | ||
OR ON RESET |
| ANY SCREEN |
|
|
| ANALYZER CODE | |||
| NORMAL |
|
|
|
| ||||
|
|
|
|
|
|
| |||
FROM ANY |
| OPERATION |
| WITHOUT EXIT |
|
|
|
|
|
SCREEN |
|
|
| EXPLICITY |
|
|
| 2 - USER ENTERS ANALYZER | |
|
|
|
|
|
|
|
| ||
|
|
|
| STATED |
|
| CAL | ACCESS CODE OR ANALYZER | |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ACCESS CODE = SECURITY | |
PROG | PROCESS DISPLAY |
| DIAG |
|
|
| DISABLE VALUE | ||
|
|
|
|
|
| ||||
| FAULTED |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
| OPERATION |
|
|
|
|
|
|
|
|
|
|
| ENTER | FAULT |
|
|
| |
CODE |
|
|
| SHOW FAULT |
| IN MANUAL? |
|
| |
|
|
|
| (IF PRESENT) |
|
| |||
| 2 |
|
|
|
|
|
|
| |
|
|
| EXIT |
|
|
|
| ||
|
|
|
|
|
|
|
| ||
555 ENTER | NEXT |
| NEXT |
| NEXT | ENTER |
| ||
DISPLAY | 1 |
|
| T/C mV |
| FAULT | ACCEPT HIGH O2 |
| |
CODE |
|
|
|
|
| ||||
|
|
|
| (IF PRESENT) |
| ||||
|
|
| EXIT |
|
|
| |||
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| ||
|
|
|
| NEXT |
|
| NEXT |
|
|
FAULT VAL |
|
|
| O2 CELL mV |
|
| ACCEPT LOW O2 | CALCHECK | |
|
|
|
|
|
| ||||
NEXT |
|
|
| NEXT |
|
| NEXT |
| MENU |
|
|
|
|
|
|
| |||
UPPER RANGE |
|
|
| CELL |
|
| SLOPE |
|
|
VAL |
|
|
| IMPEDANCE |
|
|
|
| |
|
|
|
|
|
|
|
| ||
NEXT |
|
|
| NEXT |
|
| NEXT |
|
|
CELL T HI |
|
|
| PREVIOUS |
|
| CONSTANT |
|
|
|
|
| SLOPE |
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
NEXT |
|
|
| NEXT |
|
| RESET OR EXIT | ||
RESET MAX |
|
|
| PREVIOUS | DIAGNOSTICS |
|
|
| |
CELL T |
|
|
| CONSTANT |
| MENU |
|
|
|
|
|
|
|
|
|
|
|
| |
NEXT |
|
|
| NEXT |
|
|
|
|
|
SET O2 FILTER |
| PROGRAM |
| MAX CELL T |
|
|
|
|
|
TIME |
| MENU |
|
|
|
|
|
| |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
NEXT |
|
|
| NEXT |
|
|
|
|
|
| ENTER |
|
|
|
|
|
|
|
|
TRIM 4 mA ? |
| TRIM 4 mA |
| SW VER |
|
|
|
|
|
| EXIT |
|
|
|
|
|
|
|
|
NEXT |
|
|
| NEXT |
|
|
|
|
|
| ENTER |
|
|
|
|
|
|
|
|
TRIM 20 mA ? |
| TRIM 20 mA |
| UNIT SER # |
|
|
|
|
|
NEXT | EXIT |
|
| NEXT |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
SET HI BOTTLE |
|
|
| SW BUILD |
|
|
|
|
|
O2 |
|
|
| NUMBER |
|
|
|
|
|
NEXT |
|
| NEXT | NEXT |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
SET LO BOTTLE |
|
|
| SW BUILD DATE |
|
|
|
|
|
O2 |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
NEXT |
|
|
|
|
|
|
|
|
|
SET O2 |
|
|
|
|
|
|
|
|
|
TRACKING |
|
|
|
|
|
|
|
|
|
NEXT |
|
|
|
|
|
|
|
|
|
NEXT |
|
|
|
|
|
|
|
|
|
SET CODE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 26020033 |
Figure 3-5. Model 3081 Transmitter Menu Tree
Rosemount Analytical Inc. A Division of Emerson Process Management |