20. CONFIRM PROPER OPERATION

A. START-UP WHIRLPOOL

Refer to Important Safety Instructions on page 2 before operating this whirlpool.

Please perform the following so that the owner may safely receive the benefits of whirlpool bathing.

1.Rotate jets so they are facing down toward basin.

2.Fill the whirlpool bath to a water level at least 2” above the top of the highest jet.

Water temperature in the whirlpool should not exceed 104_F (40_C).

Water Line

Bath

2” Minimum

Wall

 

 

Jet Trim

B. OPERATING SEQUENCE

Refer to chart for proper operating sequence.

1.Turn on the whirlpool jets. Adjust each jet for optimum air/water mixture.

2.A built-in timer automatically stops the motor after 20 minutes of operation.

TO

METHOD

OBSERVE

Turn on whirl-

 

 

 

pool massage.

 

 

 

Add air to whirl-

Reduce

Add

 

pool action, rotate

Air

 

Air

 

flange counter-

 

 

clockwise. To

 

 

 

reduce air, turn

 

 

 

clockwise.

 

 

 

Shut off whirlpool.

 

 

 

Restart whirlpool

 

 

 

after 20 minute

 

 

 

cycle is com-

 

 

 

plete.

 

 

 

Kohler Co., Kohler WI

25

106548-CA(9437)

Image 25
Contents 106548- CA Copyright E1994 Kohler Co Important Safety Instructions Table of Contents Introduction ROUGHING-IN K-1200-AC, K-1201-AC ROUGHING-IN K-1205-AC, K-1206-AC ROUGHING-IN K-1210-AC, K-1211-AC ROUGHING-IN K-1215-AC, K-1216-AC ROUGHING-IN K-1220-AC, K-1221-AC Product Notices Installer Hazard NotificationProduct Requirements NEW or Replacement Installation Requirements Installation RequirementsTools Required Materials Required Clearance RequirementsOLD Bath Removal Site RequirementsSubfloor Preparation Stud Pocket PreparationTILING-IN Bead Installation Before Installing UnitPartially Install Bath Drain Plumbing PreparationWhirlpool SET-IN Install WhirlpoolInstall Plumbing Height AdjustmentSecure Whirlpool Electrical Connections AIR Actuator Versions Wiring Information 120 V, 60 HZ Excluding -J1 ModelsIdentify Electrical Requirements Field Wiring Diagram 120 V, 60 HZ -J1 Models only Locate Field Wiring Compartment 120 V, 60 HZ -J1 Models onlyConnect Control BOX 230 V, 50 HZ Field Wiring Control BOX Compartment 230 V, 50 HZWiring Information 120 V, 60 HZ Wall Timer Versions Electrical Connections Wall Timer VersionsComplete Finish Wall Water Test Whirlpool & ElectronicsOptional K-1507 Apron Installation Optional K-1515 Apron Installation CLEAN-UP After Installation Complete InstallationInstall Handles and Spout START-UP Whirlpool Confirm Proper OperationOperating Sequence Troubleshoot Whirlpool System SymptomsProbable Causes Recommended ActionKohler Co., Kohler WI 106548-CA1093 106548-CA1093 Kohler Co., Kohler WI