Emerson 51-DO-04, 51-DO-03 instruction manual Spare Parts, Power Fuse

Page 58

MODEL DO-03/04

SECTION 9.0

 

MAINTENANCE

FIGURE 9-1. Sensor Parts

SPARE PARTS

 

33523-00

Electrolyte Fill Plug

 

 

9550094

O-Ring, Viton 2-014

 

 

24057-00

Membrane Retainer (smooth cap)

 

 

23501-00

Dissolved Oxygen Membrane Assembly: includes one membrane assembly and one O-ring

 

 

23502-00

Dissolved Oxygen Membrane Kit: includes 3 membrane assemblies and 3 O-rings

 

 

9210264

#1 Dissolved Oxygen Sensor Fill Solution, 4 oz (120 mL)

 

 

 

 

 

9.3 AIR COMPRESSOR (PN 9380088 115Vac or PN 9380089 220 Vac)

The air compressor has no user-serviceable parts. It does not require lubrication. Fuse sizes are shown in the table. The fuse is located below the T-shaped plastic cover next to the air compressor.

 

Power

Fuse

 

 

 

 

 

 

100-115 Vac

AGC-4, 4A, 250V

 

 

230 Vac

AGC-2, 2A, 250V

 

 

 

 

 

DANGER

Hazardous Voltage

Can cause severe injury or death. Disconnect power before servicing.

52

Image 58
Contents Dissolved Oxygen Measurement System with Air Blast Cleaner Model DO-03/04Essential Instructions Page Model DO-03/04 Measuring System Section Title10.0 List of Tables11.0 Section Title List of FiguresIii Section Specifications Features and BenefitsRFI/EMI EN-61326 PowerRepeatability ±0.05 ppm 25C Output Accuracy ± 0.05 mAMaximum distance between compressor and sensor Maximum continuous pressure 50 psig 446 kPa absMaterials of Construction Analyzer dimensions Enclosure dimensions Description Power required selection9240048-00 Tag, stainless steel, specify marking Unpacking and Inspection Section InstallationInstallation Model or part number DescriptionInstalling the handrail mounting assembly Installing the air compressor enclosureAssembling the pipe and pipe clamp Attaching the pipe boom to the handrail mounting assembly Installing the sensor in the washer head assemblyAssembling the washer head and pipe boom Attaching the air compressor enclosure to the handrail Installing the sensor in the washer head assembly POWER, ALARM, and Output Wiring Section WiringGeneral 454EPH02 Section Section Wiring the Oxygen Sensor Sensor WiringGeneral Display Alarm StatusSection Display and Operation KEY Functions and ControlSection Software Configuration Menu Tree for the 54eA AnalyzerOn following Main Menu Calibrate See Diagnostic Variable see Program Settings List Choices Factory Settings SetpointsChoices Factory Settings Configure Choices Factory Settings Alarm 2 setpoint Alarm setpointsAlarm 1 setpoint Alarm 3 setpointMA 0.00 ppm 20 mA 20.00 ppm Output 1 12.00 mA Ranging the OutputsSimulated tests Test alarm 1 OpenTest output Measure Oxygen Outputs AlarmsDisplay Meas units ppmTemp units C Output 1 mA Output 2 mA Display contrast Timeout OnLanguage English Display left Display right Out Output 1 control OutputsOutput Measurement Output 1 Control Output 1 SetupRange 4-20 mA Dampen 0 sec Hold Last Value Alarm 1 setup Alarm 2 control ConfigureAlarm 1 control Changing Alarm ParametersAlarm Low Alarm 1 controlAlarm 1 setup Activate ProcessTimeout 3600 sec Alarm FaultFeed limit Disable Alarm 4 setupTimer Disable Timer Time activated Interval 24.0 hr Alarm 4 setup Feed limit timerInterval timer Interval timer setupTemp units C Temperature Compensation and Temperature UnitsTemp comp Auto Temp comp Manual Temp units C60 Hz Noise ReductionBar units mm Hg Bar meas AutoBarometric Pressure Main sensor cal Salinity 0.0 o/ooNoise rejection Main sensor cal Security SecurityCondition Definitions Analyzer Mode PriorityAction Definitions Section Calibration Temperature IntroductionAdjust temp + 025.1 C Temperature CalibrationSection Calibration Dissolved Oxygen Sensor Current as a Function Dissolved Oxygen ConcentrationSensor must be in zero solution Zeroing the SensorStabilizing . . . Wait Calibrating the Sensor in AIRSection Calibrate 8.32 ppm Calibrating the Sensor Against a Standard InstrumentStandardize Zero main sensor Adjust temperatureCalibrate main sensor Calibrating Barometric Pressure Section Calibration Current Outputs Trimming the OutputsCleaning the membrane Section MaintenanceReplacement Parts Replacing electrolyte solution and membraneSection Power Fuse Spare PartsReplacement Parts Location Part Number Description AIR Blast Sensor WasherFault message Explanation See Section Section TroubleshootingTroubleshooting When a Fault Message is Showing OverviewCheck sensor zero Temperature error low or highHigh input current Sense line openProblem See Section Troubleshooting When no Fault Message is Showing OxygenZero current is too high Zero reading Is unstable Possible error warning during in-process calibrationBarometric pressure reading is too high or too low Sensor does not respond to changes in oxygen level Process readings are erraticReadings drift Oxygen readings are too lowSimulating Inputs Dissolved Oxygen Troubleshooting not Related to Measurement ProblemsProblem Action Sensor Polarizing Voltage Resistance Expected currentSimulating Temperature Simulating temperatureSection Return of Material GeneralReturn of Materials Request Sensor or Circuit Board onlyWarranty Specifications subject to change without notice