C.LOCATE FIELD WIRING COMPARTMENT - 120 V, 60 HZ (-J1 MODELS ONLY)
WARNING: Risk of electrical shock. Make sure the power has been disconnected before performing the following procedures. Refer to Important Safety Instructions located on page 2.
CAUTION: Risk of electrical shock. All services must have a Class A
A licensed electrician should make a routine service connection to the field wiring compartment of the pump containing black and white wires and ground screw.
NOTE: The electrician must supply a listed strain/relief bushing in accordance with local codes.
Remove air actuator tubing from pump by gently pulling. Next, remove the screw at the top of the pump near the strain relief bushing. Save screw. Loosen screw at bottom of pump. Remove pump cover to reveal field wiring compartment.
*For bonding in accordance with National and Local Codes.
D.FIELD WIRING DIAGRAM - 120 V, 60 HZ (-J1
MODELS ONLY)
The factory has prewired the whirlpool control system.
A 120 V, 15 A separate circuit is required. Provide a separate equipment grounding conductor for the inside grounding conductor for the inside grounding screw (14 AWG minimum). Ground must not be connected to any
Replace pump cover over field wiring compartment. Fasten screw through cover at hole near strain relief at top of pump. Tighten screw at bottom of pump. Snip off approximately 1” of air actuator tubing and reattach to pump. Make sure tubing is securely attached to pump.
Air | Field Wiring | |
Compartment | ||
Actuator | ||
| ||
| Bonding | |
Air | (Earthing) | |
Screw* | ||
Actuator | ||
Tubing |
| |
| Pump |
Green (Ground) |
|
Black (Line) | White |
(Neutral) |
To Electrician: Pro- vide enough wire to allow motor removal upon servicing.
Strain Relief Bushing
(Not Provided)
Air Actuator Tubing
Connection
18 | Kohler Co., Kohler WI |