Kohler K-1200-AC, K-1215-AC, K-1201-AC Water Test Whirlpool & Electronics, Complete Finish Wall

Page 21

14. WATER TEST WHIRLPOOL & ELECTRONICS

Check all electrical connections. Make sure both connections to the pump are securely tightened.

Fill bath to a level at least 2” above the top of the highest jet.

Operate whirlpool for 5 minutes and check all whirlpool harness (piping) connections for leaks.

For additional information on whirlpool operation, see Whirlpool Start-Up Instructions on page 25.

15. COMPLETE FINISH WALL

CAUTION: Risk of product damage. Do not support the weight of the whirlpool by the rim.

Protect whirlpool surface. Make sure the vinyl bead is attached securely to the sides being built into the wall. Cover framing and walls with gypsum wallboard.

Tape and mud drywall...seal drywall and joints under bath rim. Install finished wall material to subwall. Seal joints between the whirlpool rim and finished wall using silicone sealant.

Gypsum Wallboard Subwall

Finished Wall Material

Water-Resistant Sealant

2 x 4 Studding

Vinyl Tiling-In Bead

Bath Rim

Kohler Co., Kohler WI

21

106548-CA(9437)

Image 21
Contents 106548- CA Copyright E1994 Kohler Co Important Safety Instructions Table of Contents Introduction ROUGHING-IN K-1200-AC, K-1201-AC ROUGHING-IN K-1205-AC, K-1206-AC ROUGHING-IN K-1210-AC, K-1211-AC ROUGHING-IN K-1215-AC, K-1216-AC ROUGHING-IN K-1220-AC, K-1221-AC Product Notices Installer Hazard NotificationProduct Requirements NEW or Replacement Installation Requirements Installation RequirementsTools Required Materials Required Clearance RequirementsOLD Bath Removal Site RequirementsSubfloor Preparation Stud Pocket PreparationTILING-IN Bead Installation Before Installing UnitPartially Install Bath Drain Plumbing PreparationWhirlpool SET-IN Install WhirlpoolHeight Adjustment Install PlumbingSecure Whirlpool Wiring Information 120 V, 60 HZ Excluding -J1 Models Electrical Connections AIR Actuator VersionsIdentify Electrical Requirements Field Wiring Diagram 120 V, 60 HZ -J1 Models only Locate Field Wiring Compartment 120 V, 60 HZ -J1 Models onlyConnect Control BOX 230 V, 50 HZ Field Wiring Control BOX Compartment 230 V, 50 HZWiring Information 120 V, 60 HZ Wall Timer Versions Electrical Connections Wall Timer VersionsComplete Finish Wall Water Test Whirlpool & ElectronicsOptional K-1507 Apron Installation Optional K-1515 Apron Installation Complete Installation CLEAN-UP After InstallationInstall Handles and Spout Confirm Proper Operation START-UP WhirlpoolOperating Sequence Troubleshoot Whirlpool System SymptomsProbable Causes Recommended ActionKohler Co., Kohler WI 106548-CA1093 106548-CA1093 Kohler Co., Kohler WI