Model DO-03/04
Dissolved Oxygen Measurement System with Air Blast Cleaner
Essential Instructions
Page
Section Title
Model DO-03/04 Measuring System
List of Tables
10.0
11.0
List of Figures
Section Title
Iii
Features and Benefits
Section Specifications
Output Accuracy ± 0.05 mA
Power
Repeatability ±0.05 ppm 25C
RFI/EMI EN-61326
Maximum continuous pressure 50 psig 446 kPa abs
Maximum distance between compressor and sensor
Materials of Construction
Analyzer dimensions
Enclosure dimensions
Power required selection
Description
9240048-00 Tag, stainless steel, specify marking
Model or part number Description
Section Installation
Installation
Unpacking and Inspection
Installing the air compressor enclosure
Installing the handrail mounting assembly
Assembling the pipe and pipe clamp
Installing the sensor in the washer head assembly
Attaching the pipe boom to the handrail mounting assembly
Assembling the washer head and pipe boom
Attaching the air compressor enclosure to the handrail
Installing the sensor in the washer head assembly
Section Wiring
POWER, ALARM, and Output Wiring
General
454EPH02
Section
Section
Sensor Wiring
Wiring the Oxygen Sensor
General
KEY Functions and Control
Alarm Status
Section Display and Operation
Display
Menu Tree for the 54eA Analyzer
Section Software Configuration
On following
Main Menu Calibrate See Diagnostic Variable see
Choices Factory Settings Setpoints
Program Settings List
Choices Factory Settings Configure
Choices Factory Settings
Alarm 3 setpoint
Alarm setpoints
Alarm 1 setpoint
Alarm 2 setpoint
Ranging the Outputs
MA 0.00 ppm 20 mA 20.00 ppm Output 1 12.00 mA
Test alarm 1 Open
Simulated tests
Test output
Meas units ppm
Outputs Alarms
Display
Measure Oxygen
Display contrast Timeout On
Temp units C Output 1 mA Output 2 mA
Language English Display left Display right Out
Outputs
Output 1 control
Output Measurement
Output 1 Setup
Output 1 Control
Range 4-20 mA Dampen 0 sec Hold Last Value
Changing Alarm Parameters
Configure
Alarm 1 control
Alarm 1 setup Alarm 2 control
Activate Process
Alarm 1 control
Alarm 1 setup
Alarm Low
Alarm 4 setup
Alarm Fault
Feed limit Disable
Timeout 3600 sec
Interval timer setup
Alarm 4 setup Feed limit timer
Interval timer
Timer Disable Timer Time activated Interval 24.0 hr
Temp comp Manual Temp units C
Temperature Compensation and Temperature Units
Temp comp Auto
Temp units C
Noise Reduction
60 Hz
Bar meas Auto
Bar units mm Hg
Barometric Pressure
Salinity 0.0 o/oo
Main sensor cal
Security
Noise rejection Main sensor cal Security
Analyzer Mode Priority
Condition Definitions
Action Definitions
Introduction
Section Calibration Temperature
Temperature Calibration
Adjust temp + 025.1 C
Sensor Current as a Function Dissolved Oxygen Concentration
Section Calibration Dissolved Oxygen
Zeroing the Sensor
Sensor must be in zero solution
Calibrating the Sensor in AIR
Stabilizing . . . Wait
Section
Calibrating the Sensor Against a Standard Instrument
Calibrate 8.32 ppm
Calibrating Barometric Pressure
Zero main sensor Adjust temperature
Calibrate main sensor
Standardize
Trimming the Outputs
Section Calibration Current Outputs
Replacing electrolyte solution and membrane
Section Maintenance
Replacement Parts
Cleaning the membrane
Section
Spare Parts
Power Fuse
AIR Blast Sensor Washer
Replacement Parts Location Part Number Description
Overview
Section Troubleshooting
Troubleshooting When a Fault Message is Showing
Fault message Explanation See Section
Sense line open
Temperature error low or high
High input current
Check sensor zero
Troubleshooting When no Fault Message is Showing Oxygen
Problem See Section
Zero current is too high
Possible error warning during in-process calibration
Zero reading Is unstable
Barometric pressure reading is too high or too low
Oxygen readings are too low
Process readings are erratic
Readings drift
Sensor does not respond to changes in oxygen level
Sensor Polarizing Voltage Resistance Expected current
Troubleshooting not Related to Measurement Problems
Problem Action
Simulating Inputs Dissolved Oxygen
Simulating temperature
Simulating Temperature
General
Section Return of Material
Sensor or Circuit Board only
Return of Materials Request
Warranty
Specifications subject to change without notice
Related pages
Maintenance and Troubleshooting for Runco VX-6000D
Product Specification for Black Box KV4116A
Error Message List for Brother GL100
Command data chart for BOXLIGHT CP-322i/CP-634i
Program When to use Program sequence for Miele G 5500
Installation Considerations for Niles Audio CM700DS BKT
Parts List / Liste DES Pièces / Lista DE Piezas for Powermate PM0606500
Remote Control Operation/Code List for Panasonic PT-50LCZ70
Sleep Timer Mode for Compaq f1723
How do I clean my
Delonghi DCM485 coffee maker
?
Top
Page
Image
Contents