Invacare TPO100B Maximum Recommended, Flowrate with 7KPA PSI Backpressure Pressure Relief, Weight

Page 16

SECTION 5—TYPICAL PRODUCT PARAMETERS

MAXIMUM RECOMMENDED

3.0 LPM

 

FLOWRATE WITH 7KPA (1.01

 

 

PSI) BACKPRESSURE:

 

 

 

 

PRESSURE RELIEF

20 psi ± 5 psi (137.8 kPa ± 34.5 kPa)

ACTIVATION:

 

 

 

 

 

MAX OUTLET PRESSURE @

12.0 psig

 

3.0 LPM CONTINUOUS:

 

 

 

 

DIMENSIONS:

16.5 in high x 11 in wide x 8 in deep (41.9 cm

(WITHOUT CART)

high x 27.9 cm wide x 20.3 cm deep)

 

 

 

WEIGHT:

< 20 lbs (9.09 kg)

 

(UNIT WITHOUT CART)

 

 

 

 

 

BATTERY DURATION:

Pulse Mode

Continuous Mode

(TIMES ARE APPROXIMATE)

 

 

Setting 1 = 4.5 hrs

Setting 0.5 LPM = 4.5

 

 

 

hrs

 

 

 

 

Setting 2 = 3.5 hrs

Setting 1 LPM = 3.5 hrs

 

 

 

 

Setting 3 = 3.0 hrs

Setting 2 LPM = 2.5 hrs

 

 

 

 

Setting 4 = 2.5 hrs

Setting 3 LPM = 1.5 hr

 

 

 

 

Setting 5 = 2.5 hrs

 

 

 

 

BATTERY RECHARGE TIME:

5 hours

 

 

Recharge time increases if battery is charging

 

while unit is running.

 

 

 

 

HUMIDITY RANGE:

 

 

OPERATING HUMIDITY:

15% to 60% non condensing

TRANSPORT AND STORAGE:

Up to 95% non condensing

 

 

 

STANDARD TEMPERATURE

 

 

RANGE

 

 

(ALL POWER SOURCES)

 

 

OPERATING TEMPERATURE:

41°F to 95°F (5°C to 35°C)

TRANSPORT AND STORAGE

 

 

TEMPERATURE:

-2°F to 140°F (-20°C to 60°C)

 

 

 

EXTENDED TEMPERATURE

 

 

RANGE:

 

 

(USING AC OR DC POWER)

 

 

OPERATING TEMPERATURE:

95°F to 104° (35°C to 40°C)

AC SUPPLY:

Unlimited use all settings, all modes

DC SUPPLY:

Unlimited use all settings with pulse mode

 

Limited to 2.0 LPM, or less, with continuous

 

mode

 

 

 

 

Invacare SOLO2

16

Part No 1156872

Image 16
Contents Invacare SOLO2 Transportable Oxygen Concentrator Accessories Warning Table of Contents Special Notes Special Notes Disposal of Equipment and Accessories General Guidelines Operating Information General Guidelines Radio Frequency Interference MaintenancePolarized Plug Instruction Packaging and Handling UnpackingInspection StorageTechnical Description Features REDTypical Product Parameters No AP/APGPower Input External Power Supply InputConserver Trigger Delay SettingsLPM Continuous Dimensions WeightBattery Duration Battery Recharge TimeRegulatory Listing Operating Instructions LocationRecommendations for Optimal Performance FiltersPowering the Transportable Oxygen Concentrator Detail a Battery Module Detail B DC Power Cable Detail C AC Power AdapterCharging the Battery Installing the Battery ModuleBattery Time Management Checking Battery Charge Level Prolonging Battery LifeDetail a Connecting/Positioning the Nasal CannulaDetail B Connecting the Humidifier Remove cap from bottleIndicators and Audible Alarm Detail a Detail BControl/Adjustment Buttons LCD Displays Mode & Flow Adjustment Screen Typical Warning Screen Typical Alarm Screen Invacare SOLO2 Detail a Front Panel Detail B LCD Display IconsUsing the SOLO2 Transportable Oxygen Concentrator Cabinet CLEANING, CARE, and MaintenanceAir Intake Filter Cleaning the Cannula Cleaning the HumidifierPreventative Maintenance Record Transportable Oxygen ConcentratorTroubleshooting Guide TroubleshootingSymptom Probable Cause Solution Unit is Beeping with no Lights or DisplayDescription Solutions LCD Display IndicatorsAcknowledgement Required Double audible beep every 15 sec Turn unit Off. Wait one minute, then Move unit to warmer, or cooler Troubleshooting Guide Ten audible beeps every 10 sec Ten audible beeps every 10 sec RED indicator Flashing Fast Continuous audible beep every half Troubleshooting Guide Make sure that car boat or motor Optional Accessories Limited Warranty Limited Warranty European Contacts European Contacts USA EC REP