Kohler K-1205-AC, K-1215-AC, K-1200-AC Site Requirements, OLD Bath Removal, Subfloor Preparation

Page 13

9. SITE REQUIREMENTS

A. OLD BATH REMOVAL

Disconnect the drain at the trap. Remove old wall material. Slip boards under old bath feet to protect floor and slide old bath out of recess as illustrated.

B. SUBFLOOR PREPARATION

Check flooring under the bath and repair if necessary. Make sure that the subfloor is level. Seal subfloor to reduce the risk of water damage.

C. STUD POCKET PREPARATION

Construct a recess designed for your particular installation. Framing is of 2 x 4 construction. Make sure you allow for access to the pump or power panel in the event the unit requires service. When constructing framing allow for thickness of sub and finished wall materials.

If an apron wall without a ledge is desired, the finished apron wall surface must be 1/32” under the bath rim.

Bath can be installed in a corner. Recess, peninsular or sunken installation is also possible. Possible studding arrangements are illustrated in 1. through 2. below; modifications may be needed for other types of construction.

1.Sunken Installation: For sunken installation, refer to Roughing-In notes located in Roughing-In section beginning on page 5 for cut-out detail. Make sure the bath is supported by the supporting blocks at the bottom of the bath.

Old Bath

Floor

 

 

Protection

 

Boards

 

 

 

 

 

 

 

 

Kohler Co., Kohler WI

13

106548-CA(9437)

Image 13
Contents 106548- CA Copyright E1994 Kohler Co Important Safety Instructions Table of Contents Introduction ROUGHING-IN K-1200-AC, K-1201-AC ROUGHING-IN K-1205-AC, K-1206-AC ROUGHING-IN K-1210-AC, K-1211-AC ROUGHING-IN K-1215-AC, K-1216-AC ROUGHING-IN K-1220-AC, K-1221-AC Product Notices Installer Hazard NotificationProduct Requirements NEW or Replacement Installation Requirements Installation RequirementsTools Required Materials Required Clearance RequirementsOLD Bath Removal Site RequirementsSubfloor Preparation Stud Pocket PreparationTILING-IN Bead Installation Before Installing UnitPartially Install Bath Drain Plumbing PreparationWhirlpool SET-IN Install WhirlpoolInstall Plumbing Height AdjustmentSecure Whirlpool Electrical Connections AIR Actuator Versions Wiring Information 120 V, 60 HZ Excluding -J1 ModelsIdentify Electrical Requirements Field Wiring Diagram 120 V, 60 HZ -J1 Models only Locate Field Wiring Compartment 120 V, 60 HZ -J1 Models onlyConnect Control BOX 230 V, 50 HZ Field Wiring Control BOX Compartment 230 V, 50 HZWiring Information 120 V, 60 HZ Wall Timer Versions Electrical Connections Wall Timer VersionsComplete Finish Wall Water Test Whirlpool & ElectronicsOptional K-1507 Apron Installation Optional K-1515 Apron Installation CLEAN-UP After Installation Complete InstallationInstall Handles and Spout START-UP Whirlpool Confirm Proper OperationOperating Sequence Troubleshoot Whirlpool System SymptomsProbable Causes Recommended ActionKohler Co., Kohler WI 106548-CA1093 106548-CA1093 Kohler Co., Kohler WI