B. HEIGHT ADJUSTMENT

NOTICE: Steps B. and C. are necessary for making your Kohler Whirlpool operate more quietly.

If the subfloor is level, no adjustment is necessary; proceed to Step C. If the subfloor is not level, shim beneath pump bracket (plywood is recommended). Do not change the elevation of the pump relative to the whirlpool bath since this may affect performance. Use a 5 x 7 (minimum) piece of plywood.

C. SECURE WHIRLPOOL

Using four 1/4” x 1” lag screws, secure pump bracket to subfloor. Predrilling is recommended.

CAUTION: Risk of product damage. Do not use the piping or pump for structural support or positioning of whirlpools.

Use a 1/2” wrench to remove the long bolt securing the bracket to the bath.

D. INSTALL PLUMBING

CAUTION: Risk of damage to whirlpool bottom and subfloor. Ensure watertight seal on bath drain connections.

1.When whirlpool is securely positioned, connect drain into trap. An access panel will simplify future maintenance.

2.Install the faucet valving and spout tee. If faucets are deck-mounted, the deck must be finished before handle trim and spout can be installed. Open hot and cold valves and check all supply connections for leaks.

3.Run water in whirlpool and check drain connection for leaks.

Drainage

Shim if necessary, using 5” x 7” (minimum)

 

Bracket

Spacer

 

Plywood

Bolt

(if required)

 

Lag Screw

 

Connect Here

106548-CA(9437)

16

Kohler Co., Kohler WI

Image 16
Contents 106548- CA Copyright E1994 Kohler Co Important Safety Instructions Table of Contents Introduction ROUGHING-IN K-1200-AC, K-1201-AC ROUGHING-IN K-1205-AC, K-1206-AC ROUGHING-IN K-1210-AC, K-1211-AC ROUGHING-IN K-1215-AC, K-1216-AC ROUGHING-IN K-1220-AC, K-1221-AC Installer Hazard Notification Product NoticesProduct Requirements Installation Requirements NEW or Replacement Installation RequirementsTools Required Materials Required Clearance RequirementsSite Requirements OLD Bath RemovalSubfloor Preparation Stud Pocket PreparationBefore Installing Unit TILING-IN Bead InstallationPartially Install Bath Drain Plumbing PreparationInstall Whirlpool Whirlpool SET-INInstall Plumbing Height AdjustmentSecure Whirlpool Electrical Connections AIR Actuator Versions Wiring Information 120 V, 60 HZ Excluding -J1 ModelsIdentify Electrical Requirements Locate Field Wiring Compartment 120 V, 60 HZ -J1 Models only Field Wiring Diagram 120 V, 60 HZ -J1 Models onlyField Wiring Control BOX Compartment 230 V, 50 HZ Connect Control BOX 230 V, 50 HZElectrical Connections Wall Timer Versions Wiring Information 120 V, 60 HZ Wall Timer VersionsWater Test Whirlpool & Electronics Complete Finish WallOptional K-1507 Apron Installation Optional K-1515 Apron Installation CLEAN-UP After Installation Complete InstallationInstall Handles and Spout START-UP Whirlpool Confirm Proper OperationOperating Sequence Symptoms Troubleshoot Whirlpool SystemProbable Causes Recommended ActionKohler Co., Kohler WI 106548-CA1093 106548-CA1093 Kohler Co., Kohler WI