7. PRODUCT REQUIREMENTS

A. SUMMARY OF KEY REQUIREMENTS

SInstall unit to level subfloor.

SProvide properly dimensioned framing.

SBath can be installed in a corner. Recess, penin- sular or sunken installation is also possible.

B. PLUMBING SPECIFICATIONS

If using a rim mounted bath faucet, flexible connections between the valves and spout may be required. Confirm adequate mounting and connection space of specified faucet for your installation.

Confirm adequate support for faucet; large faucets that may be inadvertently used as a means of support are not appropriate or safe for this installation.

C. PRODUCT INSPECTION

Carefully uncrate and inspect your product for damage. Leave all materials in carton during construction to prevent damage.

NOTICE: Make sure both connections to the whirlpool pump are securely tightened.

E. ELECTRICAL REQUIREMENTS

K-1200-AC, K-1201-AC, K-1205-AC, K-1206-AC, K-1210-AC, K-1211-AC, K-1215-AC, K-1216-AC, K-1220-AC, K-1221-AC: The installation must have a Class A Ground-FaultCircuit-Interrupter (GFCI). The GFCI protects against line-to-ground shock hazard. Use a 120 V, 15 A, 60 Hz separate service for the whirlpool. Provide a separate equipment grounding conductor for the inside grounding lug. Ground must not be connected to any current-carrying conductor except at the main service breaker box.

All 50 Hz models: The installation must have an Earth Leakage Circuit Breaker (ELCB). This will provide additional protection against line-to-ground shock hazard. A 230 V, 50 Hz separate circuit that provides15 A of continuous service is required.

D. CONNECTIONS AND SERVICE ACCESS

Before installation, ensure proper access to the final connections.

NOTICE: Provide unrestricted service access to the pump. An access panel 20” W x 15” H minimum must be constructed to allow for sufficient clearance for servicing the pump or controls. The access panel must be located at the pump end of the whirlpool, through an adjoining wall.

The optional apron is removable to allow limited service access.

Kohler Co., Kohler WI

11

106548-CA(9437)

Image 11
Contents 106548- CA Copyright E1994 Kohler Co Important Safety Instructions Table of Contents Introduction ROUGHING-IN K-1200-AC, K-1201-AC ROUGHING-IN K-1205-AC, K-1206-AC ROUGHING-IN K-1210-AC, K-1211-AC ROUGHING-IN K-1215-AC, K-1216-AC ROUGHING-IN K-1220-AC, K-1221-AC Product Notices Installer Hazard NotificationProduct Requirements Clearance Requirements Installation RequirementsNEW or Replacement Installation Requirements Tools Required Materials RequiredStud Pocket Preparation Site RequirementsOLD Bath Removal Subfloor PreparationPlumbing Preparation Before Installing UnitTILING-IN Bead Installation Partially Install Bath DrainWhirlpool SET-IN Install WhirlpoolSecure Whirlpool Height AdjustmentInstall Plumbing Identify Electrical Requirements Wiring Information 120 V, 60 HZ Excluding -J1 ModelsElectrical Connections AIR Actuator Versions Field Wiring Diagram 120 V, 60 HZ -J1 Models only Locate Field Wiring Compartment 120 V, 60 HZ -J1 Models onlyConnect Control BOX 230 V, 50 HZ Field Wiring Control BOX Compartment 230 V, 50 HZWiring Information 120 V, 60 HZ Wall Timer Versions Electrical Connections Wall Timer VersionsComplete Finish Wall Water Test Whirlpool & ElectronicsOptional K-1507 Apron Installation Optional K-1515 Apron Installation Install Handles and Spout Complete InstallationCLEAN-UP After Installation Operating Sequence Confirm Proper OperationSTART-UP Whirlpool Recommended Action SymptomsTroubleshoot Whirlpool System Probable CausesKohler Co., Kohler WI 106548-CA1093 106548-CA1093 Kohler Co., Kohler WI