Kohler K-1211-AC Electrical Connections AIR Actuator Versions, Identify Electrical Requirements

Page 17

12. ELECTRICAL CONNECTIONS - AIR ACTUATOR VERSIONS

A. IDENTIFY ELECTRICAL REQUIREMENTS

The model number is printed on a plate at the pump end of the module.

The model number identifies electrical rating. Electrical connections for each model vary.

SK-1201-AC, K-1206-AC, K-1211-AC,

K-1216-AC, K-1221-AC:

60 Hz

(Follow Step B. below.)

 

SK-1201-J1-AA, K-1201-J1-AB, K-1206-J1-AA, K-1206-J1-AB, K-1211-J1-AA, K-1211-J1-AB,

K-1216-J1-AA, K-1221-J1-AA:

60 Hz

(Follow Steps C. and D. below.)

 

SK-1201-JA-AA, K-1206-JA-AA, K-1211-JA-AA,

K-1216-JA-AA, K-1221-JA-AA:

50 Hz

(Follow Steps E. and F. below.)

 

See Electrical Requirements section on page 11 of

Product Requirements.

B. WIRING INFORMATION - 120 V, 60 HZ (EXCLUDING -J1 MODELS)

WARNING: Risk of electrical shock. To reduce the risk of electric shock, connect only to a properly grounded, grounding-type receptacle, protected by a Ground-FaultCircuit-Interrupter (GFCI). Do not remove the plug’s grounding pin. Do not use a grounding adapter.

Your Kohler Whirlpool bath is equipped with a cord and plug. All wiring of the pump and control has been completed at the factory. A licensed electrician must install a GFCI protected, 120 Volt, 15 Amp, grounded outlet. Your whirlpool may then be plugged into this outlet. No other load should be on this circuit. Locate the outlet within reach of the 36” cord.

Kohler Co., Kohler WI

17

106548-CA(9437)

Image 17
Contents 106548- CA Copyright E1994 Kohler Co Important Safety Instructions Table of Contents Introduction ROUGHING-IN K-1200-AC, K-1201-AC ROUGHING-IN K-1205-AC, K-1206-AC ROUGHING-IN K-1210-AC, K-1211-AC ROUGHING-IN K-1215-AC, K-1216-AC ROUGHING-IN K-1220-AC, K-1221-AC Product Notices Installer Hazard NotificationProduct Requirements NEW or Replacement Installation Requirements Installation RequirementsTools Required Materials Required Clearance RequirementsOLD Bath Removal Site RequirementsSubfloor Preparation Stud Pocket PreparationTILING-IN Bead Installation Before Installing UnitPartially Install Bath Drain Plumbing PreparationWhirlpool SET-IN Install WhirlpoolSecure Whirlpool Height AdjustmentInstall Plumbing Identify Electrical Requirements Wiring Information 120 V, 60 HZ Excluding -J1 ModelsElectrical Connections AIR Actuator Versions Field Wiring Diagram 120 V, 60 HZ -J1 Models only Locate Field Wiring Compartment 120 V, 60 HZ -J1 Models onlyConnect Control BOX 230 V, 50 HZ Field Wiring Control BOX Compartment 230 V, 50 HZWiring Information 120 V, 60 HZ Wall Timer Versions Electrical Connections Wall Timer VersionsComplete Finish Wall Water Test Whirlpool & ElectronicsOptional K-1507 Apron Installation Optional K-1515 Apron Installation Install Handles and Spout Complete InstallationCLEAN-UP After Installation Operating Sequence Confirm Proper OperationSTART-UP Whirlpool Troubleshoot Whirlpool System SymptomsProbable Causes Recommended ActionKohler Co., Kohler WI 106548-CA1093 106548-CA1093 Kohler Co., Kohler WI