E.FIELD WIRING CONTROL BOX COMPARTMENT - 230 V, 50 HZ
WARNING: Risk of electrical shock. Make sure the power has been disconnected before performing the following procedures. Refer to Important Safety Instructions located on page 2.
CAUTION: Risk of electrical shock. All services must have an Earth Leakage Circuit Breaker (ELCB) which will provide additional protection against
The whirlpool controls and system have been prewired at the factory. A licensed electrician should make a routine service connection to the field wiring compartment of the control box containing blue and brown wires and earth lug.
Air |
|
|
Actuator | Control | Field Wiring |
| Compartment | |
Air | Box |
|
Actuator |
|
|
Tube |
|
|
|
| Bonding |
Pump |
| (Earthing) Lug* |
|
|
*For bonding in accordance with National and Local Codes.
F.CONNECT CONTROL BOX - 230 V, 50 HZ
Connect service to the field wiring compartment of the control box. The 50 Hz model control box contains blue and brown wires and earth lug.
A 230 V, 15 A, 50 Hz dedicated circuit is required. Provide an Earth Leakage Circuit Breaker.
Provide a separate equipment earthing conductor for the inside earth lug. The earthing conductor must not be connected to any current carrying conductor. Follow local electrical codes. A 230 V, 15A, 50 Hz separate circuit is required.
Blue Neutral (Neutral)
Brown (Phase)
Wire Connectors
Earth (Ground) Lug
Earth (Ground)
Phase (Line)
Earthing Lug (for bonding in accor- dance with national and local codes)
Kohler Co., Kohler WI | 19 |